Enhancing Modbus-RTU Communications for Smart Metering in Building Energy Management Systems
In this work, a method for detecting and correcting errors in Modbus-RTU communications is designed, implemented, and assessed in a smart metering application. This is a low-cost solution for improving communication quality in conventional Modbus-RTU architectures with copper fieldbus. It consists o...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi-Wiley
2019-01-01
|
Series: | Security and Communication Networks |
Online Access: | http://dx.doi.org/10.1155/2019/7010717 |
id |
doaj-471181c05e2f4a39b2f2e0031bc6ea6b |
---|---|
record_format |
Article |
spelling |
doaj-471181c05e2f4a39b2f2e0031bc6ea6b2020-11-25T01:27:34ZengHindawi-WileySecurity and Communication Networks1939-01141939-01222019-01-01201910.1155/2019/70107177010717Enhancing Modbus-RTU Communications for Smart Metering in Building Energy Management SystemsClaudio Urrea0Claudio Morales1Grupo de Automática, Department of Electrical Engineering, Universidad de Santiago de Chile, Santiago, ChileGrupo de Automática, Department of Electrical Engineering, Universidad de Santiago de Chile, Santiago, ChileIn this work, a method for detecting and correcting errors in Modbus-RTU communications is designed, implemented, and assessed in a smart metering application. This is a low-cost solution for improving communication quality in conventional Modbus-RTU architectures with copper fieldbus. It consists of introducing error detection and correction devices in the network segments most susceptible to errors caused by electromagnetic interference. Experimental validations were conducted and demonstrated the effectiveness of this method for isolating noisy segments in the communication bus, maintaining full compatibility with commercial devices and improving the performance of the entire network.http://dx.doi.org/10.1155/2019/7010717 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Claudio Urrea Claudio Morales |
spellingShingle |
Claudio Urrea Claudio Morales Enhancing Modbus-RTU Communications for Smart Metering in Building Energy Management Systems Security and Communication Networks |
author_facet |
Claudio Urrea Claudio Morales |
author_sort |
Claudio Urrea |
title |
Enhancing Modbus-RTU Communications for Smart Metering in Building Energy Management Systems |
title_short |
Enhancing Modbus-RTU Communications for Smart Metering in Building Energy Management Systems |
title_full |
Enhancing Modbus-RTU Communications for Smart Metering in Building Energy Management Systems |
title_fullStr |
Enhancing Modbus-RTU Communications for Smart Metering in Building Energy Management Systems |
title_full_unstemmed |
Enhancing Modbus-RTU Communications for Smart Metering in Building Energy Management Systems |
title_sort |
enhancing modbus-rtu communications for smart metering in building energy management systems |
publisher |
Hindawi-Wiley |
series |
Security and Communication Networks |
issn |
1939-0114 1939-0122 |
publishDate |
2019-01-01 |
description |
In this work, a method for detecting and correcting errors in Modbus-RTU communications is designed, implemented, and assessed in a smart metering application. This is a low-cost solution for improving communication quality in conventional Modbus-RTU architectures with copper fieldbus. It consists of introducing error detection and correction devices in the network segments most susceptible to errors caused by electromagnetic interference. Experimental validations were conducted and demonstrated the effectiveness of this method for isolating noisy segments in the communication bus, maintaining full compatibility with commercial devices and improving the performance of the entire network. |
url |
http://dx.doi.org/10.1155/2019/7010717 |
work_keys_str_mv |
AT claudiourrea enhancingmodbusrtucommunicationsforsmartmeteringinbuildingenergymanagementsystems AT claudiomorales enhancingmodbusrtucommunicationsforsmartmeteringinbuildingenergymanagementsystems |
_version_ |
1725104598506536960 |