Usefulness of Rigid Bronchoscopic Intervention Using Argon Plasma Coagulation for Central Airway Tumors
ObjectivesArgon plasma coagulation (APC) is a noncontact form of electrocautery that utilizes ionized argon as the electrical current. A rigid bronchoscopic use of APC for the management of central airway obstruction could be safe and rapidly effective. This study evaluated the usefulness of rigid b...
Main Authors: | , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Korean Society of Otorhinolaryngology-Head and Neck Surgery
2015-12-01
|
Series: | Clinical and Experimental Otorhinolaryngology |
Subjects: | |
Online Access: | http://www.e-ceo.org/upload/pdf/ceo-8-396.pdf |
id |
doaj-409eac4d8bdb4f3b81465daccc7eb22c |
---|---|
record_format |
Article |
spelling |
doaj-409eac4d8bdb4f3b81465daccc7eb22c2020-11-24T21:58:16ZengKorean Society of Otorhinolaryngology-Head and Neck SurgeryClinical and Experimental Otorhinolaryngology1976-87102005-07202015-12-018439640110.3342/ceo.2015.8.4.396403Usefulness of Rigid Bronchoscopic Intervention Using Argon Plasma Coagulation for Central Airway TumorsBo-Ram Lee0In-Jae Oh1Ho-Sung Lee2Hee-Jung Ban3Kyu-Sik Kim4Yu-Il Kim5Sung-Chul Lim6Young-Chul Kim7Yong-Wook Park8Yong-Soo Kwon9Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Korea.ObjectivesArgon plasma coagulation (APC) is a noncontact form of electrocautery that utilizes ionized argon as the electrical current. A rigid bronchoscopic use of APC for the management of central airway obstruction could be safe and rapidly effective. This study evaluated the usefulness of rigid bronchoscopy with APC for the management of central airway obstructions due to benign or malignant tumors.MethodsTwenty patients with obstructing central airway tumors were retrospectively reviewed from February 2008 to February 2013 at Chonnam National University Hospital. All patients received rigid bronchoscopic tumor removal under general anesthesia. APC was applied before and after tumor removal.ResultsThe median age of patients was 59 years (interquartile range [IQR], 51 to 67 years) and 70% were female. The causes of airway obstruction included malignancy (n=8) and benign tumor (n=12). Airway tumors comprised intraluminal lesions (n=11, 55%) and mixed intraluminal/extraluminal lesions (n=9, 45%). The median tumor size was 15 mm (IQR, 10 to 18 mm). The median degree of airway obstruction was significantly reduced after intervention (90% [IQR, 88% to 96%] vs. 10% [IQR, 0% to 20%], P<0.001). The median American Thoracic Society dyspnea grade (3 [IQR, 1 to 4] vs. 1 [IQR, 0 to 1], P<0.001) and forced expiratory volume in one second (1.03 L [IQR, 0.52 to 1.36 L] vs. 1.98 L [IQR, 1.57 to 2.64 L], P=0.004) were significantly improved after intervention. There were no procedure-related acute complications and deaths.ConclusionRigid bronchoscopy with APC is an effective and safe procedure to alleviate central airway obstruction caused by tumors.http://www.e-ceo.org/upload/pdf/ceo-8-396.pdfArgon Plasma CoagulationBronchoscopyAirway Obstruction |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Bo-Ram Lee In-Jae Oh Ho-Sung Lee Hee-Jung Ban Kyu-Sik Kim Yu-Il Kim Sung-Chul Lim Young-Chul Kim Yong-Wook Park Yong-Soo Kwon |
spellingShingle |
Bo-Ram Lee In-Jae Oh Ho-Sung Lee Hee-Jung Ban Kyu-Sik Kim Yu-Il Kim Sung-Chul Lim Young-Chul Kim Yong-Wook Park Yong-Soo Kwon Usefulness of Rigid Bronchoscopic Intervention Using Argon Plasma Coagulation for Central Airway Tumors Clinical and Experimental Otorhinolaryngology Argon Plasma Coagulation Bronchoscopy Airway Obstruction |
author_facet |
Bo-Ram Lee In-Jae Oh Ho-Sung Lee Hee-Jung Ban Kyu-Sik Kim Yu-Il Kim Sung-Chul Lim Young-Chul Kim Yong-Wook Park Yong-Soo Kwon |
author_sort |
Bo-Ram Lee |
title |
Usefulness of Rigid Bronchoscopic Intervention Using Argon Plasma Coagulation for Central Airway Tumors |
title_short |
Usefulness of Rigid Bronchoscopic Intervention Using Argon Plasma Coagulation for Central Airway Tumors |
title_full |
Usefulness of Rigid Bronchoscopic Intervention Using Argon Plasma Coagulation for Central Airway Tumors |
title_fullStr |
Usefulness of Rigid Bronchoscopic Intervention Using Argon Plasma Coagulation for Central Airway Tumors |
title_full_unstemmed |
Usefulness of Rigid Bronchoscopic Intervention Using Argon Plasma Coagulation for Central Airway Tumors |
title_sort |
usefulness of rigid bronchoscopic intervention using argon plasma coagulation for central airway tumors |
publisher |
Korean Society of Otorhinolaryngology-Head and Neck Surgery |
series |
Clinical and Experimental Otorhinolaryngology |
issn |
1976-8710 2005-0720 |
publishDate |
2015-12-01 |
description |
ObjectivesArgon plasma coagulation (APC) is a noncontact form of electrocautery that utilizes ionized argon as the electrical current. A rigid bronchoscopic use of APC for the management of central airway obstruction could be safe and rapidly effective. This study evaluated the usefulness of rigid bronchoscopy with APC for the management of central airway obstructions due to benign or malignant tumors.MethodsTwenty patients with obstructing central airway tumors were retrospectively reviewed from February 2008 to February 2013 at Chonnam National University Hospital. All patients received rigid bronchoscopic tumor removal under general anesthesia. APC was applied before and after tumor removal.ResultsThe median age of patients was 59 years (interquartile range [IQR], 51 to 67 years) and 70% were female. The causes of airway obstruction included malignancy (n=8) and benign tumor (n=12). Airway tumors comprised intraluminal lesions (n=11, 55%) and mixed intraluminal/extraluminal lesions (n=9, 45%). The median tumor size was 15 mm (IQR, 10 to 18 mm). The median degree of airway obstruction was significantly reduced after intervention (90% [IQR, 88% to 96%] vs. 10% [IQR, 0% to 20%], P<0.001). The median American Thoracic Society dyspnea grade (3 [IQR, 1 to 4] vs. 1 [IQR, 0 to 1], P<0.001) and forced expiratory volume in one second (1.03 L [IQR, 0.52 to 1.36 L] vs. 1.98 L [IQR, 1.57 to 2.64 L], P=0.004) were significantly improved after intervention. There were no procedure-related acute complications and deaths.ConclusionRigid bronchoscopy with APC is an effective and safe procedure to alleviate central airway obstruction caused by tumors. |
topic |
Argon Plasma Coagulation Bronchoscopy Airway Obstruction |
url |
http://www.e-ceo.org/upload/pdf/ceo-8-396.pdf |
work_keys_str_mv |
AT boramlee usefulnessofrigidbronchoscopicinterventionusingargonplasmacoagulationforcentralairwaytumors AT injaeoh usefulnessofrigidbronchoscopicinterventionusingargonplasmacoagulationforcentralairwaytumors AT hosunglee usefulnessofrigidbronchoscopicinterventionusingargonplasmacoagulationforcentralairwaytumors AT heejungban usefulnessofrigidbronchoscopicinterventionusingargonplasmacoagulationforcentralairwaytumors AT kyusikkim usefulnessofrigidbronchoscopicinterventionusingargonplasmacoagulationforcentralairwaytumors AT yuilkim usefulnessofrigidbronchoscopicinterventionusingargonplasmacoagulationforcentralairwaytumors AT sungchullim usefulnessofrigidbronchoscopicinterventionusingargonplasmacoagulationforcentralairwaytumors AT youngchulkim usefulnessofrigidbronchoscopicinterventionusingargonplasmacoagulationforcentralairwaytumors AT yongwookpark usefulnessofrigidbronchoscopicinterventionusingargonplasmacoagulationforcentralairwaytumors AT yongsookwon usefulnessofrigidbronchoscopicinterventionusingargonplasmacoagulationforcentralairwaytumors |
_version_ |
1725852663795417088 |