Testing and diagnosis of the cause of increased vibration of the fan plant's support structure
This paper presents a procedure of determining the causes of increased vibration of a fan plant and its support structure in the PUC 'Subotička toplana'. Excessive vibrations were observed following the installation of the frequency converter, thus a methodological approach of testing-anal...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of civil engineering, Subotica
2015-01-01
|
Series: | Zbornik Radova Građevinskog Fakulteta |
Subjects: | |
Online Access: | http://scindeks-clanci.ceon.rs/data/pdf/0352-6852/2015/0352-68521528035V.pdf |
id |
doaj-44ce0762a6d04c40afc30fc6f9b206f1 |
---|---|
record_format |
Article |
spelling |
doaj-44ce0762a6d04c40afc30fc6f9b206f12020-11-24T23:07:10ZengFaculty of civil engineering, SuboticaZbornik Radova Građevinskog Fakulteta0352-68522334-95732015-01-0120152835410352-68521528035VTesting and diagnosis of the cause of increased vibration of the fan plant's support structureVarju Đerđ0Tadić Ljiljana1University of Novi Sad, Faculty of Civil Engineering, Subotica, SerbiaUniversity of Novi Sad, Faculty of Civil Engineering, Subotica, SerbiaThis paper presents a procedure of determining the causes of increased vibration of a fan plant and its support structure in the PUC 'Subotička toplana'. Excessive vibrations were observed following the installation of the frequency converter, thus a methodological approach of testing-analysis-diagnosis has been applied. Based on the definition of the causes of this problem, the paper also suggests possible repair procedures.http://scindeks-clanci.ceon.rs/data/pdf/0352-6852/2015/0352-68521528035V.pdfvibration analysissupport structurevibration frequency spectrashock test |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Varju Đerđ Tadić Ljiljana |
spellingShingle |
Varju Đerđ Tadić Ljiljana Testing and diagnosis of the cause of increased vibration of the fan plant's support structure Zbornik Radova Građevinskog Fakulteta vibration analysis support structure vibration frequency spectra shock test |
author_facet |
Varju Đerđ Tadić Ljiljana |
author_sort |
Varju Đerđ |
title |
Testing and diagnosis of the cause of increased vibration of the fan plant's support structure |
title_short |
Testing and diagnosis of the cause of increased vibration of the fan plant's support structure |
title_full |
Testing and diagnosis of the cause of increased vibration of the fan plant's support structure |
title_fullStr |
Testing and diagnosis of the cause of increased vibration of the fan plant's support structure |
title_full_unstemmed |
Testing and diagnosis of the cause of increased vibration of the fan plant's support structure |
title_sort |
testing and diagnosis of the cause of increased vibration of the fan plant's support structure |
publisher |
Faculty of civil engineering, Subotica |
series |
Zbornik Radova Građevinskog Fakulteta |
issn |
0352-6852 2334-9573 |
publishDate |
2015-01-01 |
description |
This paper presents a procedure of determining the causes of increased vibration of a fan plant and its support structure in the PUC 'Subotička toplana'. Excessive vibrations were observed following the installation of the frequency converter, thus a methodological approach of testing-analysis-diagnosis has been applied. Based on the definition of the causes of this problem, the paper also suggests possible repair procedures. |
topic |
vibration analysis support structure vibration frequency spectra shock test |
url |
http://scindeks-clanci.ceon.rs/data/pdf/0352-6852/2015/0352-68521528035V.pdf |
work_keys_str_mv |
AT varjuđerđ testinganddiagnosisofthecauseofincreasedvibrationofthefanplantssupportstructure AT tadicljiljana testinganddiagnosisofthecauseofincreasedvibrationofthefanplantssupportstructure |
_version_ |
1725619554079473664 |