Determining single-phase earth fault location with applying short-term double earth fault
The single-phase earth faults location are the predominant type of damage in distribution networks of 6-35 kV. The problem of remotely determining the fault location during single-phase earth faults has not definitely accepted practical and accurate solution. The article proposes and substantiates t...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2019-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/65/e3sconf_rses2019_01041.pdf |
id |
doaj-3fb2f2edcc51474eaff71922232a2daf |
---|---|
record_format |
Article |
spelling |
doaj-3fb2f2edcc51474eaff71922232a2daf2021-04-02T14:25:06ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011390104110.1051/e3sconf/201913901041e3sconf_rses2019_01041Determining single-phase earth fault location with applying short-term double earth faultKulikov A.L.0Osokin V.Ju.1Bezdushniy D.I.2NSTU n.a. R.E. Alekseev, Nizhniy NovgorodNSTU n.a. R.E. Alekseev, Nizhniy NovgorodNSTU n.a. R.E. Alekseev, Nizhniy NovgorodThe single-phase earth faults location are the predominant type of damage in distribution networks of 6-35 kV. The problem of remotely determining the fault location during single-phase earth faults has not definitely accepted practical and accurate solution. The article proposes and substantiates the intellectual methods of determining the fault location with using artificial introduction of short-term double earth faults. In the future by recorded oscillograms of currents and voltages, an accurate calculation of the distance to the damage is assumed.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/65/e3sconf_rses2019_01041.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Kulikov A.L. Osokin V.Ju. Bezdushniy D.I. |
spellingShingle |
Kulikov A.L. Osokin V.Ju. Bezdushniy D.I. Determining single-phase earth fault location with applying short-term double earth fault E3S Web of Conferences |
author_facet |
Kulikov A.L. Osokin V.Ju. Bezdushniy D.I. |
author_sort |
Kulikov A.L. |
title |
Determining single-phase earth fault location with applying short-term double earth fault |
title_short |
Determining single-phase earth fault location with applying short-term double earth fault |
title_full |
Determining single-phase earth fault location with applying short-term double earth fault |
title_fullStr |
Determining single-phase earth fault location with applying short-term double earth fault |
title_full_unstemmed |
Determining single-phase earth fault location with applying short-term double earth fault |
title_sort |
determining single-phase earth fault location with applying short-term double earth fault |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2019-01-01 |
description |
The single-phase earth faults location are the predominant type of damage in distribution networks of 6-35 kV. The problem of remotely determining the fault location during single-phase earth faults has not definitely accepted practical and accurate solution. The article proposes and substantiates the intellectual methods of determining the fault location with using artificial introduction of short-term double earth faults. In the future by recorded oscillograms of currents and voltages, an accurate calculation of the distance to the damage is assumed. |
url |
https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/65/e3sconf_rses2019_01041.pdf |
work_keys_str_mv |
AT kulikoval determiningsinglephaseearthfaultlocationwithapplyingshorttermdoubleearthfault AT osokinvju determiningsinglephaseearthfaultlocationwithapplyingshorttermdoubleearthfault AT bezdushniydi determiningsinglephaseearthfaultlocationwithapplyingshorttermdoubleearthfault |
_version_ |
1721562325467529216 |