Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study

Purpose: To evaluate the clinical performance and rotational stability after implantation of Eyecryl Toric monofocal IOL following cataract surgery. Methods: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria were implanted with Eyecryl Toric IOL...

Full description

Bibliographic Details
Main Authors: Sheetal Brar, Mamta Lakhana Shah, Smith Snehal Sute, Savio Pereira, Sri Ganesh
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2021-01-01
Series:Indian Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.in/article.asp?issn=0301-4738;year=2021;volume=69;issue=7;spage=1775;epage=1780;aulast=Brar
id doaj-47d0263fff8b403b842728af89a1a410
record_format Article
spelling doaj-47d0263fff8b403b842728af89a1a4102021-08-09T09:54:26ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892021-01-016971775178010.4103/ijo.IJO_3463_20Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective studySheetal BrarMamta Lakhana ShahSmith Snehal SuteSavio PereiraSri GaneshPurpose: To evaluate the clinical performance and rotational stability after implantation of Eyecryl Toric monofocal IOL following cataract surgery. Methods: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria were implanted with Eyecryl Toric IOL. All implantations were done under balanced salt solution. A marker-less system Callisto Eye (Carl Zeiss Meditec, Germany) was used to guide the intra-operative alignment of the toric IOL. Results: A total of 50 eyes from 39 patients with mean age of 68.2 ± 8.7 years were included in the study. At 12 months, 82% (41) eyes had cumulative UDVA of 20/20 or better. Post-op SE refraction accuracy was within ± 0.50 D for 94% (n = 47) eyes and refractive cylinder accuracy was within ≤0.50 D in 98% (n = 49) eyes. Average post-op rotation at 1 year was 4.06 ± 2.15 degrees. Eighty-four percent of eyes were within 5 degrees and 16% were within 6-10 degrees of intended axis. Two eyes required IOL re-positioning due to significant rotation of the toric IOL (>10 degrees), identified within the 1st week after surgery. Conclusion: Eyecryl toric IOL demonstrated the ability to achieve a significant reduction in astigmatism, improved UDVA outcomes, high levels of spectacle independence, low rates of intra-operative injector related complications and good rotational stability at 12 months post-op.http://www.ijo.in/article.asp?issn=0301-4738;year=2021;volume=69;issue=7;spage=1775;epage=1780;aulast=Brareyecrylrotational stabilitytoric iol
collection DOAJ
language English
format Article
sources DOAJ
author Sheetal Brar
Mamta Lakhana Shah
Smith Snehal Sute
Savio Pereira
Sri Ganesh
spellingShingle Sheetal Brar
Mamta Lakhana Shah
Smith Snehal Sute
Savio Pereira
Sri Ganesh
Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study
Indian Journal of Ophthalmology
eyecryl
rotational stability
toric iol
author_facet Sheetal Brar
Mamta Lakhana Shah
Smith Snehal Sute
Savio Pereira
Sri Ganesh
author_sort Sheetal Brar
title Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study
title_short Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study
title_full Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study
title_fullStr Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study
title_full_unstemmed Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study
title_sort clinical outcomes and rotational stability following implantation of eyecryl toric intraocular lens – results of a 12-months prospective study
publisher Wolters Kluwer Medknow Publications
series Indian Journal of Ophthalmology
issn 0301-4738
1998-3689
publishDate 2021-01-01
description Purpose: To evaluate the clinical performance and rotational stability after implantation of Eyecryl Toric monofocal IOL following cataract surgery. Methods: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria were implanted with Eyecryl Toric IOL. All implantations were done under balanced salt solution. A marker-less system Callisto Eye (Carl Zeiss Meditec, Germany) was used to guide the intra-operative alignment of the toric IOL. Results: A total of 50 eyes from 39 patients with mean age of 68.2 ± 8.7 years were included in the study. At 12 months, 82% (41) eyes had cumulative UDVA of 20/20 or better. Post-op SE refraction accuracy was within ± 0.50 D for 94% (n = 47) eyes and refractive cylinder accuracy was within ≤0.50 D in 98% (n = 49) eyes. Average post-op rotation at 1 year was 4.06 ± 2.15 degrees. Eighty-four percent of eyes were within 5 degrees and 16% were within 6-10 degrees of intended axis. Two eyes required IOL re-positioning due to significant rotation of the toric IOL (>10 degrees), identified within the 1st week after surgery. Conclusion: Eyecryl toric IOL demonstrated the ability to achieve a significant reduction in astigmatism, improved UDVA outcomes, high levels of spectacle independence, low rates of intra-operative injector related complications and good rotational stability at 12 months post-op.
topic eyecryl
rotational stability
toric iol
url http://www.ijo.in/article.asp?issn=0301-4738;year=2021;volume=69;issue=7;spage=1775;epage=1780;aulast=Brar
work_keys_str_mv AT sheetalbrar clinicaloutcomesandrotationalstabilityfollowingimplantationofeyecryltoricintraocularlensresultsofa12monthsprospectivestudy
AT mamtalakhanashah clinicaloutcomesandrotationalstabilityfollowingimplantationofeyecryltoricintraocularlensresultsofa12monthsprospectivestudy
AT smithsnehalsute clinicaloutcomesandrotationalstabilityfollowingimplantationofeyecryltoricintraocularlensresultsofa12monthsprospectivestudy
AT saviopereira clinicaloutcomesandrotationalstabilityfollowingimplantationofeyecryltoricintraocularlensresultsofa12monthsprospectivestudy
AT sriganesh clinicaloutcomesandrotationalstabilityfollowingimplantationofeyecryltoricintraocularlensresultsofa12monthsprospectivestudy
_version_ 1721214488978391040