First-Attempt Endotracheal Intubation Success Rate Using A Telescoping Steel Bougie
Background There has been a renewed interest in using the plastic intubation bougie to facilitate first-attempt endotracheal intubation success. The sterile single-use telescopic steel bougie (AIROD) was invented to overcome the limitations of the plastic bougie which is easily deformed during stor...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Arizona Thoracic Society
2021-01-01
|
Series: | Southwest Journal of Pulmonary and Critical Care |
Subjects: | |
Online Access: | https://www.swjpcc.com/critical-care/2021/1/25/first-attempt-endotracheal-intubation-success-rate-using-a-t.html |
id |
doaj-4018033166eb480cb04b70a86a80c6db |
---|---|
record_format |
Article |
spelling |
doaj-4018033166eb480cb04b70a86a80c6db2021-01-25T15:41:03ZengArizona Thoracic SocietySouthwest Journal of Pulmonary and Critical Care2160-67732021-01-01221364010.13175/swjpcc004-21First-Attempt Endotracheal Intubation Success Rate Using A Telescoping Steel BougieEvan D. Schmitz0La Jolla, CA USABackground There has been a renewed interest in using the plastic intubation bougie to facilitate first-attempt endotracheal intubation success. The sterile single-use telescopic steel bougie (AIROD) was invented to overcome the limitations of the plastic bougie which is easily deformed during storage. Methods This is a retrospective study involving critically ill patients who were intubated with the AIROD in the intensive care unit at a single institution. The purpose of this case series is to compare the success rate of the AIROD to the generally accepted success rate for the traditional plastic bougie of 96%. Results A total of 54 patients were enrolled at a single ICU over a 10 months period. All patients were critically ill with 76% having a difficult airway, Cormack-Lehane grade view 2 or greater in 60%, and ARDS secondary to COVID-19 in 54%. The primary outcome of first-attempt intubation success in critically ill patients intubated in the ICU with the AIROD was 97% with a 95% confidence interval of 0.89 to 0.99. The average time for intubation of all airway classifications was 15 seconds. Conclusion The AIROD first-attempt intubation success rate was found to be similar to the rate for the traditional plastic bougie. https://www.swjpcc.com/critical-care/2021/1/25/first-attempt-endotracheal-intubation-success-rate-using-a-t.htmlbougieairodintubationicusuccess ratedifficult airwaycomplicationstimefirst-passcovd-19 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Evan D. Schmitz |
spellingShingle |
Evan D. Schmitz First-Attempt Endotracheal Intubation Success Rate Using A Telescoping Steel Bougie Southwest Journal of Pulmonary and Critical Care bougie airod intubation icu success rate difficult airway complications time first-pass covd-19 |
author_facet |
Evan D. Schmitz |
author_sort |
Evan D. Schmitz |
title |
First-Attempt Endotracheal Intubation Success Rate Using A Telescoping Steel Bougie |
title_short |
First-Attempt Endotracheal Intubation Success Rate Using A Telescoping Steel Bougie |
title_full |
First-Attempt Endotracheal Intubation Success Rate Using A Telescoping Steel Bougie |
title_fullStr |
First-Attempt Endotracheal Intubation Success Rate Using A Telescoping Steel Bougie |
title_full_unstemmed |
First-Attempt Endotracheal Intubation Success Rate Using A Telescoping Steel Bougie |
title_sort |
first-attempt endotracheal intubation success rate using a telescoping steel bougie |
publisher |
Arizona Thoracic Society |
series |
Southwest Journal of Pulmonary and Critical Care |
issn |
2160-6773 |
publishDate |
2021-01-01 |
description |
Background
There has been a renewed interest in using the plastic intubation bougie to facilitate first-attempt endotracheal intubation success. The sterile single-use telescopic steel bougie (AIROD) was invented to overcome the limitations of the plastic bougie which is easily deformed during storage.
Methods
This is a retrospective study involving critically ill patients who were intubated with the AIROD in the intensive care unit at a single institution. The purpose of this case series is to compare the success rate of the AIROD to the generally accepted success rate for the traditional plastic bougie of 96%.
Results
A total of 54 patients were enrolled at a single ICU over a 10 months period. All patients were critically ill with 76% having a difficult airway, Cormack-Lehane grade view 2 or greater in 60%, and ARDS secondary to COVID-19 in 54%. The primary outcome of first-attempt intubation success in critically ill patients intubated in the ICU with the AIROD was 97% with a 95% confidence interval of 0.89 to 0.99. The average time for intubation of all airway classifications was 15 seconds.
Conclusion
The AIROD first-attempt intubation success rate was found to be similar to the rate for the traditional plastic bougie. |
topic |
bougie airod intubation icu success rate difficult airway complications time first-pass covd-19 |
url |
https://www.swjpcc.com/critical-care/2021/1/25/first-attempt-endotracheal-intubation-success-rate-using-a-t.html |
work_keys_str_mv |
AT evandschmitz firstattemptendotrachealintubationsuccessrateusingatelescopingsteelbougie |
_version_ |
1724323904169705472 |