Calibration of Gas-Metering Constrictions
To extend the range of usefulness of a water calibrated metering constriction in the field of gas flow measurement, a method is described for determining the expansion coefficient (∈) which does not involve measurement of gas flow rate, while the precision of the method is such as to achieve accurac...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
1974-01-01
|
Series: | Measurement + Control |
Online Access: | https://doi.org/10.1177/002029407400700105 |
id |
doaj-42e83300f5104ff7b3a751deab78a134 |
---|---|
record_format |
Article |
spelling |
doaj-42e83300f5104ff7b3a751deab78a1342020-11-25T03:21:38ZengSAGE PublishingMeasurement + Control0020-29401974-01-01710.1177/002029407400700105Calibration of Gas-Metering ConstrictionsT. H. Redding0 Imperial College of Science & TechnologyTo extend the range of usefulness of a water calibrated metering constriction in the field of gas flow measurement, a method is described for determining the expansion coefficient (∈) which does not involve measurement of gas flow rate, while the precision of the method is such as to achieve accuracy tolerances of the order ±0· 30%. When used in conjunction with flow coefficients appropriate to incompressible flow, the flow coefficient appropriate to compressible flow is determined with an overall tolerance well within the limits ±0· 5% over a range of ∈ of 1 > ∈ > 0· 90.https://doi.org/10.1177/002029407400700105 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
T. H. Redding |
spellingShingle |
T. H. Redding Calibration of Gas-Metering Constrictions Measurement + Control |
author_facet |
T. H. Redding |
author_sort |
T. H. Redding |
title |
Calibration of Gas-Metering Constrictions |
title_short |
Calibration of Gas-Metering Constrictions |
title_full |
Calibration of Gas-Metering Constrictions |
title_fullStr |
Calibration of Gas-Metering Constrictions |
title_full_unstemmed |
Calibration of Gas-Metering Constrictions |
title_sort |
calibration of gas-metering constrictions |
publisher |
SAGE Publishing |
series |
Measurement + Control |
issn |
0020-2940 |
publishDate |
1974-01-01 |
description |
To extend the range of usefulness of a water calibrated metering constriction in the field of gas flow measurement, a method is described for determining the expansion coefficient (∈) which does not involve measurement of gas flow rate, while the precision of the method is such as to achieve accuracy tolerances of the order ±0· 30%. When used in conjunction with flow coefficients appropriate to incompressible flow, the flow coefficient appropriate to compressible flow is determined with an overall tolerance well within the limits ±0· 5% over a range of ∈ of 1 > ∈ > 0· 90. |
url |
https://doi.org/10.1177/002029407400700105 |
work_keys_str_mv |
AT thredding calibrationofgasmeteringconstrictions |
_version_ |
1724613633007157248 |