A Wavelet-Based Unified Power Quality Conditioner to Eliminate Wind Turbine Non-Ideality Consequences on Grid-Connected Photovoltaic Systems
The integration of renewable power sources with power grids presents many challenges, such as synchronization with the grid, power quality problems and so on. The shunt active power filter (SAPF) can be a solution to address the issue while suppressing the grid-end current harmonics and distortions....
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2016-05-01
|
Series: | Energies |
Subjects: | |
Online Access: | http://www.mdpi.com/1996-1073/9/6/390 |
id |
doaj-48ffbcf8adb6425f8b4774d2159f3105 |
---|---|
record_format |
Article |
spelling |
doaj-48ffbcf8adb6425f8b4774d2159f31052020-11-24T22:22:15ZengMDPI AGEnergies1996-10732016-05-019639010.3390/en9060390en9060390A Wavelet-Based Unified Power Quality Conditioner to Eliminate Wind Turbine Non-Ideality Consequences on Grid-Connected Photovoltaic SystemsBijan Rahmani0Weixing Li1Guihua Liu2Department of Electrical Engineering, Harbin Institute of Technology, Harbin 150001, ChinaDepartment of Electrical Engineering, Harbin Institute of Technology, Harbin 150001, ChinaDepartment of Electrical Engineering, Harbin Institute of Technology, Harbin 150001, ChinaThe integration of renewable power sources with power grids presents many challenges, such as synchronization with the grid, power quality problems and so on. The shunt active power filter (SAPF) can be a solution to address the issue while suppressing the grid-end current harmonics and distortions. Nonetheless, available SAPFs work somewhat unpredictably in practice. This is attributed to the dependency of the SAPF controller on nonlinear complicated equations and two distorted variables, such as load current and voltage, to produce the current reference. This condition will worsen when the plant includes wind turbines which inherently produce 3rd, 5th, 7th and 11th voltage harmonics. Moreover, the inability of the typical phase locked loop (PLL) used to synchronize the SAPF reference with the power grid also disrupts SAPF operation. This paper proposes an improved synchronous reference frame (SRF) which is equipped with a wavelet-based PLL to control the SAPF, using one variable such as load current. Firstly the fundamental positive sequence of the source voltage, obtained using a wavelet, is used as the input signal of the PLL through an orthogonal signal generator process. Then, the generated orthogonal signals are applied through the SRF-based compensation algorithm to synchronize the SAPF’s reference with power grid. To further force the remained uncompensated grid current harmonics to pass through the SAPF, an improved series filter (SF) equipped with a current harmonic suppression loop is proposed. Concurrent operation of the improved SAPF and SF is coordinated through a unified power quality conditioner (UPQC). The DC-link capacitor of the proposed UPQC, used to interconnect a photovoltaic (PV) system to the power grid, is regulated by an adaptive controller. Matlab/Simulink results confirm that the proposed wavelet-based UPQC results in purely sinusoidal grid-end currents with total harmonic distortion (THD) = 1.29%, which leads to high electrical efficiency of a grid-connected PV system.http://www.mdpi.com/1996-1073/9/6/390active series filter (SF)load-terminal voltagesynchronous reference frame (SRF) theoryphase locked loop (PLL)low–pass filter (LPF)waveletsource currentadvanced generalized theory of instantaneous power (A-GTIP) theoryunified power quality conditioner (UPQC)DC-link |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Bijan Rahmani Weixing Li Guihua Liu |
spellingShingle |
Bijan Rahmani Weixing Li Guihua Liu A Wavelet-Based Unified Power Quality Conditioner to Eliminate Wind Turbine Non-Ideality Consequences on Grid-Connected Photovoltaic Systems Energies active series filter (SF) load-terminal voltage synchronous reference frame (SRF) theory phase locked loop (PLL) low–pass filter (LPF) wavelet source current advanced generalized theory of instantaneous power (A-GTIP) theory unified power quality conditioner (UPQC) DC-link |
author_facet |
Bijan Rahmani Weixing Li Guihua Liu |
author_sort |
Bijan Rahmani |
title |
A Wavelet-Based Unified Power Quality Conditioner to Eliminate Wind Turbine Non-Ideality Consequences on Grid-Connected Photovoltaic Systems |
title_short |
A Wavelet-Based Unified Power Quality Conditioner to Eliminate Wind Turbine Non-Ideality Consequences on Grid-Connected Photovoltaic Systems |
title_full |
A Wavelet-Based Unified Power Quality Conditioner to Eliminate Wind Turbine Non-Ideality Consequences on Grid-Connected Photovoltaic Systems |
title_fullStr |
A Wavelet-Based Unified Power Quality Conditioner to Eliminate Wind Turbine Non-Ideality Consequences on Grid-Connected Photovoltaic Systems |
title_full_unstemmed |
A Wavelet-Based Unified Power Quality Conditioner to Eliminate Wind Turbine Non-Ideality Consequences on Grid-Connected Photovoltaic Systems |
title_sort |
wavelet-based unified power quality conditioner to eliminate wind turbine non-ideality consequences on grid-connected photovoltaic systems |
publisher |
MDPI AG |
series |
Energies |
issn |
1996-1073 |
publishDate |
2016-05-01 |
description |
The integration of renewable power sources with power grids presents many challenges, such as synchronization with the grid, power quality problems and so on. The shunt active power filter (SAPF) can be a solution to address the issue while suppressing the grid-end current harmonics and distortions. Nonetheless, available SAPFs work somewhat unpredictably in practice. This is attributed to the dependency of the SAPF controller on nonlinear complicated equations and two distorted variables, such as load current and voltage, to produce the current reference. This condition will worsen when the plant includes wind turbines which inherently produce 3rd, 5th, 7th and 11th voltage harmonics. Moreover, the inability of the typical phase locked loop (PLL) used to synchronize the SAPF reference with the power grid also disrupts SAPF operation. This paper proposes an improved synchronous reference frame (SRF) which is equipped with a wavelet-based PLL to control the SAPF, using one variable such as load current. Firstly the fundamental positive sequence of the source voltage, obtained using a wavelet, is used as the input signal of the PLL through an orthogonal signal generator process. Then, the generated orthogonal signals are applied through the SRF-based compensation algorithm to synchronize the SAPF’s reference with power grid. To further force the remained uncompensated grid current harmonics to pass through the SAPF, an improved series filter (SF) equipped with a current harmonic suppression loop is proposed. Concurrent operation of the improved SAPF and SF is coordinated through a unified power quality conditioner (UPQC). The DC-link capacitor of the proposed UPQC, used to interconnect a photovoltaic (PV) system to the power grid, is regulated by an adaptive controller. Matlab/Simulink results confirm that the proposed wavelet-based UPQC results in purely sinusoidal grid-end currents with total harmonic distortion (THD) = 1.29%, which leads to high electrical efficiency of a grid-connected PV system. |
topic |
active series filter (SF) load-terminal voltage synchronous reference frame (SRF) theory phase locked loop (PLL) low–pass filter (LPF) wavelet source current advanced generalized theory of instantaneous power (A-GTIP) theory unified power quality conditioner (UPQC) DC-link |
url |
http://www.mdpi.com/1996-1073/9/6/390 |
work_keys_str_mv |
AT bijanrahmani awaveletbasedunifiedpowerqualityconditionertoeliminatewindturbinenonidealityconsequencesongridconnectedphotovoltaicsystems AT weixingli awaveletbasedunifiedpowerqualityconditionertoeliminatewindturbinenonidealityconsequencesongridconnectedphotovoltaicsystems AT guihualiu awaveletbasedunifiedpowerqualityconditionertoeliminatewindturbinenonidealityconsequencesongridconnectedphotovoltaicsystems AT bijanrahmani waveletbasedunifiedpowerqualityconditionertoeliminatewindturbinenonidealityconsequencesongridconnectedphotovoltaicsystems AT weixingli waveletbasedunifiedpowerqualityconditionertoeliminatewindturbinenonidealityconsequencesongridconnectedphotovoltaicsystems AT guihualiu waveletbasedunifiedpowerqualityconditionertoeliminatewindturbinenonidealityconsequencesongridconnectedphotovoltaicsystems |
_version_ |
1725769174644424704 |