The influence of a thermal bridge in the corner of the walls on the possibility of water vapour condensation
The article presents an analysis of temperature on an internal wall surface. Simulations on the external wall corner were also carried out. It is a place where the surface temperature is lower due to the thermal bridge effect. The calculations were performed with the ADINA program used for numerical...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2018-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://doi.org/10.1051/e3sconf/20184900072 |
id |
doaj-47bc6e880c8342de8020d40a7c1e2aa5 |
---|---|
record_format |
Article |
spelling |
doaj-47bc6e880c8342de8020d40a7c1e2aa52021-02-02T08:56:41ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01490007210.1051/e3sconf/20184900072e3sconf_solina2018_00072The influence of a thermal bridge in the corner of the walls on the possibility of water vapour condensationMiąsik PrzemysławLichołai LechThe article presents an analysis of temperature on an internal wall surface. Simulations on the external wall corner were also carried out. It is a place where the surface temperature is lower due to the thermal bridge effect. The calculations were performed with the ADINA program used for numerical simulations on heat transfer through divisional structures. Finite element analysis was employed to solve the task. The calculations were performed for five case studies with different corner structures and different methods of insulation. The baseline was a wall with the heat transfer coefficient U = 0,30 W/(m2K). The reason for selecting such a coefficient for analysis was due to the fact that in most Polish buildings thermal resistance of walls results from technical norms from before January 2014. The findings of the numerical simulations were used to determine the maximum relative humidity of the internal air where water vapour condensation may occur on the internal surface of the corner. The calculations were crucial to making a qualitative assessment of the employed solutions. The findings showed that it is possible to improve the thermal functioning of a wall in the corner thanks to an additional layer of thermal insulation, for example in the form of an avant-corps, placed within the corner.https://doi.org/10.1051/e3sconf/20184900072 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Miąsik Przemysław Lichołai Lech |
spellingShingle |
Miąsik Przemysław Lichołai Lech The influence of a thermal bridge in the corner of the walls on the possibility of water vapour condensation E3S Web of Conferences |
author_facet |
Miąsik Przemysław Lichołai Lech |
author_sort |
Miąsik Przemysław |
title |
The influence of a thermal bridge in the corner of the walls on the possibility of water vapour condensation |
title_short |
The influence of a thermal bridge in the corner of the walls on the possibility of water vapour condensation |
title_full |
The influence of a thermal bridge in the corner of the walls on the possibility of water vapour condensation |
title_fullStr |
The influence of a thermal bridge in the corner of the walls on the possibility of water vapour condensation |
title_full_unstemmed |
The influence of a thermal bridge in the corner of the walls on the possibility of water vapour condensation |
title_sort |
influence of a thermal bridge in the corner of the walls on the possibility of water vapour condensation |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2018-01-01 |
description |
The article presents an analysis of temperature on an internal wall surface. Simulations on the external wall corner were also carried out. It is a place where the surface temperature is lower due to the thermal bridge effect. The calculations were performed with the ADINA program used for numerical simulations on heat transfer through divisional structures. Finite element analysis was employed to solve the task. The calculations were performed for five case studies with different corner structures and different methods of insulation. The baseline was a wall with the heat transfer coefficient U = 0,30 W/(m2K). The reason for selecting such a coefficient for analysis was due to the fact that in most Polish buildings thermal resistance of walls results from technical norms from before January 2014. The findings of the numerical simulations were used to determine the maximum relative humidity of the internal air where water vapour condensation may occur on the internal surface of the corner. The calculations were crucial to making a qualitative assessment of the employed solutions. The findings showed that it is possible to improve the thermal functioning of a wall in the corner thanks to an additional layer of thermal insulation, for example in the form of an avant-corps, placed within the corner. |
url |
https://doi.org/10.1051/e3sconf/20184900072 |
work_keys_str_mv |
AT miasikprzemysław theinfluenceofathermalbridgeinthecornerofthewallsonthepossibilityofwatervapourcondensation AT lichołailech theinfluenceofathermalbridgeinthecornerofthewallsonthepossibilityofwatervapourcondensation AT miasikprzemysław influenceofathermalbridgeinthecornerofthewallsonthepossibilityofwatervapourcondensation AT lichołailech influenceofathermalbridgeinthecornerofthewallsonthepossibilityofwatervapourcondensation |
_version_ |
1724296014045642752 |