Modeling and Optimization of the Drinking Water Supply Network—A System Case Study from the Czech Republic

In this study, we investigated the modelling and optimization of drinking water supply system reliability in the village of Zaben, Czech Republic. An in depth overview of the water supply network in the municipality, passport processing and accident and malfunction recording is provided based on dat...

Full description

Bibliographic Details
Main Authors: Marek Teichmann, Dagmar Kuta, Stanislav Endel, Natalie Szeligova
Format: Article
Language:English
Published: MDPI AG 2020-11-01
Series:Sustainability
Subjects:
Online Access:https://www.mdpi.com/2071-1050/12/23/9984
id doaj-43c48b6ccae0438ea5ac496f20e9516a
record_format Article
spelling doaj-43c48b6ccae0438ea5ac496f20e9516a2020-11-30T00:02:10ZengMDPI AGSustainability2071-10502020-11-01129984998410.3390/su12239984Modeling and Optimization of the Drinking Water Supply Network—A System Case Study from the Czech RepublicMarek Teichmann0Dagmar Kuta1Stanislav Endel2Natalie Szeligova3Department of Urban Engineering, Faculty of Civil Engineering, VSB—Technical University of Ostrava, 708 00 Ostrava-Poruba, Czech RepublicDepartment of Urban Engineering, Faculty of Civil Engineering, VSB—Technical University of Ostrava, 708 00 Ostrava-Poruba, Czech RepublicDepartment of Urban Engineering, Faculty of Civil Engineering, VSB—Technical University of Ostrava, 708 00 Ostrava-Poruba, Czech RepublicDepartment of Spatial Planning and the Environment, Karvina City Authority, 733 24 Karvina, Czech RepublicIn this study, we investigated the modelling and optimization of drinking water supply system reliability in the village of Zaben, Czech Republic. An in depth overview of the water supply network in the municipality, passport processing and accident and malfunction recording is provided based on data provided by the owner and operator of the water mains as well as the data collected by our own field survey. Using the data processed from accident and failure reports in addition to water main documentation, the water supply network in Zaben was evaluated according to the failure modes and effects analysis methods. Subsequently, individual water supply lines were classified based on their structural condition. In addition, a proposed plan for financing the reconstruction of the water supply mains in Zaben was created. As such, this study provides an overall assessment of the water supply network in Zaben alongside a proposed plan for the structural restoration of the water supply system, which accounts for the theoretical service life of the system and the financial resources of the owner.https://www.mdpi.com/2071-1050/12/23/9984water pipesstructural integrityfailure modes
collection DOAJ
language English
format Article
sources DOAJ
author Marek Teichmann
Dagmar Kuta
Stanislav Endel
Natalie Szeligova
spellingShingle Marek Teichmann
Dagmar Kuta
Stanislav Endel
Natalie Szeligova
Modeling and Optimization of the Drinking Water Supply Network—A System Case Study from the Czech Republic
Sustainability
water pipes
structural integrity
failure modes
author_facet Marek Teichmann
Dagmar Kuta
Stanislav Endel
Natalie Szeligova
author_sort Marek Teichmann
title Modeling and Optimization of the Drinking Water Supply Network—A System Case Study from the Czech Republic
title_short Modeling and Optimization of the Drinking Water Supply Network—A System Case Study from the Czech Republic
title_full Modeling and Optimization of the Drinking Water Supply Network—A System Case Study from the Czech Republic
title_fullStr Modeling and Optimization of the Drinking Water Supply Network—A System Case Study from the Czech Republic
title_full_unstemmed Modeling and Optimization of the Drinking Water Supply Network—A System Case Study from the Czech Republic
title_sort modeling and optimization of the drinking water supply network—a system case study from the czech republic
publisher MDPI AG
series Sustainability
issn 2071-1050
publishDate 2020-11-01
description In this study, we investigated the modelling and optimization of drinking water supply system reliability in the village of Zaben, Czech Republic. An in depth overview of the water supply network in the municipality, passport processing and accident and malfunction recording is provided based on data provided by the owner and operator of the water mains as well as the data collected by our own field survey. Using the data processed from accident and failure reports in addition to water main documentation, the water supply network in Zaben was evaluated according to the failure modes and effects analysis methods. Subsequently, individual water supply lines were classified based on their structural condition. In addition, a proposed plan for financing the reconstruction of the water supply mains in Zaben was created. As such, this study provides an overall assessment of the water supply network in Zaben alongside a proposed plan for the structural restoration of the water supply system, which accounts for the theoretical service life of the system and the financial resources of the owner.
topic water pipes
structural integrity
failure modes
url https://www.mdpi.com/2071-1050/12/23/9984
work_keys_str_mv AT marekteichmann modelingandoptimizationofthedrinkingwatersupplynetworkasystemcasestudyfromtheczechrepublic
AT dagmarkuta modelingandoptimizationofthedrinkingwatersupplynetworkasystemcasestudyfromtheczechrepublic
AT stanislavendel modelingandoptimizationofthedrinkingwatersupplynetworkasystemcasestudyfromtheczechrepublic
AT natalieszeligova modelingandoptimizationofthedrinkingwatersupplynetworkasystemcasestudyfromtheczechrepublic
_version_ 1724411759343697920