Experimental Investigation of Local Scour Protection for Cylindrical Bridge Piers Using Anti-Scour Collars
Local scour of bridge piers is one of the main threats responsible for bridge damage. Adopting scour countermeasures to protect bridge foundations from scour has become an important issue for the design and maintenance of bridges located in erodible sediment beds. This paper focuses on the protectiv...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-07-01
|
Series: | Water |
Subjects: | |
Online Access: | https://www.mdpi.com/2073-4441/11/7/1515 |
id |
doaj-445c1b4ed38c4d0e9b2af875633d940c |
---|---|
record_format |
Article |
spelling |
doaj-445c1b4ed38c4d0e9b2af875633d940c2020-11-25T01:42:51ZengMDPI AGWater2073-44412019-07-01117151510.3390/w11071515w11071515Experimental Investigation of Local Scour Protection for Cylindrical Bridge Piers Using Anti-Scour CollarsShunyi Wang0Kai Wei1Zhonghui Shen2Qiqi Xiang3Department of Bridge Engineering, Southwest Jiaotong University, Chengdu 610031, ChinaDepartment of Bridge Engineering, Southwest Jiaotong University, Chengdu 610031, ChinaDepartment of Bridge Engineering, Southwest Jiaotong University, Chengdu 610031, ChinaDepartment of Bridge Engineering, Southwest Jiaotong University, Chengdu 610031, ChinaLocal scour of bridge piers is one of the main threats responsible for bridge damage. Adopting scour countermeasures to protect bridge foundations from scour has become an important issue for the design and maintenance of bridges located in erodible sediment beds. This paper focuses on the protective effect of one active countermeasure named an “anti-scour collar” on local scour around the commonly used cylindrical bridge pier. A cylindrical pier model was set up in a current flume. River sand with a median particle size of 0.324 mm was selected and used as the sediment in the basin. A live-bed scour experimental program was carried out to study the protective effect of an anti-scour collar by comparing the local scour at a cylindrical bridge pier model with and without collar. The effects of three design parameters including collar installation height, collar external diameter and collar protection range, on the scour depth and scour development were investigated parametrically. According to the experimental results, it can be concluded that: the application of an anti-scour collar alleviates the local scour at the pier effectively; and the protection effect decreases with an increase in the collar installation height, but increases with an increase in the collar external diameter and the protection range. Design suggestions for improving the scour protective effect of the anti-scour collar are summarized and of great practical guiding significance to the development of anti-scour collars for bridge piers.https://www.mdpi.com/2073-4441/11/7/1515cylindrical pierlocal scouranti-scour collarbridgeexperimentscour protectionscour developmentoptimal design |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Shunyi Wang Kai Wei Zhonghui Shen Qiqi Xiang |
spellingShingle |
Shunyi Wang Kai Wei Zhonghui Shen Qiqi Xiang Experimental Investigation of Local Scour Protection for Cylindrical Bridge Piers Using Anti-Scour Collars Water cylindrical pier local scour anti-scour collar bridge experiment scour protection scour development optimal design |
author_facet |
Shunyi Wang Kai Wei Zhonghui Shen Qiqi Xiang |
author_sort |
Shunyi Wang |
title |
Experimental Investigation of Local Scour Protection for Cylindrical Bridge Piers Using Anti-Scour Collars |
title_short |
Experimental Investigation of Local Scour Protection for Cylindrical Bridge Piers Using Anti-Scour Collars |
title_full |
Experimental Investigation of Local Scour Protection for Cylindrical Bridge Piers Using Anti-Scour Collars |
title_fullStr |
Experimental Investigation of Local Scour Protection for Cylindrical Bridge Piers Using Anti-Scour Collars |
title_full_unstemmed |
Experimental Investigation of Local Scour Protection for Cylindrical Bridge Piers Using Anti-Scour Collars |
title_sort |
experimental investigation of local scour protection for cylindrical bridge piers using anti-scour collars |
publisher |
MDPI AG |
series |
Water |
issn |
2073-4441 |
publishDate |
2019-07-01 |
description |
Local scour of bridge piers is one of the main threats responsible for bridge damage. Adopting scour countermeasures to protect bridge foundations from scour has become an important issue for the design and maintenance of bridges located in erodible sediment beds. This paper focuses on the protective effect of one active countermeasure named an “anti-scour collar” on local scour around the commonly used cylindrical bridge pier. A cylindrical pier model was set up in a current flume. River sand with a median particle size of 0.324 mm was selected and used as the sediment in the basin. A live-bed scour experimental program was carried out to study the protective effect of an anti-scour collar by comparing the local scour at a cylindrical bridge pier model with and without collar. The effects of three design parameters including collar installation height, collar external diameter and collar protection range, on the scour depth and scour development were investigated parametrically. According to the experimental results, it can be concluded that: the application of an anti-scour collar alleviates the local scour at the pier effectively; and the protection effect decreases with an increase in the collar installation height, but increases with an increase in the collar external diameter and the protection range. Design suggestions for improving the scour protective effect of the anti-scour collar are summarized and of great practical guiding significance to the development of anti-scour collars for bridge piers. |
topic |
cylindrical pier local scour anti-scour collar bridge experiment scour protection scour development optimal design |
url |
https://www.mdpi.com/2073-4441/11/7/1515 |
work_keys_str_mv |
AT shunyiwang experimentalinvestigationoflocalscourprotectionforcylindricalbridgepiersusingantiscourcollars AT kaiwei experimentalinvestigationoflocalscourprotectionforcylindricalbridgepiersusingantiscourcollars AT zhonghuishen experimentalinvestigationoflocalscourprotectionforcylindricalbridgepiersusingantiscourcollars AT qiqixiang experimentalinvestigationoflocalscourprotectionforcylindricalbridgepiersusingantiscourcollars |
_version_ |
1725034706176573440 |