CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor
An innovative integrated passive safety system for a research reactor is proposed in this study to improve the safety of the research reactor. This integrated system has three functions in the facility as a decay tank, siphon breaker, and long-term cooling tank. This paper also deals with the proces...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2017-01-01
|
Series: | Science and Technology of Nuclear Installations |
Online Access: | http://dx.doi.org/10.1155/2017/3106278 |
id |
doaj-410b4df3edcb44beb0e23d99963fe477 |
---|---|
record_format |
Article |
spelling |
doaj-410b4df3edcb44beb0e23d99963fe4772020-11-25T00:29:55ZengHindawi LimitedScience and Technology of Nuclear Installations1687-60751687-60832017-01-01201710.1155/2017/31062783106278CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research ReactorKwon-Yeong Lee0Hyun-Gi Yoon1Dong Kyou Park2Handong Global University, 558 Handong-ro, Buk-gu, Pohang, Gyeongbuk 37554, Republic of KoreaKorea Atomic Energy Research Institute, 111 Daedeok-daero, Yuseong-gu, Daejeon 34057, Republic of KoreaKorea University of Technology and Education, 1600 Chungjeol-ro, Byeongcheon-myeon, Dongnam-gu, Cheonan City, Chungnam 31253, Republic of KoreaAn innovative integrated passive safety system for a research reactor is proposed in this study to improve the safety of the research reactor. This integrated system has three functions in the facility as a decay tank, siphon breaker, and long-term cooling tank. This paper also deals with the process of designing and optimizing the decay tank and the siphon breaker of the integrated passive safety system. At first, the decay tank was designed and improved step by step, while considering the computational fluid dynamics analysis results. Consequently, we could satisfy the design requirements of the decay tank. In addition, the performance of a new type of siphon breaker that was installed in the final decay tank model was tested. We designed an 18-inch diameter siphon breaker at the top of the decay tank’s third section, and we could observe the breaking of the siphon that prevented the occurrence of a severe accident in the research reactor. By locating the siphon breaker at the third section of the decay tank, we could also use the coolant of the front three sections for long-term cooling of the research reactor.http://dx.doi.org/10.1155/2017/3106278 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Kwon-Yeong Lee Hyun-Gi Yoon Dong Kyou Park |
spellingShingle |
Kwon-Yeong Lee Hyun-Gi Yoon Dong Kyou Park CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor Science and Technology of Nuclear Installations |
author_facet |
Kwon-Yeong Lee Hyun-Gi Yoon Dong Kyou Park |
author_sort |
Kwon-Yeong Lee |
title |
CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor |
title_short |
CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor |
title_full |
CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor |
title_fullStr |
CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor |
title_full_unstemmed |
CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor |
title_sort |
cfd analysis of a decay tank and a siphon breaker for an innovative integrated passive safety system for a research reactor |
publisher |
Hindawi Limited |
series |
Science and Technology of Nuclear Installations |
issn |
1687-6075 1687-6083 |
publishDate |
2017-01-01 |
description |
An innovative integrated passive safety system for a research reactor is proposed in this study to improve the safety of the research reactor. This integrated system has three functions in the facility as a decay tank, siphon breaker, and long-term cooling tank. This paper also deals with the process of designing and optimizing the decay tank and the siphon breaker of the integrated passive safety system. At first, the decay tank was designed and improved step by step, while considering the computational fluid dynamics analysis results. Consequently, we could satisfy the design requirements of the decay tank. In addition, the performance of a new type of siphon breaker that was installed in the final decay tank model was tested. We designed an 18-inch diameter siphon breaker at the top of the decay tank’s third section, and we could observe the breaking of the siphon that prevented the occurrence of a severe accident in the research reactor. By locating the siphon breaker at the third section of the decay tank, we could also use the coolant of the front three sections for long-term cooling of the research reactor. |
url |
http://dx.doi.org/10.1155/2017/3106278 |
work_keys_str_mv |
AT kwonyeonglee cfdanalysisofadecaytankandasiphonbreakerforaninnovativeintegratedpassivesafetysystemforaresearchreactor AT hyungiyoon cfdanalysisofadecaytankandasiphonbreakerforaninnovativeintegratedpassivesafetysystemforaresearchreactor AT dongkyoupark cfdanalysisofadecaytankandasiphonbreakerforaninnovativeintegratedpassivesafetysystemforaresearchreactor |
_version_ |
1725328997108154368 |