In Vivo Biocompatibility of PLGA-Polyhexylthiophene Nanofiber Scaffolds in a Rat Model

Electroactive polymers have applications in tissue engineering as a physical template for cell adhesion and carry electrical signals to improve tissue regeneration. Present study demonstrated the biocompatibility and biodegradability of poly(lactide-co-glycolide)-poly(3-hexylthiophene) (PLGA-PHT) b...

Full description

Bibliographic Details
Main Authors: Anuradha Subramanian, Uma Maheswari Krishnan, Swaminathan Sethuraman
Format: Article
Language:English
Published: Hindawi Limited 2013-01-01
Series:BioMed Research International
Online Access:http://dx.doi.org/10.1155/2013/390518
id doaj-48e6afaa0f364ddc8bb6e5a4573b97e8
record_format Article
spelling doaj-48e6afaa0f364ddc8bb6e5a4573b97e82020-11-24T22:21:38ZengHindawi LimitedBioMed Research International2314-61332314-61412013-01-01201310.1155/2013/390518390518In Vivo Biocompatibility of PLGA-Polyhexylthiophene Nanofiber Scaffolds in a Rat ModelAnuradha Subramanian0Uma Maheswari Krishnan1Swaminathan Sethuraman2Center for Nanotechnology & Advanced Biomaterials, School of Chemical & Biotechnology, SASTRA University, Thanjavur 613 401, Tamil Nadu, IndiaCenter for Nanotechnology & Advanced Biomaterials, School of Chemical & Biotechnology, SASTRA University, Thanjavur 613 401, Tamil Nadu, IndiaCenter for Nanotechnology & Advanced Biomaterials, School of Chemical & Biotechnology, SASTRA University, Thanjavur 613 401, Tamil Nadu, IndiaElectroactive polymers have applications in tissue engineering as a physical template for cell adhesion and carry electrical signals to improve tissue regeneration. Present study demonstrated the biocompatibility and biodegradability of poly(lactide-co-glycolide)-poly(3-hexylthiophene) (PLGA-PHT) blend electrospun scaffolds in a subcutaneous rat model. The biocompatibility of PLGA-undoped PHT, PLGA-doped PHT, and aligned PLGA-doped PHT nanofibers was evaluated and compared with random PLGA fibers. The animals were sacrificed at 2, 4, and 8 weeks; the surrounding tissue along with the implant was removed to evaluate biocompatibility and biodegradability by histologic analysis and GPC, respectively. Histology results demonstrated that all scaffolds except PLGA-undoped PHT showed decrease in inflammation over time. It was observed that the aligned PLGA-doped PHT fibers elicited moderate response at 2 weeks, which further reduced to a mild response over time with well-organized tissue structure and collagen deposition. The degradation of aligned nanofibers was found to be very slow when compared to random fibers. Further, there was no reduction in the molecular weight of undoped form of PHT throughout the study. These experiments revealed the biocompatibility and biodegradability of PLGA-PHT nanofibers that potentiate it to be used as a biomaterial for various applications.http://dx.doi.org/10.1155/2013/390518
collection DOAJ
language English
format Article
sources DOAJ
author Anuradha Subramanian
Uma Maheswari Krishnan
Swaminathan Sethuraman
spellingShingle Anuradha Subramanian
Uma Maheswari Krishnan
Swaminathan Sethuraman
In Vivo Biocompatibility of PLGA-Polyhexylthiophene Nanofiber Scaffolds in a Rat Model
BioMed Research International
author_facet Anuradha Subramanian
Uma Maheswari Krishnan
Swaminathan Sethuraman
author_sort Anuradha Subramanian
title In Vivo Biocompatibility of PLGA-Polyhexylthiophene Nanofiber Scaffolds in a Rat Model
title_short In Vivo Biocompatibility of PLGA-Polyhexylthiophene Nanofiber Scaffolds in a Rat Model
title_full In Vivo Biocompatibility of PLGA-Polyhexylthiophene Nanofiber Scaffolds in a Rat Model
title_fullStr In Vivo Biocompatibility of PLGA-Polyhexylthiophene Nanofiber Scaffolds in a Rat Model
title_full_unstemmed In Vivo Biocompatibility of PLGA-Polyhexylthiophene Nanofiber Scaffolds in a Rat Model
title_sort in vivo biocompatibility of plga-polyhexylthiophene nanofiber scaffolds in a rat model
publisher Hindawi Limited
series BioMed Research International
issn 2314-6133
2314-6141
publishDate 2013-01-01
description Electroactive polymers have applications in tissue engineering as a physical template for cell adhesion and carry electrical signals to improve tissue regeneration. Present study demonstrated the biocompatibility and biodegradability of poly(lactide-co-glycolide)-poly(3-hexylthiophene) (PLGA-PHT) blend electrospun scaffolds in a subcutaneous rat model. The biocompatibility of PLGA-undoped PHT, PLGA-doped PHT, and aligned PLGA-doped PHT nanofibers was evaluated and compared with random PLGA fibers. The animals were sacrificed at 2, 4, and 8 weeks; the surrounding tissue along with the implant was removed to evaluate biocompatibility and biodegradability by histologic analysis and GPC, respectively. Histology results demonstrated that all scaffolds except PLGA-undoped PHT showed decrease in inflammation over time. It was observed that the aligned PLGA-doped PHT fibers elicited moderate response at 2 weeks, which further reduced to a mild response over time with well-organized tissue structure and collagen deposition. The degradation of aligned nanofibers was found to be very slow when compared to random fibers. Further, there was no reduction in the molecular weight of undoped form of PHT throughout the study. These experiments revealed the biocompatibility and biodegradability of PLGA-PHT nanofibers that potentiate it to be used as a biomaterial for various applications.
url http://dx.doi.org/10.1155/2013/390518
work_keys_str_mv AT anuradhasubramanian invivobiocompatibilityofplgapolyhexylthiophenenanofiberscaffoldsinaratmodel
AT umamaheswarikrishnan invivobiocompatibilityofplgapolyhexylthiophenenanofiberscaffoldsinaratmodel
AT swaminathansethuraman invivobiocompatibilityofplgapolyhexylthiophenenanofiberscaffoldsinaratmodel
_version_ 1725770281290563584