Methods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control system
The method is based on data obtained from the so-called. hand-held measuring current at 10 kV voltage level and from reports of outages at reclosers that are installed in a part of network that is observed. At first, is calculates the electrical load of the main distribution power lines, and then si...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Electrical Engineering Institute Nikola Tesla
2013-01-01
|
Series: | Zbornik Radova: Elektrotehnički Institut "Nikola Tesla" |
Subjects: | |
Online Access: | http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2013/0350-85281323125V.pdf |
id |
doaj-428cc6c48cd743178d3ebfe119b83e36 |
---|---|
record_format |
Article |
spelling |
doaj-428cc6c48cd743178d3ebfe119b83e362020-11-24T22:32:52ZengElectrical Engineering Institute Nikola TeslaZbornik Radova: Elektrotehnički Institut "Nikola Tesla"0350-85282406-12122013-01-0120132312514010.5937/zeint23-46240350-85281323125VMethods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control systemVrcelj Nada0University of Belgrade, Electrical Engineering Institute “Nikola Tesla“, Belgrade, Belgrade, SerbiaThe method is based on data obtained from the so-called. hand-held measuring current at 10 kV voltage level and from reports of outages at reclosers that are installed in a part of network that is observed. At first, is calculates the electrical load of the main distribution power lines, and then simulates the corresponding power flow and calculates the undelivered electricity. The method was applied to parts of the network PD ED Belgrade that are not in the remote control system and is developed for the purpose of considering the effects of automation in the 10 kV PD ED Belgrade.http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2013/0350-85281323125V.pdfmethodsestimateundelivered electricityreclosersPD ED Belgrade |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Vrcelj Nada |
spellingShingle |
Vrcelj Nada Methods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control system Zbornik Radova: Elektrotehnički Institut "Nikola Tesla" methods estimate undelivered electricity reclosers PD ED Belgrade |
author_facet |
Vrcelj Nada |
author_sort |
Vrcelj Nada |
title |
Methods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control system |
title_short |
Methods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control system |
title_full |
Methods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control system |
title_fullStr |
Methods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control system |
title_full_unstemmed |
Methods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control system |
title_sort |
methods for calculation of undelivered electricity in medium voltage network that is not integrated into the remote control system |
publisher |
Electrical Engineering Institute Nikola Tesla |
series |
Zbornik Radova: Elektrotehnički Institut "Nikola Tesla" |
issn |
0350-8528 2406-1212 |
publishDate |
2013-01-01 |
description |
The method is based on data obtained from the so-called. hand-held measuring current at 10 kV voltage level and from reports of outages at reclosers that are installed in a part of network that is observed. At first, is calculates the electrical load of the main distribution power lines, and then simulates the corresponding power flow and calculates the undelivered electricity. The method was applied to parts of the network PD ED Belgrade that are not in the remote control system and is developed for the purpose of considering the effects of automation in the 10 kV PD ED Belgrade. |
topic |
methods estimate undelivered electricity reclosers PD ED Belgrade |
url |
http://scindeks-clanci.ceon.rs/data/pdf/0350-8528/2013/0350-85281323125V.pdf |
work_keys_str_mv |
AT vrceljnada methodsforcalculationofundeliveredelectricityinmediumvoltagenetworkthatisnotintegratedintotheremotecontrolsystem |
_version_ |
1725731942313230336 |