Jessica E Chan, Peter A Netland Department of Ophthalmology, University of Virginia School of Medicine, Charlottesville, VA, USA Abstract: Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, co...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dove Medical Press
2015-09-01
|
Series: | Medical Devices : Evidence and Research |
Online Access: | https://www.dovepress.com/ex-press-glaucoma-filtration-device-efficacy-safety-and-predictability-peer-reviewed-article-MDER |
id |
doaj-43ded5426e1943e887f5022000fb42f2 |
---|---|
record_format |
Article |
spelling |
doaj-43ded5426e1943e887f5022000fb42f22020-11-24T22:46:52ZengDove Medical PressMedical Devices : Evidence and Research1179-14702015-09-012015default38138823507EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictabilityChan JENetlPAJessica E Chan, Peter A Netland Department of Ophthalmology, University of Virginia School of Medicine, Charlottesville, VA, USA Abstract: Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. Keywords: surgery, trabeculectomy, mitomycin C, glaucoma drainage implanthttps://www.dovepress.com/ex-press-glaucoma-filtration-device-efficacy-safety-and-predictability-peer-reviewed-article-MDER |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Chan JE Netl PA |
spellingShingle |
Chan JE Netl PA EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability Medical Devices : Evidence and Research |
author_facet |
Chan JE Netl PA |
author_sort |
Chan JE |
title |
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_short |
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_full |
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_fullStr |
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_full_unstemmed |
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_sort |
ex-press glaucoma filtration device: efficacy, safety, and predictability |
publisher |
Dove Medical Press |
series |
Medical Devices : Evidence and Research |
issn |
1179-1470 |
publishDate |
2015-09-01 |
description |
Jessica E Chan, Peter A Netland Department of Ophthalmology, University of Virginia School of Medicine, Charlottesville, VA, USA Abstract: Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. Keywords: surgery, trabeculectomy, mitomycin C, glaucoma drainage implant |
url |
https://www.dovepress.com/ex-press-glaucoma-filtration-device-efficacy-safety-and-predictability-peer-reviewed-article-MDER |
work_keys_str_mv |
AT chanje expressglaucomafiltrationdeviceefficacysafetyandpredictability AT netl expressglaucomafiltrationdeviceefficacysafetyandpredictability AT pa expressglaucomafiltrationdeviceefficacysafetyandpredictability |
_version_ |
1725683420328099840 |