A Case Study of an Ethylene Oxide Explosion in a Sterilization Facility

Ethylene oxide is widely used as a sterilizing agent for medical and food applications and products. However, due to its broad range of flammability (2.6 % to 100 %) in air, this gas presents a particularly serious explosion hazard, which is compounded by extremely stringent and ever increasing requ...

Full description

Bibliographic Details
Main Authors: A. Reza, E. Christiansen
Format: Article
Language:English
Published: AIDIC Servizi S.r.l. 2013-05-01
Series:Chemical Engineering Transactions
Online Access:https://www.cetjournal.it/index.php/cet/article/view/6857
id doaj-42665de90c574e8d80e2ed39b8e6a92e
record_format Article
spelling doaj-42665de90c574e8d80e2ed39b8e6a92e2021-02-22T21:01:18ZengAIDIC Servizi S.r.l.Chemical Engineering Transactions2283-92162013-05-013110.3303/CET1331078A Case Study of an Ethylene Oxide Explosion in a Sterilization FacilityA. RezaE. ChristiansenEthylene oxide is widely used as a sterilizing agent for medical and food applications and products. However, due to its broad range of flammability (2.6 % to 100 %) in air, this gas presents a particularly serious explosion hazard, which is compounded by extremely stringent and ever increasing requirements for pollution control equipment. Many emission control devices contain potential ignition sources, such as open flames, that could trigger an explosion. Engineering controls and safety interlocks are therefore critical to prevent explosions during abnormal operation and process upsets. This paper describes an investigation of a large explosion that caused extensive damage at a sterilization facility in the United States in August, 2004. The incident occurred as workers were attempting to troubleshoot one of their sterilization chambers and consequently bypassed safety interlocks while evacuating the gas. This allowed a flammable mixture to enter an ethylene oxide destruction unit (abator), which utilized an open flame to preheat waste gases before they passed through a catalytic oxidizer bed. The resulting deflagration propagated through the ductwork and back into the sterilization chamber, which exploded. The authors present the lessons learned from this incident through their direct involvement with the incident investigation as well as a review of previous, similar incidents investigated by the United States Environmental Protection Agency (EPA). The root cause and contributory factors for this explosion are discussed and recommendations provided on how similar incidents might be avoided in the future. One of the authors serves on the NFPA committee responsible for publishing the standard on safe storage, handling and use of ethylene oxide, and the paper concludes with an regulatory and industry perspective on alternative designs and equipment that could have prevented the explosion or vented/diverted the overpressure in order to lessen the damage to the workers and the facility.https://www.cetjournal.it/index.php/cet/article/view/6857
collection DOAJ
language English
format Article
sources DOAJ
author A. Reza
E. Christiansen
spellingShingle A. Reza
E. Christiansen
A Case Study of an Ethylene Oxide Explosion in a Sterilization Facility
Chemical Engineering Transactions
author_facet A. Reza
E. Christiansen
author_sort A. Reza
title A Case Study of an Ethylene Oxide Explosion in a Sterilization Facility
title_short A Case Study of an Ethylene Oxide Explosion in a Sterilization Facility
title_full A Case Study of an Ethylene Oxide Explosion in a Sterilization Facility
title_fullStr A Case Study of an Ethylene Oxide Explosion in a Sterilization Facility
title_full_unstemmed A Case Study of an Ethylene Oxide Explosion in a Sterilization Facility
title_sort case study of an ethylene oxide explosion in a sterilization facility
publisher AIDIC Servizi S.r.l.
series Chemical Engineering Transactions
issn 2283-9216
publishDate 2013-05-01
description Ethylene oxide is widely used as a sterilizing agent for medical and food applications and products. However, due to its broad range of flammability (2.6 % to 100 %) in air, this gas presents a particularly serious explosion hazard, which is compounded by extremely stringent and ever increasing requirements for pollution control equipment. Many emission control devices contain potential ignition sources, such as open flames, that could trigger an explosion. Engineering controls and safety interlocks are therefore critical to prevent explosions during abnormal operation and process upsets. This paper describes an investigation of a large explosion that caused extensive damage at a sterilization facility in the United States in August, 2004. The incident occurred as workers were attempting to troubleshoot one of their sterilization chambers and consequently bypassed safety interlocks while evacuating the gas. This allowed a flammable mixture to enter an ethylene oxide destruction unit (abator), which utilized an open flame to preheat waste gases before they passed through a catalytic oxidizer bed. The resulting deflagration propagated through the ductwork and back into the sterilization chamber, which exploded. The authors present the lessons learned from this incident through their direct involvement with the incident investigation as well as a review of previous, similar incidents investigated by the United States Environmental Protection Agency (EPA). The root cause and contributory factors for this explosion are discussed and recommendations provided on how similar incidents might be avoided in the future. One of the authors serves on the NFPA committee responsible for publishing the standard on safe storage, handling and use of ethylene oxide, and the paper concludes with an regulatory and industry perspective on alternative designs and equipment that could have prevented the explosion or vented/diverted the overpressure in order to lessen the damage to the workers and the facility.
url https://www.cetjournal.it/index.php/cet/article/view/6857
work_keys_str_mv AT areza acasestudyofanethyleneoxideexplosioninasterilizationfacility
AT echristiansen acasestudyofanethyleneoxideexplosioninasterilizationfacility
AT areza casestudyofanethyleneoxideexplosioninasterilizationfacility
AT echristiansen casestudyofanethyleneoxideexplosioninasterilizationfacility
_version_ 1724256247148969984