Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures
Elastic nails made of the nickel-titanium shape memory alloy (Nitinol) have been reported to control bone modeling in animal studies. However, the mechanical stability of the Nitinol nail in the fixation of long bone fractures remains unclear. This study compared mechanical stability among nails mad...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2018-11-01
|
Series: | Materials |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1944/11/11/2159 |
id |
doaj-45e7f26f012b4bec9d3cf305f8d2e2c1 |
---|---|
record_format |
Article |
spelling |
doaj-45e7f26f012b4bec9d3cf305f8d2e2c12020-11-24T22:52:09ZengMDPI AGMaterials1996-19442018-11-011111215910.3390/ma11112159ma11112159Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone FracturesPei-Yuan Lee0Yen-Nien Chen1Jin-Jia Hu2Chih-Han Chang3Department of BioMedical Engineering, National Cheng Kung University, Tainan 70101, TaiwanDepartment of BioMedical Engineering, National Cheng Kung University, Tainan 70101, TaiwanDepartment of BioMedical Engineering, National Cheng Kung University, Tainan 70101, TaiwanDepartment of BioMedical Engineering, National Cheng Kung University, Tainan 70101, TaiwanElastic nails made of the nickel-titanium shape memory alloy (Nitinol) have been reported to control bone modeling in animal studies. However, the mechanical stability of the Nitinol nail in the fixation of long bone fractures remains unclear. This study compared mechanical stability among nails made of three materials, namely Nitinol, titanium, and stainless steel, in the fixation of long bone fractures. These three materials had identical shapes (arc length: π/2 and radius: 260 mm). A cylindrical sawbone with a 10-mm gap and fixed with two C-shaped elastic nails was used to examine the stability of the nails. A finite element (FE) model was developed based on the sawbone model. The end cap for elastic nails was not used in the sawbone test but was considered based on a constraint equation in FE simulation. The results of stability tests appeared to depend on the presence or absence of the end cap. In the sawbone test, the titanium nail yielded a higher ultimate force against the applied load than did the stainless steel and Nitinol nails before the gap completely closed; the difference in linear stiffness between the nails was nonsignificant. In FE simulation, the titanium nail produced smaller gap shortening than did stainless steel and Nitinol nails without the end cap; the difference in gap shortening between the nails was minor with the end cap. The titanium elastic nail should be a better choice in managing diaphyseal long bone fractures when the end cap is not used. For Nitinol and stainless steel nails, the end cap should be used to stop the nail from dropping out and to stabilize the fractured bone.https://www.mdpi.com/1996-1944/11/11/2159titaniumstainlessnitinoldiaphyseal fracture |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Pei-Yuan Lee Yen-Nien Chen Jin-Jia Hu Chih-Han Chang |
spellingShingle |
Pei-Yuan Lee Yen-Nien Chen Jin-Jia Hu Chih-Han Chang Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures Materials titanium stainless nitinol diaphyseal fracture |
author_facet |
Pei-Yuan Lee Yen-Nien Chen Jin-Jia Hu Chih-Han Chang |
author_sort |
Pei-Yuan Lee |
title |
Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures |
title_short |
Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures |
title_full |
Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures |
title_fullStr |
Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures |
title_full_unstemmed |
Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures |
title_sort |
comparison of mechanical stability of elastic titanium, nickel-titanium, and stainless steel nails used in the fixation of diaphyseal long bone fractures |
publisher |
MDPI AG |
series |
Materials |
issn |
1996-1944 |
publishDate |
2018-11-01 |
description |
Elastic nails made of the nickel-titanium shape memory alloy (Nitinol) have been reported to control bone modeling in animal studies. However, the mechanical stability of the Nitinol nail in the fixation of long bone fractures remains unclear. This study compared mechanical stability among nails made of three materials, namely Nitinol, titanium, and stainless steel, in the fixation of long bone fractures. These three materials had identical shapes (arc length: π/2 and radius: 260 mm). A cylindrical sawbone with a 10-mm gap and fixed with two C-shaped elastic nails was used to examine the stability of the nails. A finite element (FE) model was developed based on the sawbone model. The end cap for elastic nails was not used in the sawbone test but was considered based on a constraint equation in FE simulation. The results of stability tests appeared to depend on the presence or absence of the end cap. In the sawbone test, the titanium nail yielded a higher ultimate force against the applied load than did the stainless steel and Nitinol nails before the gap completely closed; the difference in linear stiffness between the nails was nonsignificant. In FE simulation, the titanium nail produced smaller gap shortening than did stainless steel and Nitinol nails without the end cap; the difference in gap shortening between the nails was minor with the end cap. The titanium elastic nail should be a better choice in managing diaphyseal long bone fractures when the end cap is not used. For Nitinol and stainless steel nails, the end cap should be used to stop the nail from dropping out and to stabilize the fractured bone. |
topic |
titanium stainless nitinol diaphyseal fracture |
url |
https://www.mdpi.com/1996-1944/11/11/2159 |
work_keys_str_mv |
AT peiyuanlee comparisonofmechanicalstabilityofelastictitaniumnickeltitaniumandstainlesssteelnailsusedinthefixationofdiaphyseallongbonefractures AT yennienchen comparisonofmechanicalstabilityofelastictitaniumnickeltitaniumandstainlesssteelnailsusedinthefixationofdiaphyseallongbonefractures AT jinjiahu comparisonofmechanicalstabilityofelastictitaniumnickeltitaniumandstainlesssteelnailsusedinthefixationofdiaphyseallongbonefractures AT chihhanchang comparisonofmechanicalstabilityofelastictitaniumnickeltitaniumandstainlesssteelnailsusedinthefixationofdiaphyseallongbonefractures |
_version_ |
1725666846912282624 |