Simple fire model for comparative studies of critical conditions during combustion of chosen polymer materials
The time taken to evacuate space inside a building (required time for evacuation) must be shorter than the time for the environment in that space to become life threatening (available safe egress time ‐ ASET). That time is the time, when certain tenability limits of smoke filling, toxicity and ther...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Vilnius Gediminas Technical University
2009-09-01
|
Series: | Journal of Civil Engineering and Management |
Subjects: | |
Online Access: | https://www.bme.vgtu.lt/index.php/JCEM/article/view/6422 |
id |
doaj-40e97c5d30a9473f9ad7567e9697e13b |
---|---|
record_format |
Article |
spelling |
doaj-40e97c5d30a9473f9ad7567e9697e13b2021-07-02T03:51:52ZengVilnius Gediminas Technical UniversityJournal of Civil Engineering and Management1392-37301822-36052009-09-0115310.3846/1392-3730.2009.15.247-257Simple fire model for comparative studies of critical conditions during combustion of chosen polymer materialsMarek Konecki0Marzena Półka1Combustion and Fire Theory Division, The Main School of Fire Service, Słowackiego 52/54 Street, 01-629 Warsaw, PolandCombustion and Fire Theory Division, The Main School of Fire Service, Słowackiego 52/54 Street, 01-629 Warsaw, Poland The time taken to evacuate space inside a building (required time for evacuation) must be shorter than the time for the environment in that space to become life threatening (available safe egress time ‐ ASET). That time is the time, when certain tenability limits of smoke filling, toxicity and thermal influence of the building environment are exceeded. As a consequence of lost visibility in smoke, people loose their orientation, and consequently evacuation is slowed down or becomes impossible. In such conditions inhaling of an excessive volume of toxins may lead to loss of consciousness or death. In the paper are discussed the influences of visibility through a smoke layer (or smoke obscuration) and concentration of toxic products of combustion on ASET, in well ventilated fires. Apart from the visibility range, also CO and CO2 concentrations have been chosen for the analysis. The given simple formulas show the dependency of rate of combustion and yields of smoke and toxic species on visibility reduction rate and increasing of concentration of toxic products evolved during combustion of selected materials. Epoxy materials were used for the analysis: pure Epoxy material 561 and epoxy with the following admixtures: MoO3, Roflam P and Melamine, as well as 2 types of polyurethane form. Santrauka Laikas, reikalingas žmonėms evakuotis iš pastato (evakuacijos laikas), turi būti trumpesnis už laiką, per kurį konkreti pastato erdvė tampa pavojinga gyvybei (leistinas saugios evakuacijos laikas – angl. ASET). Šis laikas apibrėžia priimtinų dūmų plitimo, toksiškumo ir šiluminio poveikio pastato erdvei ribų viršijimą. Dėl dūmų žmonės praranda orientaciją, todėl evakuacija užsitęsia arba tampa neįmanoma. Dėl tokiomis aplinkos sąlygomis įkvepiamo didelio toksinų kiekio galima prarasti sąmonę ar net mirti. Straipsnyje apžvelgiama matomumo per dūmų sluoksnį ir toksiškų produktų koncentracijos įtaka evakuacijos laikui (ASET), kai degančioje patalpoje gaisro metu užtikrinama gera oro ventiliacija. Greta matomumo buvo tiriama CO ir CO2 koncentracijos įtaka evakuacijos laikui. Pateiktos formulės rodo degimo intensyvumo ir dūmų bei toksiškų priedų išsiskyrimo įtaką matomumo mažėjimui ir toksinių produktų koncentracijos didėjimui įvertinant konkrečios medžiagos degimą. Tyrimams naudotos šios medžiagos: epoksidinė medžiaga 561 be priemaišų, epoksidinė medžiaga su MoO3 , Roflam P ir Melamine priedais, dvi poliuretano detalės. First Published Online: 14 Oct 2010 Reikšminiai žodžiai: gaisras, toksiškieji produktai, dūmai, matomumas, evakuacija. https://www.bme.vgtu.lt/index.php/JCEM/article/view/6422firetoxic productssmokevisibilityevacuation |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Marek Konecki Marzena Półka |
spellingShingle |
Marek Konecki Marzena Półka Simple fire model for comparative studies of critical conditions during combustion of chosen polymer materials Journal of Civil Engineering and Management fire toxic products smoke visibility evacuation |
author_facet |
Marek Konecki Marzena Półka |
author_sort |
Marek Konecki |
title |
Simple fire model for comparative studies of critical conditions during combustion of chosen polymer materials |
title_short |
Simple fire model for comparative studies of critical conditions during combustion of chosen polymer materials |
title_full |
Simple fire model for comparative studies of critical conditions during combustion of chosen polymer materials |
title_fullStr |
Simple fire model for comparative studies of critical conditions during combustion of chosen polymer materials |
title_full_unstemmed |
Simple fire model for comparative studies of critical conditions during combustion of chosen polymer materials |
title_sort |
simple fire model for comparative studies of critical conditions during combustion of chosen polymer materials |
publisher |
Vilnius Gediminas Technical University |
series |
Journal of Civil Engineering and Management |
issn |
1392-3730 1822-3605 |
publishDate |
2009-09-01 |
description |
The time taken to evacuate space inside a building (required time for evacuation) must be shorter than the time for the environment in that space to become life threatening (available safe egress time ‐ ASET). That time is the time, when certain tenability limits of smoke filling, toxicity and thermal influence of the building environment are exceeded. As a consequence of lost visibility in smoke, people loose their orientation, and consequently evacuation is slowed down or becomes impossible. In such conditions inhaling of an excessive volume of toxins may lead to loss of consciousness or death. In the paper are discussed the influences of visibility through a smoke layer (or smoke obscuration) and concentration of toxic products of combustion on ASET, in well ventilated fires. Apart from the visibility range, also CO and CO2 concentrations have been chosen for the analysis. The given simple formulas show the dependency of rate of combustion and yields of smoke and toxic species on visibility reduction rate and increasing of concentration of toxic products evolved during combustion of selected materials. Epoxy materials were used for the analysis: pure Epoxy material 561 and epoxy with the following admixtures: MoO3, Roflam P and Melamine, as well as 2 types of polyurethane form.
Santrauka
Laikas, reikalingas žmonėms evakuotis iš pastato (evakuacijos laikas), turi būti trumpesnis už laiką, per kurį konkreti pastato erdvė tampa pavojinga gyvybei (leistinas saugios evakuacijos laikas – angl. ASET). Šis laikas apibrėžia priimtinų dūmų plitimo, toksiškumo ir šiluminio poveikio pastato erdvei ribų viršijimą. Dėl dūmų žmonės praranda orientaciją, todėl evakuacija užsitęsia arba tampa neįmanoma. Dėl tokiomis aplinkos sąlygomis įkvepiamo didelio toksinų kiekio galima prarasti sąmonę ar net mirti. Straipsnyje apžvelgiama matomumo per dūmų sluoksnį ir toksiškų produktų koncentracijos įtaka evakuacijos laikui (ASET), kai degančioje patalpoje gaisro metu užtikrinama gera oro ventiliacija. Greta matomumo buvo tiriama CO ir CO2 koncentracijos įtaka evakuacijos laikui. Pateiktos formulės rodo degimo intensyvumo ir dūmų bei toksiškų priedų išsiskyrimo įtaką matomumo mažėjimui ir toksinių produktų koncentracijos didėjimui įvertinant konkrečios medžiagos degimą. Tyrimams naudotos šios medžiagos: epoksidinė medžiaga 561 be priemaišų, epoksidinė medžiaga su MoO3 , Roflam P ir Melamine priedais, dvi poliuretano detalės.
First Published Online: 14 Oct 2010
Reikšminiai žodžiai: gaisras, toksiškieji produktai, dūmai, matomumas, evakuacija.
|
topic |
fire toxic products smoke visibility evacuation |
url |
https://www.bme.vgtu.lt/index.php/JCEM/article/view/6422 |
work_keys_str_mv |
AT marekkonecki simplefiremodelforcomparativestudiesofcriticalconditionsduringcombustionofchosenpolymermaterials AT marzenapołka simplefiremodelforcomparativestudiesofcriticalconditionsduringcombustionofchosenpolymermaterials |
_version_ |
1721340996451565568 |