Analysis of the impact of pump system control on pressure gradients during emergency leaks in pipelines

The impact of a pump control system on the recorded pressure values along the pipeline during emergency leaks is discussed in the paper. A comparison was made for the designed experimental installation with a length of 1100 m and a diameter of DN 63 mm. The calculations were made using the Epanet 2...

Full description

Bibliographic Details
Main Authors: Sowiński Jarosław, Dziubiński Marek
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:E3S Web of Conferences
Online Access:https://doi.org/10.1051/e3sconf/20184400166
id doaj-427618ba4b984051bc2dbf16c830c85c
record_format Article
spelling doaj-427618ba4b984051bc2dbf16c830c85c2021-02-02T06:28:30ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01440016610.1051/e3sconf/20184400166e3sconf_eko-dok2018_00166Analysis of the impact of pump system control on pressure gradients during emergency leaks in pipelinesSowiński JarosławDziubiński MarekThe impact of a pump control system on the recorded pressure values along the pipeline during emergency leaks is discussed in the paper. A comparison was made for the designed experimental installation with a length of 1100 m and a diameter of DN 63 mm. The calculations were made using the Epanet 2 program. Results of the performed calculations prove that apart from a detailed description of hydraulic parameters of the pipeline on the size of emergency leaks from the pipeline, it is also important to properly describe the pump control system.https://doi.org/10.1051/e3sconf/20184400166
collection DOAJ
language English
format Article
sources DOAJ
author Sowiński Jarosław
Dziubiński Marek
spellingShingle Sowiński Jarosław
Dziubiński Marek
Analysis of the impact of pump system control on pressure gradients during emergency leaks in pipelines
E3S Web of Conferences
author_facet Sowiński Jarosław
Dziubiński Marek
author_sort Sowiński Jarosław
title Analysis of the impact of pump system control on pressure gradients during emergency leaks in pipelines
title_short Analysis of the impact of pump system control on pressure gradients during emergency leaks in pipelines
title_full Analysis of the impact of pump system control on pressure gradients during emergency leaks in pipelines
title_fullStr Analysis of the impact of pump system control on pressure gradients during emergency leaks in pipelines
title_full_unstemmed Analysis of the impact of pump system control on pressure gradients during emergency leaks in pipelines
title_sort analysis of the impact of pump system control on pressure gradients during emergency leaks in pipelines
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2018-01-01
description The impact of a pump control system on the recorded pressure values along the pipeline during emergency leaks is discussed in the paper. A comparison was made for the designed experimental installation with a length of 1100 m and a diameter of DN 63 mm. The calculations were made using the Epanet 2 program. Results of the performed calculations prove that apart from a detailed description of hydraulic parameters of the pipeline on the size of emergency leaks from the pipeline, it is also important to properly describe the pump control system.
url https://doi.org/10.1051/e3sconf/20184400166
work_keys_str_mv AT sowinskijarosław analysisoftheimpactofpumpsystemcontrolonpressuregradientsduringemergencyleaksinpipelines
AT dziubinskimarek analysisoftheimpactofpumpsystemcontrolonpressuregradientsduringemergencyleaksinpipelines
_version_ 1724301286095978496