Determining single-phase earth fault location with applying short-term double earth fault

The single-phase earth faults location are the predominant type of damage in distribution networks of 6-35 kV. The problem of remotely determining the fault location during single-phase earth faults has not definitely accepted practical and accurate solution. The article proposes and substantiates t...

Full description

Bibliographic Details
Main Authors: Kulikov A.L., Osokin V.Ju., Bezdushniy D.I.
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/65/e3sconf_rses2019_01041.pdf
id doaj-3fb2f2edcc51474eaff71922232a2daf
record_format Article
spelling doaj-3fb2f2edcc51474eaff71922232a2daf2021-04-02T14:25:06ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011390104110.1051/e3sconf/201913901041e3sconf_rses2019_01041Determining single-phase earth fault location with applying short-term double earth faultKulikov A.L.0Osokin V.Ju.1Bezdushniy D.I.2NSTU n.a. R.E. Alekseev, Nizhniy NovgorodNSTU n.a. R.E. Alekseev, Nizhniy NovgorodNSTU n.a. R.E. Alekseev, Nizhniy NovgorodThe single-phase earth faults location are the predominant type of damage in distribution networks of 6-35 kV. The problem of remotely determining the fault location during single-phase earth faults has not definitely accepted practical and accurate solution. The article proposes and substantiates the intellectual methods of determining the fault location with using artificial introduction of short-term double earth faults. In the future by recorded oscillograms of currents and voltages, an accurate calculation of the distance to the damage is assumed.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/65/e3sconf_rses2019_01041.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Kulikov A.L.
Osokin V.Ju.
Bezdushniy D.I.
spellingShingle Kulikov A.L.
Osokin V.Ju.
Bezdushniy D.I.
Determining single-phase earth fault location with applying short-term double earth fault
E3S Web of Conferences
author_facet Kulikov A.L.
Osokin V.Ju.
Bezdushniy D.I.
author_sort Kulikov A.L.
title Determining single-phase earth fault location with applying short-term double earth fault
title_short Determining single-phase earth fault location with applying short-term double earth fault
title_full Determining single-phase earth fault location with applying short-term double earth fault
title_fullStr Determining single-phase earth fault location with applying short-term double earth fault
title_full_unstemmed Determining single-phase earth fault location with applying short-term double earth fault
title_sort determining single-phase earth fault location with applying short-term double earth fault
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2019-01-01
description The single-phase earth faults location are the predominant type of damage in distribution networks of 6-35 kV. The problem of remotely determining the fault location during single-phase earth faults has not definitely accepted practical and accurate solution. The article proposes and substantiates the intellectual methods of determining the fault location with using artificial introduction of short-term double earth faults. In the future by recorded oscillograms of currents and voltages, an accurate calculation of the distance to the damage is assumed.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/65/e3sconf_rses2019_01041.pdf
work_keys_str_mv AT kulikoval determiningsinglephaseearthfaultlocationwithapplyingshorttermdoubleearthfault
AT osokinvju determiningsinglephaseearthfaultlocationwithapplyingshorttermdoubleearthfault
AT bezdushniydi determiningsinglephaseearthfaultlocationwithapplyingshorttermdoubleearthfault
_version_ 1721562325467529216