Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator

Background─While it is known that elevated baseline intracardiac repolarization lability is associated with the risk of fast ventricular tachycardia (FVT) /ventricular fibrillation (VF), the effect of its longitudinal changes on the risk of FVT/VF is unknown. Methods and Results─Near-field (NF) righ...

Full description

Bibliographic Details
Main Authors: Abhilash eGuduru, Jason eLansdown, Daniil eChernichenko, Ronald eBerger, Larisa G Tereshchenko
Format: Article
Language:English
Published: Frontiers Media S.A. 2013-08-01
Series:Frontiers in Physiology
Subjects:
Online Access:http://journal.frontiersin.org/Journal/10.3389/fphys.2013.00208/full
id doaj-4439a665b572480ea9b26fe2e617259e
record_format Article
spelling doaj-4439a665b572480ea9b26fe2e617259e2020-11-24T23:20:35ZengFrontiers Media S.A.Frontiers in Physiology1664-042X2013-08-01410.3389/fphys.2013.0020858537Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillatorAbhilash eGuduru0Jason eLansdown1Daniil eChernichenko2Ronald eBerger3Larisa G Tereshchenko4Johns Hopkins University School of MedicineJohns Hopkins University School of MedicineJohns Hopkins University School of MedicineJohns Hopkins University School of MedicineJohns Hopkins University School of MedicineBackground─While it is known that elevated baseline intracardiac repolarization lability is associated with the risk of fast ventricular tachycardia (FVT) /ventricular fibrillation (VF), the effect of its longitudinal changes on the risk of FVT/VF is unknown. Methods and Results─Near-field (NF) right ventricular (RV) intracardiac electrograms (EGMs) were recorded every 3-6 months at rest in 248 patients with structural heart disease (mean age 61.2±13.3; 185[75%] male; 162[65.3%] ischemic cardiomyopathy) and implanted cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) [201 (81%) primary prevention]. Intracardiac beat-to-beat QT variability index (QTVINF) was measured on NF RV EGM. During the first study phase (median 18 months), participants made on average 2.4 visits. Then remote follow-up was continued for an additional median period of 3 years. Average QTVINF did not change during the first year after ICD implantation (-0.342±0.603 at baseline vs. -0.262±0.552 at 6 months vs. -0.334±0.603 at 12 months); however, it decreased thereafter (-0.510±0.603 at 18 months; P=0.042). Adjusted population-averaged GEE model showed that the odds of developing FVT/VF increased by 75% for each 1 unit increase in QTVINF. (OR 1.75 [95%CI 1.05-2.92]; P=0.031). However, individual patient–specific QTVINF trends (increasing, decreasing, flat) varied from patient to patient. For a given patient, the odds of developing FVT/VF were not associated with increasing or decreasing QTVINF over time (OR 1.27; [95%CI 0.05–30.10]; P = 0.881).Conclusion─While on average the odds of FVT/VF increased with an increase in QTVINF, patient-specific longitudinal trends in QTVINF did not affect the odds of FVT/VF.http://journal.frontiersin.org/Journal/10.3389/fphys.2013.00208/fulllongitudinal analysisintracardiac electrogramsrepolarization labilityventricular tachyarrhythmiaQT variability index
collection DOAJ
language English
format Article
sources DOAJ
author Abhilash eGuduru
Jason eLansdown
Daniil eChernichenko
Ronald eBerger
Larisa G Tereshchenko
spellingShingle Abhilash eGuduru
Jason eLansdown
Daniil eChernichenko
Ronald eBerger
Larisa G Tereshchenko
Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator
Frontiers in Physiology
longitudinal analysis
intracardiac electrograms
repolarization lability
ventricular tachyarrhythmia
QT variability index
author_facet Abhilash eGuduru
Jason eLansdown
Daniil eChernichenko
Ronald eBerger
Larisa G Tereshchenko
author_sort Abhilash eGuduru
title Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator
title_short Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator
title_full Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator
title_fullStr Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator
title_full_unstemmed Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator
title_sort longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator
publisher Frontiers Media S.A.
series Frontiers in Physiology
issn 1664-042X
publishDate 2013-08-01
description Background─While it is known that elevated baseline intracardiac repolarization lability is associated with the risk of fast ventricular tachycardia (FVT) /ventricular fibrillation (VF), the effect of its longitudinal changes on the risk of FVT/VF is unknown. Methods and Results─Near-field (NF) right ventricular (RV) intracardiac electrograms (EGMs) were recorded every 3-6 months at rest in 248 patients with structural heart disease (mean age 61.2±13.3; 185[75%] male; 162[65.3%] ischemic cardiomyopathy) and implanted cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) [201 (81%) primary prevention]. Intracardiac beat-to-beat QT variability index (QTVINF) was measured on NF RV EGM. During the first study phase (median 18 months), participants made on average 2.4 visits. Then remote follow-up was continued for an additional median period of 3 years. Average QTVINF did not change during the first year after ICD implantation (-0.342±0.603 at baseline vs. -0.262±0.552 at 6 months vs. -0.334±0.603 at 12 months); however, it decreased thereafter (-0.510±0.603 at 18 months; P=0.042). Adjusted population-averaged GEE model showed that the odds of developing FVT/VF increased by 75% for each 1 unit increase in QTVINF. (OR 1.75 [95%CI 1.05-2.92]; P=0.031). However, individual patient–specific QTVINF trends (increasing, decreasing, flat) varied from patient to patient. For a given patient, the odds of developing FVT/VF were not associated with increasing or decreasing QTVINF over time (OR 1.27; [95%CI 0.05–30.10]; P = 0.881).Conclusion─While on average the odds of FVT/VF increased with an increase in QTVINF, patient-specific longitudinal trends in QTVINF did not affect the odds of FVT/VF.
topic longitudinal analysis
intracardiac electrograms
repolarization lability
ventricular tachyarrhythmia
QT variability index
url http://journal.frontiersin.org/Journal/10.3389/fphys.2013.00208/full
work_keys_str_mv AT abhilasheguduru longitudinalchangesinintracardiacrepolarizationlabilityinpatientswithimplantablecardioverterdefibrillator
AT jasonelansdown longitudinalchangesinintracardiacrepolarizationlabilityinpatientswithimplantablecardioverterdefibrillator
AT daniilechernichenko longitudinalchangesinintracardiacrepolarizationlabilityinpatientswithimplantablecardioverterdefibrillator
AT ronaldeberger longitudinalchangesinintracardiacrepolarizationlabilityinpatientswithimplantablecardioverterdefibrillator
AT larisagtereshchenko longitudinalchangesinintracardiacrepolarizationlabilityinpatientswithimplantablecardioverterdefibrillator
_version_ 1725574426547716096