A Model for the Spacing of Quicklime Pile to Treat High Water Content Loess

There has been a long history for foundation treatment by quicklime pile, but as for establishing a more precise model formula used by actual construction, further research is needed to be done at present. Therefore, how to quantitate the factors affecting pile spacing is of great reference value fo...

Full description

Bibliographic Details
Main Authors: Hong Guo, Yalin Nan, Rui Guo, Jiangtao Fu
Format: Article
Language:English
Published: Hindawi Limited 2020-01-01
Series:Mathematical Problems in Engineering
Online Access:http://dx.doi.org/10.1155/2020/9439624
id doaj-3fed6c8ecd824c0bb18b71f3ca3e59cb
record_format Article
spelling doaj-3fed6c8ecd824c0bb18b71f3ca3e59cb2020-11-25T03:07:53ZengHindawi LimitedMathematical Problems in Engineering1024-123X1563-51472020-01-01202010.1155/2020/94396249439624A Model for the Spacing of Quicklime Pile to Treat High Water Content LoessHong Guo0Yalin Nan1Rui Guo2Jiangtao Fu3School of Civil Engineering and Architecture, Shaanxi University of Technology, Hanzhong 723001, ChinaChina Electronic Research Institute of Engineering Investigations and Design, Xi’an 710054, ChinaSchool of Civil Engineering and Architecture, Shaanxi University of Technology, Hanzhong 723001, ChinaSchool of Civil Engineering and Architecture, Shaanxi University of Technology, Hanzhong 723001, ChinaThere has been a long history for foundation treatment by quicklime pile, but as for establishing a more precise model formula used by actual construction, further research is needed to be done at present. Therefore, how to quantitate the factors affecting pile spacing is of great reference value for both actual constructions and theoretical studies. Based on the reference formula for handling weak foundation by lime pile and the practical problems in the western region, mathematical model analysis method is used to get a new model for high water content loess foundation treatment after considering the factors such as pile expanding, construction method, piles arrangement, and calcium oxide content. In this model, pile spacing coefficient is created and the model formula for different construction methods and different pile arrangements is also given. As a result, the reference formula used in high water content loess is somewhat conservative. The new model is also verified to be rational by the actual works at the end of the paper.http://dx.doi.org/10.1155/2020/9439624
collection DOAJ
language English
format Article
sources DOAJ
author Hong Guo
Yalin Nan
Rui Guo
Jiangtao Fu
spellingShingle Hong Guo
Yalin Nan
Rui Guo
Jiangtao Fu
A Model for the Spacing of Quicklime Pile to Treat High Water Content Loess
Mathematical Problems in Engineering
author_facet Hong Guo
Yalin Nan
Rui Guo
Jiangtao Fu
author_sort Hong Guo
title A Model for the Spacing of Quicklime Pile to Treat High Water Content Loess
title_short A Model for the Spacing of Quicklime Pile to Treat High Water Content Loess
title_full A Model for the Spacing of Quicklime Pile to Treat High Water Content Loess
title_fullStr A Model for the Spacing of Quicklime Pile to Treat High Water Content Loess
title_full_unstemmed A Model for the Spacing of Quicklime Pile to Treat High Water Content Loess
title_sort model for the spacing of quicklime pile to treat high water content loess
publisher Hindawi Limited
series Mathematical Problems in Engineering
issn 1024-123X
1563-5147
publishDate 2020-01-01
description There has been a long history for foundation treatment by quicklime pile, but as for establishing a more precise model formula used by actual construction, further research is needed to be done at present. Therefore, how to quantitate the factors affecting pile spacing is of great reference value for both actual constructions and theoretical studies. Based on the reference formula for handling weak foundation by lime pile and the practical problems in the western region, mathematical model analysis method is used to get a new model for high water content loess foundation treatment after considering the factors such as pile expanding, construction method, piles arrangement, and calcium oxide content. In this model, pile spacing coefficient is created and the model formula for different construction methods and different pile arrangements is also given. As a result, the reference formula used in high water content loess is somewhat conservative. The new model is also verified to be rational by the actual works at the end of the paper.
url http://dx.doi.org/10.1155/2020/9439624
work_keys_str_mv AT hongguo amodelforthespacingofquicklimepiletotreathighwatercontentloess
AT yalinnan amodelforthespacingofquicklimepiletotreathighwatercontentloess
AT ruiguo amodelforthespacingofquicklimepiletotreathighwatercontentloess
AT jiangtaofu amodelforthespacingofquicklimepiletotreathighwatercontentloess
AT hongguo modelforthespacingofquicklimepiletotreathighwatercontentloess
AT yalinnan modelforthespacingofquicklimepiletotreathighwatercontentloess
AT ruiguo modelforthespacingofquicklimepiletotreathighwatercontentloess
AT jiangtaofu modelforthespacingofquicklimepiletotreathighwatercontentloess
_version_ 1715298276506337280