EN Assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modeling

The dynamic modeling of the energy characteristics of building structures with the help of energy-saving double-glazed windows was carried out in the work. The influence of different variants of windows replacement on the heat energy state of a typical mass building for various glazing coefficients...

Full description

Bibliographic Details
Main Authors: N. Buyak, V. Deshko, I. Bilous, M. Gureev, O. Holubenko
Format: Article
Language:English
Published: Odessa National Academy of Food Technologies 2020-02-01
Series:Holodilʹnaâ Tehnika i Tehnologiâ
Subjects:
pmv
Online Access:https://journals.onaft.edu.ua/index.php/reftech/article/view/1656
id doaj-46e5a5532615437fafa730ddbd4d1aa1
record_format Article
spelling doaj-46e5a5532615437fafa730ddbd4d1aa12020-11-25T02:04:11ZengOdessa National Academy of Food TechnologiesHolodilʹnaâ Tehnika i Tehnologiâ0453-83072409-67922020-02-01555-628229210.15673/ret.v55i5-6.16561656EN Assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modelingN. Buyak0V. Deshko1I. Bilous2M. Gureev3O. Holubenko4National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, 37 Prosp. Peremohy av., Kyiv, 03056, UkraineNational Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, 37 Prosp. Peremohy av., Kyiv, 03056, UkraineNational Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, 37 Prosp. Peremohy av., Kyiv, 03056, UkraineNational Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, 37 Prosp. Peremohy av., Kyiv, 03056, UkraineNational Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, 37 Prosp. Peremohy av., Kyiv, 03056, UkraineThe dynamic modeling of the energy characteristics of building structures with the help of energy-saving double-glazed windows was carried out in the work. The influence of different variants of windows replacement on the heat energy state of a typical mass building for various glazing coefficients in dynamic grid models created on the basis of the Energy Plus software product was analyzed. It is found that argon-filled glass, selective-coated glass on the outer and inner glass can reduce the energy requirement for the building by 8-10% compared to the double-glazed glass without selectively coating and filling the chambers with air. The load on the heating system is significantly different for the orientations North and South. It is assumed that the coefficient of glassy glass in the orientation of the South during the off-season (autumn / spring), less heating (switched on / off later). For North and South orientations, energy-saving windows with selective coating and / or filled up with inert gas cells have a different effect, which is explained by the coefficients of solar heat transmission, which was obtained on the basis of the simulation model. In addition, current standards in Ukraine do not provide all variants of the coefficients of optical transmittance characteristics of solar heat gains. In this work, a dynamic hourly simulation of the building energy demand in heated space for representative rooms N and S oriented for different glazing coefficients and window types has been carried out. Range of PMV change, average radiating temperature and air temperature in the room for the heating period were estimated. It was established that changing windows glazing can affect the PMV to change almost two times, which indicates the need for an integrated approach to the assessment of thermal comfort. Namely, the importance of taking into account the dynamic changes in the environment parameters and possible thermo-modernization were detectedhttps://journals.onaft.edu.ua/index.php/reftech/article/view/1656energy needenergy saving windowsthermal comfortpmvmean radiant temperatureoperating temperature
collection DOAJ
language English
format Article
sources DOAJ
author N. Buyak
V. Deshko
I. Bilous
M. Gureev
O. Holubenko
spellingShingle N. Buyak
V. Deshko
I. Bilous
M. Gureev
O. Holubenko
EN Assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modeling
Holodilʹnaâ Tehnika i Tehnologiâ
energy need
energy saving windows
thermal comfort
pmv
mean radiant temperature
operating temperature
author_facet N. Buyak
V. Deshko
I. Bilous
M. Gureev
O. Holubenko
author_sort N. Buyak
title EN Assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modeling
title_short EN Assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modeling
title_full EN Assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modeling
title_fullStr EN Assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modeling
title_full_unstemmed EN Assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modeling
title_sort en assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modeling
publisher Odessa National Academy of Food Technologies
series Holodilʹnaâ Tehnika i Tehnologiâ
issn 0453-8307
2409-6792
publishDate 2020-02-01
description The dynamic modeling of the energy characteristics of building structures with the help of energy-saving double-glazed windows was carried out in the work. The influence of different variants of windows replacement on the heat energy state of a typical mass building for various glazing coefficients in dynamic grid models created on the basis of the Energy Plus software product was analyzed. It is found that argon-filled glass, selective-coated glass on the outer and inner glass can reduce the energy requirement for the building by 8-10% compared to the double-glazed glass without selectively coating and filling the chambers with air. The load on the heating system is significantly different for the orientations North and South. It is assumed that the coefficient of glassy glass in the orientation of the South during the off-season (autumn / spring), less heating (switched on / off later). For North and South orientations, energy-saving windows with selective coating and / or filled up with inert gas cells have a different effect, which is explained by the coefficients of solar heat transmission, which was obtained on the basis of the simulation model. In addition, current standards in Ukraine do not provide all variants of the coefficients of optical transmittance characteristics of solar heat gains. In this work, a dynamic hourly simulation of the building energy demand in heated space for representative rooms N and S oriented for different glazing coefficients and window types has been carried out. Range of PMV change, average radiating temperature and air temperature in the room for the heating period were estimated. It was established that changing windows glazing can affect the PMV to change almost two times, which indicates the need for an integrated approach to the assessment of thermal comfort. Namely, the importance of taking into account the dynamic changes in the environment parameters and possible thermo-modernization were detected
topic energy need
energy saving windows
thermal comfort
pmv
mean radiant temperature
operating temperature
url https://journals.onaft.edu.ua/index.php/reftech/article/view/1656
work_keys_str_mv AT nbuyak enassessmentofthewindowreplacementinfluenceonbuildingenergyconsumptionandhumanthermalcomfortonthebasisofdynamicmodeling
AT vdeshko enassessmentofthewindowreplacementinfluenceonbuildingenergyconsumptionandhumanthermalcomfortonthebasisofdynamicmodeling
AT ibilous enassessmentofthewindowreplacementinfluenceonbuildingenergyconsumptionandhumanthermalcomfortonthebasisofdynamicmodeling
AT mgureev enassessmentofthewindowreplacementinfluenceonbuildingenergyconsumptionandhumanthermalcomfortonthebasisofdynamicmodeling
AT oholubenko enassessmentofthewindowreplacementinfluenceonbuildingenergyconsumptionandhumanthermalcomfortonthebasisofdynamicmodeling
_version_ 1724943979487690752