Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures

Elastic nails made of the nickel-titanium shape memory alloy (Nitinol) have been reported to control bone modeling in animal studies. However, the mechanical stability of the Nitinol nail in the fixation of long bone fractures remains unclear. This study compared mechanical stability among nails mad...

Full description

Bibliographic Details
Main Authors: Pei-Yuan Lee, Yen-Nien Chen, Jin-Jia Hu, Chih-Han Chang
Format: Article
Language:English
Published: MDPI AG 2018-11-01
Series:Materials
Subjects:
Online Access:https://www.mdpi.com/1996-1944/11/11/2159
id doaj-45e7f26f012b4bec9d3cf305f8d2e2c1
record_format Article
spelling doaj-45e7f26f012b4bec9d3cf305f8d2e2c12020-11-24T22:52:09ZengMDPI AGMaterials1996-19442018-11-011111215910.3390/ma11112159ma11112159Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone FracturesPei-Yuan Lee0Yen-Nien Chen1Jin-Jia Hu2Chih-Han Chang3Department of BioMedical Engineering, National Cheng Kung University, Tainan 70101, TaiwanDepartment of BioMedical Engineering, National Cheng Kung University, Tainan 70101, TaiwanDepartment of BioMedical Engineering, National Cheng Kung University, Tainan 70101, TaiwanDepartment of BioMedical Engineering, National Cheng Kung University, Tainan 70101, TaiwanElastic nails made of the nickel-titanium shape memory alloy (Nitinol) have been reported to control bone modeling in animal studies. However, the mechanical stability of the Nitinol nail in the fixation of long bone fractures remains unclear. This study compared mechanical stability among nails made of three materials, namely Nitinol, titanium, and stainless steel, in the fixation of long bone fractures. These three materials had identical shapes (arc length: π/2 and radius: 260 mm). A cylindrical sawbone with a 10-mm gap and fixed with two C-shaped elastic nails was used to examine the stability of the nails. A finite element (FE) model was developed based on the sawbone model. The end cap for elastic nails was not used in the sawbone test but was considered based on a constraint equation in FE simulation. The results of stability tests appeared to depend on the presence or absence of the end cap. In the sawbone test, the titanium nail yielded a higher ultimate force against the applied load than did the stainless steel and Nitinol nails before the gap completely closed; the difference in linear stiffness between the nails was nonsignificant. In FE simulation, the titanium nail produced smaller gap shortening than did stainless steel and Nitinol nails without the end cap; the difference in gap shortening between the nails was minor with the end cap. The titanium elastic nail should be a better choice in managing diaphyseal long bone fractures when the end cap is not used. For Nitinol and stainless steel nails, the end cap should be used to stop the nail from dropping out and to stabilize the fractured bone.https://www.mdpi.com/1996-1944/11/11/2159titaniumstainlessnitinoldiaphyseal fracture
collection DOAJ
language English
format Article
sources DOAJ
author Pei-Yuan Lee
Yen-Nien Chen
Jin-Jia Hu
Chih-Han Chang
spellingShingle Pei-Yuan Lee
Yen-Nien Chen
Jin-Jia Hu
Chih-Han Chang
Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures
Materials
titanium
stainless
nitinol
diaphyseal fracture
author_facet Pei-Yuan Lee
Yen-Nien Chen
Jin-Jia Hu
Chih-Han Chang
author_sort Pei-Yuan Lee
title Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures
title_short Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures
title_full Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures
title_fullStr Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures
title_full_unstemmed Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures
title_sort comparison of mechanical stability of elastic titanium, nickel-titanium, and stainless steel nails used in the fixation of diaphyseal long bone fractures
publisher MDPI AG
series Materials
issn 1996-1944
publishDate 2018-11-01
description Elastic nails made of the nickel-titanium shape memory alloy (Nitinol) have been reported to control bone modeling in animal studies. However, the mechanical stability of the Nitinol nail in the fixation of long bone fractures remains unclear. This study compared mechanical stability among nails made of three materials, namely Nitinol, titanium, and stainless steel, in the fixation of long bone fractures. These three materials had identical shapes (arc length: π/2 and radius: 260 mm). A cylindrical sawbone with a 10-mm gap and fixed with two C-shaped elastic nails was used to examine the stability of the nails. A finite element (FE) model was developed based on the sawbone model. The end cap for elastic nails was not used in the sawbone test but was considered based on a constraint equation in FE simulation. The results of stability tests appeared to depend on the presence or absence of the end cap. In the sawbone test, the titanium nail yielded a higher ultimate force against the applied load than did the stainless steel and Nitinol nails before the gap completely closed; the difference in linear stiffness between the nails was nonsignificant. In FE simulation, the titanium nail produced smaller gap shortening than did stainless steel and Nitinol nails without the end cap; the difference in gap shortening between the nails was minor with the end cap. The titanium elastic nail should be a better choice in managing diaphyseal long bone fractures when the end cap is not used. For Nitinol and stainless steel nails, the end cap should be used to stop the nail from dropping out and to stabilize the fractured bone.
topic titanium
stainless
nitinol
diaphyseal fracture
url https://www.mdpi.com/1996-1944/11/11/2159
work_keys_str_mv AT peiyuanlee comparisonofmechanicalstabilityofelastictitaniumnickeltitaniumandstainlesssteelnailsusedinthefixationofdiaphyseallongbonefractures
AT yennienchen comparisonofmechanicalstabilityofelastictitaniumnickeltitaniumandstainlesssteelnailsusedinthefixationofdiaphyseallongbonefractures
AT jinjiahu comparisonofmechanicalstabilityofelastictitaniumnickeltitaniumandstainlesssteelnailsusedinthefixationofdiaphyseallongbonefractures
AT chihhanchang comparisonofmechanicalstabilityofelastictitaniumnickeltitaniumandstainlesssteelnailsusedinthefixationofdiaphyseallongbonefractures
_version_ 1725666846912282624