The Effects of Combining Drill Diameters Bypass, and Implant Bed under Preparation Protocols on Primary Stability of Dental Implant in Low-Density Bones (Experimental Study)
Aims: The aim of the current study is to compare the impact of using different drilling protocols on the dental implants primary stability inserted in the low-density bones. Materials and Methods: Out of twenty-two, ten oxen ribs were used in this in-vitro study. Using computed tomography (CT) scan,...
Main Authors: | , |
---|---|
Format: | Article |
Language: | Arabic |
Published: |
University of Mosul, College of Dentistry
2020-05-01
|
Series: | Al-Rafidain Dental Journal |
Subjects: | |
Online Access: | https://rden.mosuljournals.com/pdf_164656_1a7d0c7fbe13613207230b52c25d686c.html |
id |
doaj-421a411e7bca4b8d97a6850459445a4e |
---|---|
record_format |
Article |
spelling |
doaj-421a411e7bca4b8d97a6850459445a4e2020-11-25T02:33:58ZaraUniversity of Mosul, College of DentistryAl-Rafidain Dental Journal 1812-12171998-03452020-05-0120113414210.33899/rden.2020.126765.1023The Effects of Combining Drill Diameters Bypass, and Implant Bed under Preparation Protocols on Primary Stability of Dental Implant in Low-Density Bones (Experimental Study)Zaid Faris Y. Bashir Mohammad S. Sluaiman Aims: The aim of the current study is to compare the impact of using different drilling protocols on the dental implants primary stability inserted in the low-density bones. Materials and Methods: Out of twenty-two, ten oxen ribs were used in this in-vitro study. Using computed tomography (CT) scan, the most proximal three centimeters (cm) of the rib was confirmed to be a low-density bone comparable to human edentulous jaw bones. Forty dental implants were inserted, each rib received four dental implants using four different techniques that are arranged into four study groups:Group (I): includes a number of ten dental implants where the drilling burs and implants have the same size. Fit-size technique (F.G).Group (II): includes a number of ten dental implants where the diameter of the drilling burs is less than the implant diameter. Under-sized technique (U.G) Group (III): includes a number of ten dental implants where the simplified drilling protocol (Drill bypass) (D.G) was used for insertion.Group (IV): includes a number of ten dental implants where combined drilling protocols (C.G) (Undersized U.G+ Drill bypass D.G) were used for insertion. Results: Results revealed a statistically significant difference in the mean of insertion torque values (IT) between combined group (C.G) (65.000 N.cm) and fit-sized group (F.G) (45.0000 N.cm).Concerning Periotest M, a statistically significant difference was found in the mean of (PTV) between combined group (C.G) (-6.4500) and fit-sized group. A statistically highly significant correlation was found between insertion torque values (ITs) and Periotest M values (PTVs). Conclusion: Dental implant insertion in low-density bones using simplified drilling protocol (Drill bypass) (D.G) is better to be combined with undersized implant bed preparation (U.G) to enhance implant primary stability and with less time.Keywords: Kinesiology adhesive tape, Swelling, Pain, Dexamethasone, lower third molar teeth removal.https://rden.mosuljournals.com/pdf_164656_1a7d0c7fbe13613207230b52c25d686c.htmlprimary stability of dental implantdrill bypassunder preparation |
collection |
DOAJ |
language |
Arabic |
format |
Article |
sources |
DOAJ |
author |
Zaid Faris Y. Bashir Mohammad S. Sluaiman |
spellingShingle |
Zaid Faris Y. Bashir Mohammad S. Sluaiman The Effects of Combining Drill Diameters Bypass, and Implant Bed under Preparation Protocols on Primary Stability of Dental Implant in Low-Density Bones (Experimental Study) Al-Rafidain Dental Journal primary stability of dental implant drill bypass under preparation |
author_facet |
Zaid Faris Y. Bashir Mohammad S. Sluaiman |
author_sort |
Zaid Faris Y. Bashir |
title |
The Effects of Combining Drill Diameters Bypass, and Implant Bed under Preparation Protocols on Primary Stability of Dental Implant in Low-Density Bones (Experimental Study) |
title_short |
The Effects of Combining Drill Diameters Bypass, and Implant Bed under Preparation Protocols on Primary Stability of Dental Implant in Low-Density Bones (Experimental Study) |
title_full |
The Effects of Combining Drill Diameters Bypass, and Implant Bed under Preparation Protocols on Primary Stability of Dental Implant in Low-Density Bones (Experimental Study) |
title_fullStr |
The Effects of Combining Drill Diameters Bypass, and Implant Bed under Preparation Protocols on Primary Stability of Dental Implant in Low-Density Bones (Experimental Study) |
title_full_unstemmed |
The Effects of Combining Drill Diameters Bypass, and Implant Bed under Preparation Protocols on Primary Stability of Dental Implant in Low-Density Bones (Experimental Study) |
title_sort |
effects of combining drill diameters bypass, and implant bed under preparation protocols on primary stability of dental implant in low-density bones (experimental study) |
publisher |
University of Mosul, College of Dentistry |
series |
Al-Rafidain Dental Journal |
issn |
1812-1217 1998-0345 |
publishDate |
2020-05-01 |
description |
Aims: The aim of the current study is to compare the impact of using different drilling protocols on the dental implants primary stability inserted in the low-density bones. Materials and Methods: Out of twenty-two, ten oxen ribs were used in this in-vitro study. Using computed tomography (CT) scan, the most proximal three centimeters (cm) of the rib was confirmed to be a low-density bone comparable to human edentulous jaw bones. Forty dental implants were inserted, each rib received four dental implants using four different techniques that are arranged into four study groups:Group (I): includes a number of ten dental implants where the drilling burs and implants have the same size. Fit-size technique (F.G).Group (II): includes a number of ten dental implants where the diameter of the drilling burs is less than the implant diameter. Under-sized technique (U.G) Group (III): includes a number of ten dental implants where the simplified drilling protocol (Drill bypass) (D.G) was used for insertion.Group (IV): includes a number of ten dental implants where combined drilling protocols (C.G) (Undersized U.G+ Drill bypass D.G) were used for insertion. Results: Results revealed a statistically significant difference in the mean of insertion torque values (IT) between combined group (C.G) (65.000 N.cm) and fit-sized group (F.G) (45.0000 N.cm).Concerning Periotest M, a statistically significant difference was found in the mean of (PTV) between combined group (C.G) (-6.4500) and fit-sized group. A statistically highly significant correlation was found between insertion torque values (ITs) and Periotest M values (PTVs). Conclusion: Dental implant insertion in low-density bones using simplified drilling protocol (Drill bypass) (D.G) is better to be combined with undersized implant bed preparation (U.G) to enhance implant primary stability and with less time.Keywords: Kinesiology adhesive tape, Swelling, Pain, Dexamethasone, lower third molar teeth removal. |
topic |
primary stability of dental implant drill bypass under preparation |
url |
https://rden.mosuljournals.com/pdf_164656_1a7d0c7fbe13613207230b52c25d686c.html |
work_keys_str_mv |
AT zaidfarisybashir theeffectsofcombiningdrilldiametersbypassandimplantbedunderpreparationprotocolsonprimarystabilityofdentalimplantinlowdensitybonesexperimentalstudy AT mohammadssluaiman theeffectsofcombiningdrilldiametersbypassandimplantbedunderpreparationprotocolsonprimarystabilityofdentalimplantinlowdensitybonesexperimentalstudy AT zaidfarisybashir effectsofcombiningdrilldiametersbypassandimplantbedunderpreparationprotocolsonprimarystabilityofdentalimplantinlowdensitybonesexperimentalstudy AT mohammadssluaiman effectsofcombiningdrilldiametersbypassandimplantbedunderpreparationprotocolsonprimarystabilityofdentalimplantinlowdensitybonesexperimentalstudy |
_version_ |
1724811183065661440 |