Mock-up Test of Time Lag in Floor Heating Systems with PCM
This research analyzes the time lag, which is a thermal storage performance parameter, when a phase change material is applied to the floor heating system of a mock-up laboratory. The following results are obtained. In terms of the time required for the floor surface temperature to reach 30 °C, the...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2019-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/37/e3sconf_clima2019_06061.pdf |
id |
doaj-42661b32a5984ee8a2c05c4115ca78c9 |
---|---|
record_format |
Article |
spelling |
doaj-42661b32a5984ee8a2c05c4115ca78c92021-03-02T09:36:12ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011110606110.1051/e3sconf/201911106061e3sconf_clima2019_06061Mock-up Test of Time Lag in Floor Heating Systems with PCMChoi Sung HoKim Tae WonPark Jin Chul0School of Architecture and Building Science, Chung-Ang UniversityThis research analyzes the time lag, which is a thermal storage performance parameter, when a phase change material is applied to the floor heating system of a mock-up laboratory. The following results are obtained. In terms of the time required for the floor surface temperature to reach 30 °C, the time lag of Room 2 (i.e., the room with the PCM-based floor system) was observed to be 15 min. Additionally, in terms of the time required for the floor surface temperature to decrease to 22 °C, Room 2 exhibited a time lag of 5 h 2 min. Therefore, the study concluded that longer time lags are observed with floor heating systems with PCM.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/37/e3sconf_clima2019_06061.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Choi Sung Ho Kim Tae Won Park Jin Chul |
spellingShingle |
Choi Sung Ho Kim Tae Won Park Jin Chul Mock-up Test of Time Lag in Floor Heating Systems with PCM E3S Web of Conferences |
author_facet |
Choi Sung Ho Kim Tae Won Park Jin Chul |
author_sort |
Choi Sung Ho |
title |
Mock-up Test of Time Lag in Floor Heating Systems with PCM |
title_short |
Mock-up Test of Time Lag in Floor Heating Systems with PCM |
title_full |
Mock-up Test of Time Lag in Floor Heating Systems with PCM |
title_fullStr |
Mock-up Test of Time Lag in Floor Heating Systems with PCM |
title_full_unstemmed |
Mock-up Test of Time Lag in Floor Heating Systems with PCM |
title_sort |
mock-up test of time lag in floor heating systems with pcm |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2019-01-01 |
description |
This research analyzes the time lag, which is a thermal storage performance parameter, when a phase change material is applied to the floor heating system of a mock-up laboratory. The following results are obtained. In terms of the time required for the floor surface temperature to reach 30 °C, the time lag of Room 2 (i.e., the room with the PCM-based floor system) was observed to be 15 min. Additionally, in terms of the time required for the floor surface temperature to decrease to 22 °C, Room 2 exhibited a time lag of 5 h 2 min. Therefore, the study concluded that longer time lags are observed with floor heating systems with PCM. |
url |
https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/37/e3sconf_clima2019_06061.pdf |
work_keys_str_mv |
AT choisungho mockuptestoftimelaginfloorheatingsystemswithpcm AT kimtaewon mockuptestoftimelaginfloorheatingsystemswithpcm AT parkjinchul mockuptestoftimelaginfloorheatingsystemswithpcm |
_version_ |
1724239023584575488 |