Fault Modeling of IIDG Considering Inverter’s Detailed Characteristics

As more and more inverter interfaced distributed generators (IIDGs) such as PV are connected to the distribution network (DN), the existing relay protection system may malfunction due to the impact of the IIDGs. In order to evaluate that impact, the fault analysis of the DN with IIDGs is needed and...

Full description

Bibliographic Details
Main Authors: Xiaohan Shi, Hengxu Zhang, Chuanzi Wei, Zeyu Li, Shi Chen
Format: Article
Language:English
Published: IEEE 2020-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9207932/
id doaj-418a267c6979473ba397d0116c9b547b
record_format Article
spelling doaj-418a267c6979473ba397d0116c9b547b2021-03-30T04:01:54ZengIEEEIEEE Access2169-35362020-01-01818340118341010.1109/ACCESS.2020.30273239207932Fault Modeling of IIDG Considering Inverter’s Detailed CharacteristicsXiaohan Shi0https://orcid.org/0000-0003-3775-3076Hengxu Zhang1https://orcid.org/0000-0001-5315-0887Chuanzi Wei2Zeyu Li3Shi Chen4Key Laboratory of Power System Intelligent Dispatch and Control, Ministry of Education, Shandong University, Jinan, ChinaKey Laboratory of Power System Intelligent Dispatch and Control, Ministry of Education, Shandong University, Jinan, ChinaTai’an Power Supply Company, State Grid Shandong Electric Power Company, Tai’an, ChinaKey Laboratory of Power System Intelligent Dispatch and Control, Ministry of Education, Shandong University, Jinan, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaAs more and more inverter interfaced distributed generators (IIDGs) such as PV are connected to the distribution network (DN), the existing relay protection system may malfunction due to the impact of the IIDGs. In order to evaluate that impact, the fault analysis of the DN with IIDGs is needed and the fault modelling of IIDG is of great significant for the fault analysis and the protection system validation and improvement. This paper proposes a new fault modelling method of IIDG that could consider the detailed characteristics of the inverter in different situations including the limitation of the modulation. The symmetrical fault model of PQ controlled IIDG is deduced by the proposed method, based on which the symmetrical fault analysis of the DN with IIDGs is carried out. The proposed model depicts IIDG as a voltage-controlled current source or a voltage-controlled voltage source according to whether the modulation is limited, therefore covers the full characteristics of the inverter under different conditions, improving the modelling accuracy. The case study based on the modified IEEE 13 nodes system shows that the fault analysis results obtained from the proposed model are more consistent with electromagnetic transient simulation than that of the state-of-art fault model, verifying its effectiveness.https://ieeexplore.ieee.org/document/9207932/Inverter interfaced distributed generator (IIDG)stagtewise fault model of IIDGfault analysis of the distribution network with IIDGsmodulation limitationfault ride-through
collection DOAJ
language English
format Article
sources DOAJ
author Xiaohan Shi
Hengxu Zhang
Chuanzi Wei
Zeyu Li
Shi Chen
spellingShingle Xiaohan Shi
Hengxu Zhang
Chuanzi Wei
Zeyu Li
Shi Chen
Fault Modeling of IIDG Considering Inverter’s Detailed Characteristics
IEEE Access
Inverter interfaced distributed generator (IIDG)
stagtewise fault model of IIDG
fault analysis of the distribution network with IIDGs
modulation limitation
fault ride-through
author_facet Xiaohan Shi
Hengxu Zhang
Chuanzi Wei
Zeyu Li
Shi Chen
author_sort Xiaohan Shi
title Fault Modeling of IIDG Considering Inverter’s Detailed Characteristics
title_short Fault Modeling of IIDG Considering Inverter’s Detailed Characteristics
title_full Fault Modeling of IIDG Considering Inverter’s Detailed Characteristics
title_fullStr Fault Modeling of IIDG Considering Inverter’s Detailed Characteristics
title_full_unstemmed Fault Modeling of IIDG Considering Inverter’s Detailed Characteristics
title_sort fault modeling of iidg considering inverter’s detailed characteristics
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2020-01-01
description As more and more inverter interfaced distributed generators (IIDGs) such as PV are connected to the distribution network (DN), the existing relay protection system may malfunction due to the impact of the IIDGs. In order to evaluate that impact, the fault analysis of the DN with IIDGs is needed and the fault modelling of IIDG is of great significant for the fault analysis and the protection system validation and improvement. This paper proposes a new fault modelling method of IIDG that could consider the detailed characteristics of the inverter in different situations including the limitation of the modulation. The symmetrical fault model of PQ controlled IIDG is deduced by the proposed method, based on which the symmetrical fault analysis of the DN with IIDGs is carried out. The proposed model depicts IIDG as a voltage-controlled current source or a voltage-controlled voltage source according to whether the modulation is limited, therefore covers the full characteristics of the inverter under different conditions, improving the modelling accuracy. The case study based on the modified IEEE 13 nodes system shows that the fault analysis results obtained from the proposed model are more consistent with electromagnetic transient simulation than that of the state-of-art fault model, verifying its effectiveness.
topic Inverter interfaced distributed generator (IIDG)
stagtewise fault model of IIDG
fault analysis of the distribution network with IIDGs
modulation limitation
fault ride-through
url https://ieeexplore.ieee.org/document/9207932/
work_keys_str_mv AT xiaohanshi faultmodelingofiidgconsideringinverterx2019sdetailedcharacteristics
AT hengxuzhang faultmodelingofiidgconsideringinverterx2019sdetailedcharacteristics
AT chuanziwei faultmodelingofiidgconsideringinverterx2019sdetailedcharacteristics
AT zeyuli faultmodelingofiidgconsideringinverterx2019sdetailedcharacteristics
AT shichen faultmodelingofiidgconsideringinverterx2019sdetailedcharacteristics
_version_ 1724182398002790400