Control of the axial offset in a nuclear reactor at power maneuvering
High reliability and security of power unit are basic requirements when the power unit maneuvering mode operation. The reactor stability under disturbances both at steady load and maneuvering load embodies the guarantees of power unit safe and reliable operation. A quantitative measure of the reacto...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Odessa National Polytechnic University
2014-12-01
|
Series: | Trudy Odesskogo Politehničeskogo Universiteta |
Subjects: | |
Online Access: | http://pratsi.opu.ua/articles/show/1112 |
Summary: | High reliability and security of power unit are basic requirements when the power unit maneuvering mode operation. The reactor stability under disturbances both at steady load and maneuvering load embodies the guarantees of power unit safe and reliable operation. A quantitative measure of the reactor stability is assessed by the axial offset representing the technological characteristics of energy release uniformity, therefore the axial offset minimum deviation is WWER-1000 operation efficiency measure. The power unit capacity automated control systems’ influence on axial offset under maneuvering mode is investigated. Considered is the power unit compromise-combined control program, which maintains a constant axial offset value when power unit switching from one power level to another. |
---|---|
ISSN: | 2076-2429 2223-3814 |