Calibration of Gas-Metering Constrictions

To extend the range of usefulness of a water calibrated metering constriction in the field of gas flow measurement, a method is described for determining the expansion coefficient (∈) which does not involve measurement of gas flow rate, while the precision of the method is such as to achieve accurac...

Full description

Bibliographic Details
Main Author: T. H. Redding
Format: Article
Language:English
Published: SAGE Publishing 1974-01-01
Series:Measurement + Control
Online Access:https://doi.org/10.1177/002029407400700105
Description
Summary:To extend the range of usefulness of a water calibrated metering constriction in the field of gas flow measurement, a method is described for determining the expansion coefficient (∈) which does not involve measurement of gas flow rate, while the precision of the method is such as to achieve accuracy tolerances of the order ±0· 30%. When used in conjunction with flow coefficients appropriate to incompressible flow, the flow coefficient appropriate to compressible flow is determined with an overall tolerance well within the limits ±0· 5% over a range of ∈ of 1 > ∈ > 0· 90.
ISSN:0020-2940