ELABORATION OF HIGH-VOLTAGE PULSE INSTALLATIONS AND PROVIDING THEIR OPERATION PROTECTIVE MEASURES

The article presents design engineering methods for the high-voltage pulse installations of technological purpose for disinfection of drinking water, sewage, and edible liquids by high field micro- and nanosecond pulsing exposure. Designing potentialities are considered of the principal elements of...

Full description

Bibliographic Details
Main Authors: А. М. Hashimov, E. J. Gurbanov
Format: Article
Language:Russian
Published: Belarusian National Technical University 2016-03-01
Series:Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/996
id doaj-4143d2bb2c5f4c70bcea9ecd533c9428
record_format Article
spelling doaj-4143d2bb2c5f4c70bcea9ecd533c94282021-07-29T08:45:39ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412016-03-015929510510.21122/1029-7448-2016-59-2-129-133972ELABORATION OF HIGH-VOLTAGE PULSE INSTALLATIONS AND PROVIDING THEIR OPERATION PROTECTIVE MEASURESА. М. Hashimov0E. J. Gurbanov1Physics Institute of Azerbaijan National Academy of SciencesAzersu OJSC, BakuThe article presents design engineering methods for the high-voltage pulse installations of technological purpose for disinfection of drinking water, sewage, and edible liquids by high field micro- and nanosecond pulsing exposure. Designing potentialities are considered of the principal elements of the high-voltage part and the discharge circuit of the installations towards assuring the best efficient on-load utilization of the source energy and safe operation of the high-voltage equipment. The study shows that for disinfection of drinking water and sewage it is expedient to apply microsecond pulse actions causing the electrohydraulic effect in aqueous media with associated complex of physical processes (ultraviolet emission, generation of ozone and atomic oxygen, mechanical compression waves, etc.) having detrimental effect on life activity of the microorganisms. In case of disinfecting edible liquids it is recommended to use the nanosecond pulses capable of straight permeating the biological cell nucleus, inactivating it. Meanwhile, the nutritive and biological values of the foodstuffs are saved and their organoleptic properties are improved. It is noted that in elaboration process of high-frequency pulse installations special consideration should be given to issues of the operating personnel safety discipline and securing conditions for the entire installation uninterrupted performance. With this objective in view the necessary requirements should be fulfilled on shielding the high- and low-voltage installation parts against high-frequency electromagnetic emissions registered by special differential sensors. Simultaneously, the abatement measures should be applied on the high-voltage equipment operational noise level. The authors offer a technique for noise abatement to admissible levels (lower than 80 dB A) by means of coating the inside surface with shielded enclosure of densely-packed abutting sheets of porous electro-acoustic insulating material.https://energy.bntu.by/jour/article/view/996high-voltage pulse installation, pulsed discharge, front of pulse, pulse duration, generator of pulsed tensions, loading, electromagnetic emission, micro and nanosecond pulse, disinfecting, shielding, noise
collection DOAJ
language Russian
format Article
sources DOAJ
author А. М. Hashimov
E. J. Gurbanov
spellingShingle А. М. Hashimov
E. J. Gurbanov
ELABORATION OF HIGH-VOLTAGE PULSE INSTALLATIONS AND PROVIDING THEIR OPERATION PROTECTIVE MEASURES
Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
high-voltage pulse installation, pulsed discharge, front of pulse, pulse duration, generator of pulsed tensions, loading, electromagnetic emission, micro and nanosecond pulse, disinfecting, shielding, noise
author_facet А. М. Hashimov
E. J. Gurbanov
author_sort А. М. Hashimov
title ELABORATION OF HIGH-VOLTAGE PULSE INSTALLATIONS AND PROVIDING THEIR OPERATION PROTECTIVE MEASURES
title_short ELABORATION OF HIGH-VOLTAGE PULSE INSTALLATIONS AND PROVIDING THEIR OPERATION PROTECTIVE MEASURES
title_full ELABORATION OF HIGH-VOLTAGE PULSE INSTALLATIONS AND PROVIDING THEIR OPERATION PROTECTIVE MEASURES
title_fullStr ELABORATION OF HIGH-VOLTAGE PULSE INSTALLATIONS AND PROVIDING THEIR OPERATION PROTECTIVE MEASURES
title_full_unstemmed ELABORATION OF HIGH-VOLTAGE PULSE INSTALLATIONS AND PROVIDING THEIR OPERATION PROTECTIVE MEASURES
title_sort elaboration of high-voltage pulse installations and providing their operation protective measures
publisher Belarusian National Technical University
series Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
issn 1029-7448
2414-0341
publishDate 2016-03-01
description The article presents design engineering methods for the high-voltage pulse installations of technological purpose for disinfection of drinking water, sewage, and edible liquids by high field micro- and nanosecond pulsing exposure. Designing potentialities are considered of the principal elements of the high-voltage part and the discharge circuit of the installations towards assuring the best efficient on-load utilization of the source energy and safe operation of the high-voltage equipment. The study shows that for disinfection of drinking water and sewage it is expedient to apply microsecond pulse actions causing the electrohydraulic effect in aqueous media with associated complex of physical processes (ultraviolet emission, generation of ozone and atomic oxygen, mechanical compression waves, etc.) having detrimental effect on life activity of the microorganisms. In case of disinfecting edible liquids it is recommended to use the nanosecond pulses capable of straight permeating the biological cell nucleus, inactivating it. Meanwhile, the nutritive and biological values of the foodstuffs are saved and their organoleptic properties are improved. It is noted that in elaboration process of high-frequency pulse installations special consideration should be given to issues of the operating personnel safety discipline and securing conditions for the entire installation uninterrupted performance. With this objective in view the necessary requirements should be fulfilled on shielding the high- and low-voltage installation parts against high-frequency electromagnetic emissions registered by special differential sensors. Simultaneously, the abatement measures should be applied on the high-voltage equipment operational noise level. The authors offer a technique for noise abatement to admissible levels (lower than 80 dB A) by means of coating the inside surface with shielded enclosure of densely-packed abutting sheets of porous electro-acoustic insulating material.
topic high-voltage pulse installation, pulsed discharge, front of pulse, pulse duration, generator of pulsed tensions, loading, electromagnetic emission, micro and nanosecond pulse, disinfecting, shielding, noise
url https://energy.bntu.by/jour/article/view/996
work_keys_str_mv AT amhashimov elaborationofhighvoltagepulseinstallationsandprovidingtheiroperationprotectivemeasures
AT ejgurbanov elaborationofhighvoltagepulseinstallationsandprovidingtheiroperationprotectivemeasures
_version_ 1721251771600338944