Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes

A modified simplex algorithm was used to optimize a system of preconcentration for cadmium determination in samples of sediments, cigarettes and food using flame atomic absorption spectrometry. The preconcentration system is based on the sorption of cadmium in a minicolumn packed with Amberlite XAD-...

Full description

Bibliographic Details
Main Authors: QUEILA O. SANTOS, ISLANIA MORENO, LEANDRO DOS SANTOS, ALDENOR G. SANTOS, VALDINEI S. SOUZA, MARCOS A. BEZERRA
Format: Article
Language:English
Published: Academia Brasileira de Ciências 2016-06-01
Series:Anais da Academia Brasileira de Ciências
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652016000300791&lng=en&tlng=en
id doaj-403a660ba7044815b8c72b67044ad140
record_format Article
spelling doaj-403a660ba7044815b8c72b67044ad1402020-11-24T22:52:27ZengAcademia Brasileira de CiênciasAnais da Academia Brasileira de Ciências1678-26902016-06-0188279179910.1590/0001-3765201620150209S0001-37652016000300791Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettesQUEILA O. SANTOSISLANIA MORENOLEANDRO DOS SANTOSALDENOR G. SANTOSVALDINEI S. SOUZAMARCOS A. BEZERRAA modified simplex algorithm was used to optimize a system of preconcentration for cadmium determination in samples of sediments, cigarettes and food using flame atomic absorption spectrometry. The preconcentration system is based on the sorption of cadmium in a minicolumn packed with Amberlite XAD-2 resin functionalized with 3,4-dihydroxybenzoic acid (DHB). The optimized variables were pH and sampling flow rate and the optimum conditions found for these variables were, respectively 8.7 and 8.8 mL min-1. The developed system showed a preconcentration factor of 15.3, detection limit of 0.49 µg L-1, quantification limit of 1.65 µg L-1 and precision expressed as relative standard deviation (% RSD, n=10) of 5.9. The accuracy of the method was checked by analysis of estuary sediment certified reference material (NIST 1646-1). The cadmium concentrations found in sediment samples ranged from 1.73 and 1.90 µg g-1. In cigarette samples the results were 0.085 and 0.193 µg g-1, and in food samples (coriander and lettuce) the concentrations found of this metal were, respectively, 0.33 and 0.12 µg g-1.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652016000300791&lng=en&tlng=enotimização simplexpré-concentraçãocádmiosedimentoscigarrosalimentos
collection DOAJ
language English
format Article
sources DOAJ
author QUEILA O. SANTOS
ISLANIA MORENO
LEANDRO DOS SANTOS
ALDENOR G. SANTOS
VALDINEI S. SOUZA
MARCOS A. BEZERRA
spellingShingle QUEILA O. SANTOS
ISLANIA MORENO
LEANDRO DOS SANTOS
ALDENOR G. SANTOS
VALDINEI S. SOUZA
MARCOS A. BEZERRA
Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
Anais da Academia Brasileira de Ciências
otimização simplex
pré-concentração
cádmio
sedimentos
cigarros
alimentos
author_facet QUEILA O. SANTOS
ISLANIA MORENO
LEANDRO DOS SANTOS
ALDENOR G. SANTOS
VALDINEI S. SOUZA
MARCOS A. BEZERRA
author_sort QUEILA O. SANTOS
title Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
title_short Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
title_full Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
title_fullStr Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
title_full_unstemmed Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
title_sort application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
publisher Academia Brasileira de Ciências
series Anais da Academia Brasileira de Ciências
issn 1678-2690
publishDate 2016-06-01
description A modified simplex algorithm was used to optimize a system of preconcentration for cadmium determination in samples of sediments, cigarettes and food using flame atomic absorption spectrometry. The preconcentration system is based on the sorption of cadmium in a minicolumn packed with Amberlite XAD-2 resin functionalized with 3,4-dihydroxybenzoic acid (DHB). The optimized variables were pH and sampling flow rate and the optimum conditions found for these variables were, respectively 8.7 and 8.8 mL min-1. The developed system showed a preconcentration factor of 15.3, detection limit of 0.49 µg L-1, quantification limit of 1.65 µg L-1 and precision expressed as relative standard deviation (% RSD, n=10) of 5.9. The accuracy of the method was checked by analysis of estuary sediment certified reference material (NIST 1646-1). The cadmium concentrations found in sediment samples ranged from 1.73 and 1.90 µg g-1. In cigarette samples the results were 0.085 and 0.193 µg g-1, and in food samples (coriander and lettuce) the concentrations found of this metal were, respectively, 0.33 and 0.12 µg g-1.
topic otimização simplex
pré-concentração
cádmio
sedimentos
cigarros
alimentos
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652016000300791&lng=en&tlng=en
work_keys_str_mv AT queilaosantos applicationofmodifiedsimplexonthedevelopmentofapreconcentrationsystemforcadmiumdeterminationinsedimentsfoodandcigarettes
AT islaniamoreno applicationofmodifiedsimplexonthedevelopmentofapreconcentrationsystemforcadmiumdeterminationinsedimentsfoodandcigarettes
AT leandrodossantos applicationofmodifiedsimplexonthedevelopmentofapreconcentrationsystemforcadmiumdeterminationinsedimentsfoodandcigarettes
AT aldenorgsantos applicationofmodifiedsimplexonthedevelopmentofapreconcentrationsystemforcadmiumdeterminationinsedimentsfoodandcigarettes
AT valdineissouza applicationofmodifiedsimplexonthedevelopmentofapreconcentrationsystemforcadmiumdeterminationinsedimentsfoodandcigarettes
AT marcosabezerra applicationofmodifiedsimplexonthedevelopmentofapreconcentrationsystemforcadmiumdeterminationinsedimentsfoodandcigarettes
_version_ 1725666073270812672