The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: A systematic review

<p>Abstract</p> <p>Background</p> <p>The assessment of outcomes from the patient's perspective becomes more recognized in health care. Also in patients with chronic ankle instability, the degree of present impairments, disabilities and participation problems should...

Full description

Bibliographic Details
Main Authors: Asman Sara, Van Aerschot Lieve, Vaes Peter, Eechaute Christophe, Duquet William
Format: Article
Language:English
Published: BMC 2007-01-01
Series:BMC Musculoskeletal Disorders
Online Access:http://www.biomedcentral.com/1471-2474/8/6
id doaj-40820380543442b39b1669d22a073703
record_format Article
spelling doaj-40820380543442b39b1669d22a0737032020-11-24T22:05:00ZengBMCBMC Musculoskeletal Disorders1471-24742007-01-0181610.1186/1471-2474-8-6The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: A systematic reviewAsman SaraVan Aerschot LieveVaes PeterEechaute ChristopheDuquet William<p>Abstract</p> <p>Background</p> <p>The assessment of outcomes from the patient's perspective becomes more recognized in health care. Also in patients with chronic ankle instability, the degree of present impairments, disabilities and participation problems should be documented from the perspective of the patient. The decision about which patient-assessed instrument is most appropriate for clinical practice should be based upon systematic reviews. Only rating scales constructed for patients with acute ligament injuries were systematically reviewed in the past. The aim of this study was to review systematically the clinimetric qualities of patient-assessed instruments designed for patients with chronic ankle instability.</p> <p>Methods</p> <p>A computerized literature search of Medline, Embase, Cinahl, Web of Science, Sport Discus and the Cochrane Controlled Trial Register was performed to identify eligible instruments. Two reviewers independently evaluated the clinimetric qualities of the selected instruments using a criteria list. The inter-observer reliability of both the selection procedure and the clinimetric evaluation was calculated using modified kappa coefficients.</p> <p>Results</p> <p>The inter-observer reliability of the selection procedure was excellent (k = .86). Four instruments met the eligibility criteria: the Ankle Joint Functional Assessment Tool (AJFAT), the Functional Ankle Outcome Score (FAOS), the Foot and Ankle Disability Index (FADI) and the Functional Ankle Ability Measure (FAAM). The inter-observer reliability of the quality assessment was substantial to excellent (k between .64 and .88). Test-retest reliability was demonstrated for the FAOS, the FADI and the FAAM but not for the AJFAT. The FAOS and the FAAM met the criteria for content validity and construct validity. For none of the studied instruments, the internal consistency was sufficiently demonstrated. The presence of floor- and ceiling effects was assessed for the FAOS but ceiling effects were present for all subscales. Responsiveness was demonstrated for the AJFAT, FADI and the FAAM. Only for the FAAM, a minimal clinical important difference (MCID) was presented.</p> <p>Conclusion</p> <p>The FADI and the FAAM can be considered as the most appropriate, patient-assessed tools to quantify functional disabilities in patients with chronic ankle instability. The clinimetric qualities of the FAAM need to be further demonstrated in a specific population of patients with chronic ankle instability.</p> http://www.biomedcentral.com/1471-2474/8/6
collection DOAJ
language English
format Article
sources DOAJ
author Asman Sara
Van Aerschot Lieve
Vaes Peter
Eechaute Christophe
Duquet William
spellingShingle Asman Sara
Van Aerschot Lieve
Vaes Peter
Eechaute Christophe
Duquet William
The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: A systematic review
BMC Musculoskeletal Disorders
author_facet Asman Sara
Van Aerschot Lieve
Vaes Peter
Eechaute Christophe
Duquet William
author_sort Asman Sara
title The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: A systematic review
title_short The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: A systematic review
title_full The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: A systematic review
title_fullStr The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: A systematic review
title_full_unstemmed The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: A systematic review
title_sort clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: a systematic review
publisher BMC
series BMC Musculoskeletal Disorders
issn 1471-2474
publishDate 2007-01-01
description <p>Abstract</p> <p>Background</p> <p>The assessment of outcomes from the patient's perspective becomes more recognized in health care. Also in patients with chronic ankle instability, the degree of present impairments, disabilities and participation problems should be documented from the perspective of the patient. The decision about which patient-assessed instrument is most appropriate for clinical practice should be based upon systematic reviews. Only rating scales constructed for patients with acute ligament injuries were systematically reviewed in the past. The aim of this study was to review systematically the clinimetric qualities of patient-assessed instruments designed for patients with chronic ankle instability.</p> <p>Methods</p> <p>A computerized literature search of Medline, Embase, Cinahl, Web of Science, Sport Discus and the Cochrane Controlled Trial Register was performed to identify eligible instruments. Two reviewers independently evaluated the clinimetric qualities of the selected instruments using a criteria list. The inter-observer reliability of both the selection procedure and the clinimetric evaluation was calculated using modified kappa coefficients.</p> <p>Results</p> <p>The inter-observer reliability of the selection procedure was excellent (k = .86). Four instruments met the eligibility criteria: the Ankle Joint Functional Assessment Tool (AJFAT), the Functional Ankle Outcome Score (FAOS), the Foot and Ankle Disability Index (FADI) and the Functional Ankle Ability Measure (FAAM). The inter-observer reliability of the quality assessment was substantial to excellent (k between .64 and .88). Test-retest reliability was demonstrated for the FAOS, the FADI and the FAAM but not for the AJFAT. The FAOS and the FAAM met the criteria for content validity and construct validity. For none of the studied instruments, the internal consistency was sufficiently demonstrated. The presence of floor- and ceiling effects was assessed for the FAOS but ceiling effects were present for all subscales. Responsiveness was demonstrated for the AJFAT, FADI and the FAAM. Only for the FAAM, a minimal clinical important difference (MCID) was presented.</p> <p>Conclusion</p> <p>The FADI and the FAAM can be considered as the most appropriate, patient-assessed tools to quantify functional disabilities in patients with chronic ankle instability. The clinimetric qualities of the FAAM need to be further demonstrated in a specific population of patients with chronic ankle instability.</p>
url http://www.biomedcentral.com/1471-2474/8/6
work_keys_str_mv AT asmansara theclinimetricqualitiesofpatientassessedinstrumentsformeasuringchronicankleinstabilityasystematicreview
AT vanaerschotlieve theclinimetricqualitiesofpatientassessedinstrumentsformeasuringchronicankleinstabilityasystematicreview
AT vaespeter theclinimetricqualitiesofpatientassessedinstrumentsformeasuringchronicankleinstabilityasystematicreview
AT eechautechristophe theclinimetricqualitiesofpatientassessedinstrumentsformeasuringchronicankleinstabilityasystematicreview
AT duquetwilliam theclinimetricqualitiesofpatientassessedinstrumentsformeasuringchronicankleinstabilityasystematicreview
AT asmansara clinimetricqualitiesofpatientassessedinstrumentsformeasuringchronicankleinstabilityasystematicreview
AT vanaerschotlieve clinimetricqualitiesofpatientassessedinstrumentsformeasuringchronicankleinstabilityasystematicreview
AT vaespeter clinimetricqualitiesofpatientassessedinstrumentsformeasuringchronicankleinstabilityasystematicreview
AT eechautechristophe clinimetricqualitiesofpatientassessedinstrumentsformeasuringchronicankleinstabilityasystematicreview
AT duquetwilliam clinimetricqualitiesofpatientassessedinstrumentsformeasuringchronicankleinstabilityasystematicreview
_version_ 1725827744641581056