Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study
Purpose: To evaluate the clinical performance and rotational stability after implantation of Eyecryl Toric monofocal IOL following cataract surgery. Methods: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria were implanted with Eyecryl Toric IOL...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2021-01-01
|
Series: | Indian Journal of Ophthalmology |
Subjects: | |
Online Access: | http://www.ijo.in/article.asp?issn=0301-4738;year=2021;volume=69;issue=7;spage=1775;epage=1780;aulast=Brar |
id |
doaj-47d0263fff8b403b842728af89a1a410 |
---|---|
record_format |
Article |
spelling |
doaj-47d0263fff8b403b842728af89a1a4102021-08-09T09:54:26ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892021-01-016971775178010.4103/ijo.IJO_3463_20Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective studySheetal BrarMamta Lakhana ShahSmith Snehal SuteSavio PereiraSri GaneshPurpose: To evaluate the clinical performance and rotational stability after implantation of Eyecryl Toric monofocal IOL following cataract surgery. Methods: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria were implanted with Eyecryl Toric IOL. All implantations were done under balanced salt solution. A marker-less system Callisto Eye (Carl Zeiss Meditec, Germany) was used to guide the intra-operative alignment of the toric IOL. Results: A total of 50 eyes from 39 patients with mean age of 68.2 ± 8.7 years were included in the study. At 12 months, 82% (41) eyes had cumulative UDVA of 20/20 or better. Post-op SE refraction accuracy was within ± 0.50 D for 94% (n = 47) eyes and refractive cylinder accuracy was within ≤0.50 D in 98% (n = 49) eyes. Average post-op rotation at 1 year was 4.06 ± 2.15 degrees. Eighty-four percent of eyes were within 5 degrees and 16% were within 6-10 degrees of intended axis. Two eyes required IOL re-positioning due to significant rotation of the toric IOL (>10 degrees), identified within the 1st week after surgery. Conclusion: Eyecryl toric IOL demonstrated the ability to achieve a significant reduction in astigmatism, improved UDVA outcomes, high levels of spectacle independence, low rates of intra-operative injector related complications and good rotational stability at 12 months post-op.http://www.ijo.in/article.asp?issn=0301-4738;year=2021;volume=69;issue=7;spage=1775;epage=1780;aulast=Brareyecrylrotational stabilitytoric iol |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sheetal Brar Mamta Lakhana Shah Smith Snehal Sute Savio Pereira Sri Ganesh |
spellingShingle |
Sheetal Brar Mamta Lakhana Shah Smith Snehal Sute Savio Pereira Sri Ganesh Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study Indian Journal of Ophthalmology eyecryl rotational stability toric iol |
author_facet |
Sheetal Brar Mamta Lakhana Shah Smith Snehal Sute Savio Pereira Sri Ganesh |
author_sort |
Sheetal Brar |
title |
Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study |
title_short |
Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study |
title_full |
Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study |
title_fullStr |
Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study |
title_full_unstemmed |
Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens – Results of a 12-months prospective study |
title_sort |
clinical outcomes and rotational stability following implantation of eyecryl toric intraocular lens – results of a 12-months prospective study |
publisher |
Wolters Kluwer Medknow Publications |
series |
Indian Journal of Ophthalmology |
issn |
0301-4738 1998-3689 |
publishDate |
2021-01-01 |
description |
Purpose: To evaluate the clinical performance and rotational stability after implantation of Eyecryl Toric monofocal IOL following cataract surgery. Methods: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria were implanted with Eyecryl Toric IOL. All implantations were done under balanced salt solution. A marker-less system Callisto Eye (Carl Zeiss Meditec, Germany) was used to guide the intra-operative alignment of the toric IOL. Results: A total of 50 eyes from 39 patients with mean age of 68.2 ± 8.7 years were included in the study. At 12 months, 82% (41) eyes had cumulative UDVA of 20/20 or better. Post-op SE refraction accuracy was within ± 0.50 D for 94% (n = 47) eyes and refractive cylinder accuracy was within ≤0.50 D in 98% (n = 49) eyes. Average post-op rotation at 1 year was 4.06 ± 2.15 degrees. Eighty-four percent of eyes were within 5 degrees and 16% were within 6-10 degrees of intended axis. Two eyes required IOL re-positioning due to significant rotation of the toric IOL (>10 degrees), identified within the 1st week after surgery. Conclusion: Eyecryl toric IOL demonstrated the ability to achieve a significant reduction in astigmatism, improved UDVA outcomes, high levels of spectacle independence, low rates of intra-operative injector related complications and good rotational stability at 12 months post-op. |
topic |
eyecryl rotational stability toric iol |
url |
http://www.ijo.in/article.asp?issn=0301-4738;year=2021;volume=69;issue=7;spage=1775;epage=1780;aulast=Brar |
work_keys_str_mv |
AT sheetalbrar clinicaloutcomesandrotationalstabilityfollowingimplantationofeyecryltoricintraocularlensresultsofa12monthsprospectivestudy AT mamtalakhanashah clinicaloutcomesandrotationalstabilityfollowingimplantationofeyecryltoricintraocularlensresultsofa12monthsprospectivestudy AT smithsnehalsute clinicaloutcomesandrotationalstabilityfollowingimplantationofeyecryltoricintraocularlensresultsofa12monthsprospectivestudy AT saviopereira clinicaloutcomesandrotationalstabilityfollowingimplantationofeyecryltoricintraocularlensresultsofa12monthsprospectivestudy AT sriganesh clinicaloutcomesandrotationalstabilityfollowingimplantationofeyecryltoricintraocularlensresultsofa12monthsprospectivestudy |
_version_ |
1721214488978391040 |