Tables for near vision examination in low vision patients
Purpose: to design methods and algorithms of technical means selection for near visual work in low vision patients. We propose tables to measure near vision acuity ranging from 0.01 to 0.8, with test character sizes varying in logarithmic progression with 1.26 denominator. The tables help determine...
Main Author: | |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Real Time Ltd
2019-03-01
|
Series: | Российский офтальмологический журнал |
Subjects: | |
Online Access: | https://roj.igb.ru/jour/article/view/228 |
id |
doaj-3f8e687fe6cb46fd82f95d5d237c5c04 |
---|---|
record_format |
Article |
spelling |
doaj-3f8e687fe6cb46fd82f95d5d237c5c042021-07-28T13:01:39ZrusReal Time LtdРоссийский офтальмологический журнал2072-00762587-57602019-03-01121869110.21516/2072-0076-2019-12-1-86-91210Tables for near vision examination in low vision patientsT. S. Egorova0Moscow Helmholtz Research Institute of Eye DiseasesPurpose: to design methods and algorithms of technical means selection for near visual work in low vision patients. We propose tables to measure near vision acuity ranging from 0.01 to 0.8, with test character sizes varying in logarithmic progression with 1.26 denominator. The tables help determine the minimal size of readable font = the reading threshold and magnification degree needed to ensure the reading of a normal font. To choose the optimal magnifier, a quantitative criterion was chosen — the reading rate. Due to these methods we were able to recommend the most effective technical means of rehabilitation for monocular or binocular use depending on the reading threshold, reading rate, the presence of ophthalmic pathologies and the patient’s age.https://roj.igb.ru/jour/article/view/228low visiontables for near vision visometryreading thresholdspeed of reading ratemagnification degreemagnifier type |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
T. S. Egorova |
spellingShingle |
T. S. Egorova Tables for near vision examination in low vision patients Российский офтальмологический журнал low vision tables for near vision visometry reading threshold speed of reading rate magnification degree magnifier type |
author_facet |
T. S. Egorova |
author_sort |
T. S. Egorova |
title |
Tables for near vision examination in low vision patients |
title_short |
Tables for near vision examination in low vision patients |
title_full |
Tables for near vision examination in low vision patients |
title_fullStr |
Tables for near vision examination in low vision patients |
title_full_unstemmed |
Tables for near vision examination in low vision patients |
title_sort |
tables for near vision examination in low vision patients |
publisher |
Real Time Ltd |
series |
Российский офтальмологический журнал |
issn |
2072-0076 2587-5760 |
publishDate |
2019-03-01 |
description |
Purpose: to design methods and algorithms of technical means selection for near visual work in low vision patients. We propose tables to measure near vision acuity ranging from 0.01 to 0.8, with test character sizes varying in logarithmic progression with 1.26 denominator. The tables help determine the minimal size of readable font = the reading threshold and magnification degree needed to ensure the reading of a normal font. To choose the optimal magnifier, a quantitative criterion was chosen — the reading rate. Due to these methods we were able to recommend the most effective technical means of rehabilitation for monocular or binocular use depending on the reading threshold, reading rate, the presence of ophthalmic pathologies and the patient’s age. |
topic |
low vision tables for near vision visometry reading threshold speed of reading rate magnification degree magnifier type |
url |
https://roj.igb.ru/jour/article/view/228 |
work_keys_str_mv |
AT tsegorova tablesfornearvisionexaminationinlowvisionpatients |
_version_ |
1721277193477160960 |