A systematic parameter tuning of PI current controller for LCL-type active rectifiers under unbalanced grid voltage conditions

Active rectifiers are widely employed in three-phase electric drive or renewable energy resource systems because of the bidirectional power flow and the power factor correction. This paper proposes a systematic method to determine the parameters for the PI current controllers in active rectifier sys...

Full description

Bibliographic Details
Main Authors: Phuong Nguyen, Phuong Vu, Nam Hoang, Ngoc Nguyen, Quan Nguyen, Hung Do
Format: Article
Language:English
Published: ESRGroups 2019-03-01
Series:Journal of Electrical Systems
Subjects:
Online Access:https://journal.esrgroups.org/jes/papers/15_1_13.pdf
id doaj-40eecf3a1d714b0c9f59b8ae3ac5e690
record_format Article
spelling doaj-40eecf3a1d714b0c9f59b8ae3ac5e6902020-11-25T02:40:44ZengESRGroupsJournal of Electrical Systems1112-52091112-52092019-03-01151159168A systematic parameter tuning of PI current controller for LCL-type active rectifiers under unbalanced grid voltage conditions Phuong Nguyen0Phuong Vu1Nam Hoang2Ngoc Nguyen3Quan Nguyen4Hung Do5School of Electrical Engineering, Hanoi University of Science and Technology, Hanoi, VietnamSchool of Electrical Engineering, Hanoi University of Science and Technology, Hanoi, VietnamSchool of Electrical Engineering, Hanoi University of Science and Technology, Hanoi, VietnamSchool of Electrical Engineering, Hanoi University of Science and Technology, Hanoi, VietnamDepartment of Electrical and Computer Engineering, University of Texas at Austin, Texas, USAHanoi University of IndustryActive rectifiers are widely employed in three-phase electric drive or renewable energy resource systems because of the bidirectional power flow and the power factor correction. This paper proposes a systematic method to determine the parameters for the PI current controllers in active rectifier systems using LCL filter under unbalanced grid faults. The parameters of PI regulators are designed in frequency domain and taking into account the full model of the LCL filter as well as the time delay in control system, which improves the system stability and reliability. The simulation results in MATLAB and hardware-in-the-loop experimental simulation using the HIL 402 device of Typhoon validate the robust and capability of active rectifier in stabilizing the system under different non-ideal conditions of grid voltage.https://journal.esrgroups.org/jes/papers/15_1_13.pdfactive filterscurrent controllerslcl filtersunbalanced grid voltage.
collection DOAJ
language English
format Article
sources DOAJ
author Phuong Nguyen
Phuong Vu
Nam Hoang
Ngoc Nguyen
Quan Nguyen
Hung Do
spellingShingle Phuong Nguyen
Phuong Vu
Nam Hoang
Ngoc Nguyen
Quan Nguyen
Hung Do
A systematic parameter tuning of PI current controller for LCL-type active rectifiers under unbalanced grid voltage conditions
Journal of Electrical Systems
active filters
current controllers
lcl filters
unbalanced grid voltage.
author_facet Phuong Nguyen
Phuong Vu
Nam Hoang
Ngoc Nguyen
Quan Nguyen
Hung Do
author_sort Phuong Nguyen
title A systematic parameter tuning of PI current controller for LCL-type active rectifiers under unbalanced grid voltage conditions
title_short A systematic parameter tuning of PI current controller for LCL-type active rectifiers under unbalanced grid voltage conditions
title_full A systematic parameter tuning of PI current controller for LCL-type active rectifiers under unbalanced grid voltage conditions
title_fullStr A systematic parameter tuning of PI current controller for LCL-type active rectifiers under unbalanced grid voltage conditions
title_full_unstemmed A systematic parameter tuning of PI current controller for LCL-type active rectifiers under unbalanced grid voltage conditions
title_sort systematic parameter tuning of pi current controller for lcl-type active rectifiers under unbalanced grid voltage conditions
publisher ESRGroups
series Journal of Electrical Systems
issn 1112-5209
1112-5209
publishDate 2019-03-01
description Active rectifiers are widely employed in three-phase electric drive or renewable energy resource systems because of the bidirectional power flow and the power factor correction. This paper proposes a systematic method to determine the parameters for the PI current controllers in active rectifier systems using LCL filter under unbalanced grid faults. The parameters of PI regulators are designed in frequency domain and taking into account the full model of the LCL filter as well as the time delay in control system, which improves the system stability and reliability. The simulation results in MATLAB and hardware-in-the-loop experimental simulation using the HIL 402 device of Typhoon validate the robust and capability of active rectifier in stabilizing the system under different non-ideal conditions of grid voltage.
topic active filters
current controllers
lcl filters
unbalanced grid voltage.
url https://journal.esrgroups.org/jes/papers/15_1_13.pdf
work_keys_str_mv AT phuongnguyen asystematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT phuongvu asystematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT namhoang asystematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT ngocnguyen asystematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT quannguyen asystematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT hungdo asystematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT phuongnguyen systematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT phuongvu systematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT namhoang systematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT ngocnguyen systematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT quannguyen systematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
AT hungdo systematicparametertuningofpicurrentcontrollerforlcltypeactiverectifiersunderunbalancedgridvoltageconditions
_version_ 1724780081758339072