Usefulness of cardiac computed tomography in transcatheter closure of atrial septal defect with amplatzer septal occluder

Background: Atrial septal defect (ASD) can be closed safely by transcatheter closure with an Amplatzer septal occluder (ASO) with cardiac computed tomography (CT) being used to image and evaluate the ASD. The purpose of this study was to evaluate the characteristics of Secundum ASD by CT and to dete...

Full description

Bibliographic Details
Main Authors: Jinyoung . Song, Yang Min . Kim, Toibayeva . Aigerim
Format: Article
Language:Russian
Published: «FIRMA «SILICEA» LLC  2013-06-01
Series:Российский кардиологический журнал
Subjects:
Online Access:https://russjcardiol.elpub.ru/jour/article/view/383
id doaj-4539f5adfb99454fbedd8836e40db535
record_format Article
spelling doaj-4539f5adfb99454fbedd8836e40db5352021-07-28T14:02:18Zrus«FIRMA «SILICEA» LLC Российский кардиологический журнал1560-40712618-76202013-06-0103353910.15829/1560-4071-2013-3-35-39383Usefulness of cardiac computed tomography in transcatheter closure of atrial septal defect with amplatzer septal occluderJinyoung . Song0Yang Min . Kim1Toibayeva . Aigerim2Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of MedicineDepartment of Radiology, Sejong General HospitalDepartment of Cardiac Surgery and Intervention Cardiology, Scientific Center of Pediatrician and Children’s Surgery, KoreaBackground: Atrial septal defect (ASD) can be closed safely by transcatheter closure with an Amplatzer septal occluder (ASO) with cardiac computed tomography (CT) being used to image and evaluate the ASD. The purpose of this study was to evaluate the characteristics of Secundum ASD by CT and to determine whether cardiac CT is an alternative to balloon sizing. Methods and Results: Forty-four ASD cases were evaluated by cardiac CT. we measured the defect diameters and lengths of the rims. The patients were divided into two groups: not using a balloon sizing technique (group 1), and using a balloon sizing technique (group 2). Most ASD cases showed ellipsoid defects with 19,6±6,5 cm for the longest diameter and 15,5±5,3 for the shortest. Except for two patients, they had sufficient posterior-inferior rims. We observed that the ratios of the device size to the longest diameter and the ratios of the occluder area to the defect area measured on CT were significantly smaller in group 1 than those in group 2 (1,1±0,1 vs 1,3±0,2 and 1,6±0,3 vs 2,2±0,9). Conclusions: Cardiac CT is useful for evaluating ASDs for transcatheter closure with an ASO. It can allow the operator to select a smaller size device than when using a stretched balloon sizing technique.https://russjcardiol.elpub.ru/jour/article/view/383atrial septal defectcardiac computed tomographyamplatzer septal occluder
collection DOAJ
language Russian
format Article
sources DOAJ
author Jinyoung . Song
Yang Min . Kim
Toibayeva . Aigerim
spellingShingle Jinyoung . Song
Yang Min . Kim
Toibayeva . Aigerim
Usefulness of cardiac computed tomography in transcatheter closure of atrial septal defect with amplatzer septal occluder
Российский кардиологический журнал
atrial septal defect
cardiac computed tomography
amplatzer septal occluder
author_facet Jinyoung . Song
Yang Min . Kim
Toibayeva . Aigerim
author_sort Jinyoung . Song
title Usefulness of cardiac computed tomography in transcatheter closure of atrial septal defect with amplatzer septal occluder
title_short Usefulness of cardiac computed tomography in transcatheter closure of atrial septal defect with amplatzer septal occluder
title_full Usefulness of cardiac computed tomography in transcatheter closure of atrial septal defect with amplatzer septal occluder
title_fullStr Usefulness of cardiac computed tomography in transcatheter closure of atrial septal defect with amplatzer septal occluder
title_full_unstemmed Usefulness of cardiac computed tomography in transcatheter closure of atrial septal defect with amplatzer septal occluder
title_sort usefulness of cardiac computed tomography in transcatheter closure of atrial septal defect with amplatzer septal occluder
publisher «FIRMA «SILICEA» LLC 
series Российский кардиологический журнал
issn 1560-4071
2618-7620
publishDate 2013-06-01
description Background: Atrial septal defect (ASD) can be closed safely by transcatheter closure with an Amplatzer septal occluder (ASO) with cardiac computed tomography (CT) being used to image and evaluate the ASD. The purpose of this study was to evaluate the characteristics of Secundum ASD by CT and to determine whether cardiac CT is an alternative to balloon sizing. Methods and Results: Forty-four ASD cases were evaluated by cardiac CT. we measured the defect diameters and lengths of the rims. The patients were divided into two groups: not using a balloon sizing technique (group 1), and using a balloon sizing technique (group 2). Most ASD cases showed ellipsoid defects with 19,6±6,5 cm for the longest diameter and 15,5±5,3 for the shortest. Except for two patients, they had sufficient posterior-inferior rims. We observed that the ratios of the device size to the longest diameter and the ratios of the occluder area to the defect area measured on CT were significantly smaller in group 1 than those in group 2 (1,1±0,1 vs 1,3±0,2 and 1,6±0,3 vs 2,2±0,9). Conclusions: Cardiac CT is useful for evaluating ASDs for transcatheter closure with an ASO. It can allow the operator to select a smaller size device than when using a stretched balloon sizing technique.
topic atrial septal defect
cardiac computed tomography
amplatzer septal occluder
url https://russjcardiol.elpub.ru/jour/article/view/383
work_keys_str_mv AT jinyoungsong usefulnessofcardiaccomputedtomographyintranscatheterclosureofatrialseptaldefectwithamplatzerseptaloccluder
AT yangminkim usefulnessofcardiaccomputedtomographyintranscatheterclosureofatrialseptaldefectwithamplatzerseptaloccluder
AT toibayevaaigerim usefulnessofcardiaccomputedtomographyintranscatheterclosureofatrialseptaldefectwithamplatzerseptaloccluder
_version_ 1721269423958917120