Evaluation of safety standards in operating rooms of Tehran University of Medical Sciences (TUMS) Hospitals in 2010

Background and Aim: The operating room is one of the main units in a hospital, where the most important phase of treatment is performed. Due to the physical properties, use of gases, and different electric devices in the operating room, the safety of both the patients and the staff should be conside...

Full description

Bibliographic Details
Main Authors: SMH Mousavi, H Dargahi, M Hasibi, Z Mokhtari, G Shaham
Format: Article
Language:fas
Published: Tehran University of Medical Sciences 2011-09-01
Series:پیاورد سلامت
Subjects:
Online Access:http://payavard.tums.ac.ir/article-1-73-en.html
id doaj-44b9e96e4688426a9ad527ce09af87cf
record_format Article
spelling doaj-44b9e96e4688426a9ad527ce09af87cf2021-10-02T19:15:46ZfasTehran University of Medical Sciencesپیاورد سلامت1735-81322008-26652011-09-01521017Evaluation of safety standards in operating rooms of Tehran University of Medical Sciences (TUMS) Hospitals in 2010SMH Mousavi0H Dargahi1M Hasibi2Z Mokhtari3G Shaham4 Background and Aim: The operating room is one of the main units in a hospital, where the most important phase of treatment is performed. Due to the physical properties, use of gases, and different electric devices in the operating room, the safety of both the patients and the staff should be considered carefully. This study aims to estimate the safety standards of the operating rooms in ‎Tehran University Hospitals and to provide solutions to the existing problems. Materials and Methods: This is a descriptive, cross-sectional study conducted in the operating rooms of TUMS hospitals. The research instrument was a checklist used by interviewers while observing the place. The safety standards were studied in terms of physical environment, protection against fire‎, personnel safety, patients' safety, and infection control. The data were analyzed by SPSS software. Results: The overall safety of the operating rooms of TUMS hospitals was found to be 84.9 percent. The figures for infection control and personnel safety, however, were lower. Conclusion: The operating rooms of Tehran University of Medical Sciences hospitals were studied in terms of five safety standards. Considering the physical environment, fire protection, and patient safety, they were quite safe but as to infection control they were relatively safe. However, they were found to be unsafe regarding the safety of their staff. Tehran Heart Center with an overall safety of 97.5% for its operating rooms can be considered as a model for the other TUMS treatment centers.http://payavard.tums.ac.ir/article-1-73-en.htmlsafetyoperating roomstandard
collection DOAJ
language fas
format Article
sources DOAJ
author SMH Mousavi
H Dargahi
M Hasibi
Z Mokhtari
G Shaham
spellingShingle SMH Mousavi
H Dargahi
M Hasibi
Z Mokhtari
G Shaham
Evaluation of safety standards in operating rooms of Tehran University of Medical Sciences (TUMS) Hospitals in 2010
پیاورد سلامت
safety
operating room
standard
author_facet SMH Mousavi
H Dargahi
M Hasibi
Z Mokhtari
G Shaham
author_sort SMH Mousavi
title Evaluation of safety standards in operating rooms of Tehran University of Medical Sciences (TUMS) Hospitals in 2010
title_short Evaluation of safety standards in operating rooms of Tehran University of Medical Sciences (TUMS) Hospitals in 2010
title_full Evaluation of safety standards in operating rooms of Tehran University of Medical Sciences (TUMS) Hospitals in 2010
title_fullStr Evaluation of safety standards in operating rooms of Tehran University of Medical Sciences (TUMS) Hospitals in 2010
title_full_unstemmed Evaluation of safety standards in operating rooms of Tehran University of Medical Sciences (TUMS) Hospitals in 2010
title_sort evaluation of safety standards in operating rooms of tehran university of medical sciences (tums) hospitals in 2010
publisher Tehran University of Medical Sciences
series پیاورد سلامت
issn 1735-8132
2008-2665
publishDate 2011-09-01
description Background and Aim: The operating room is one of the main units in a hospital, where the most important phase of treatment is performed. Due to the physical properties, use of gases, and different electric devices in the operating room, the safety of both the patients and the staff should be considered carefully. This study aims to estimate the safety standards of the operating rooms in ‎Tehran University Hospitals and to provide solutions to the existing problems. Materials and Methods: This is a descriptive, cross-sectional study conducted in the operating rooms of TUMS hospitals. The research instrument was a checklist used by interviewers while observing the place. The safety standards were studied in terms of physical environment, protection against fire‎, personnel safety, patients' safety, and infection control. The data were analyzed by SPSS software. Results: The overall safety of the operating rooms of TUMS hospitals was found to be 84.9 percent. The figures for infection control and personnel safety, however, were lower. Conclusion: The operating rooms of Tehran University of Medical Sciences hospitals were studied in terms of five safety standards. Considering the physical environment, fire protection, and patient safety, they were quite safe but as to infection control they were relatively safe. However, they were found to be unsafe regarding the safety of their staff. Tehran Heart Center with an overall safety of 97.5% for its operating rooms can be considered as a model for the other TUMS treatment centers.
topic safety
operating room
standard
url http://payavard.tums.ac.ir/article-1-73-en.html
work_keys_str_mv AT smhmousavi evaluationofsafetystandardsinoperatingroomsoftehranuniversityofmedicalsciencestumshospitalsin2010
AT hdargahi evaluationofsafetystandardsinoperatingroomsoftehranuniversityofmedicalsciencestumshospitalsin2010
AT mhasibi evaluationofsafetystandardsinoperatingroomsoftehranuniversityofmedicalsciencestumshospitalsin2010
AT zmokhtari evaluationofsafetystandardsinoperatingroomsoftehranuniversityofmedicalsciencestumshospitalsin2010
AT gshaham evaluationofsafetystandardsinoperatingroomsoftehranuniversityofmedicalsciencestumshospitalsin2010
_version_ 1716847578409074688