Experimental study of the protective effect of autoantibodies against the β3-adrenorceptor on heart function of rat model with heart failure

Objective: To explore the correlation of gastroesophageal reflux with ventilator-associated pneumonia (VAP). Methods: A total of 84 patients who were performed with mechanical assisted ventilation in our hospital were included in the study. The pharyngeal and tracheal secretions 2 d (T1), 4 d (T2...

Full description

Bibliographic Details
Main Author: Yin-Wen Xia
Format: Article
Language:English
Published: Editorial Board of Journal of Hainan Medical University 2016-02-01
Series:Journal of Hainan Medical University
Subjects:
VAP
Online Access:http://www.jhmuweb.net/PDF/201604/3.pdf
id doaj-3f0ac84ce88a498192be3afeabe22fbd
record_format Article
spelling doaj-3f0ac84ce88a498192be3afeabe22fbd2020-11-25T00:18:31ZengEditorial Board of Journal of Hainan Medical UniversityJournal of Hainan Medical University1007-12371007-12372016-02-0122 4912Experimental study of the protective effect of autoantibodies against the β3-adrenorceptor on heart function of rat model with heart failureYin-Wen Xia0Department of Cardiovascular Medicine, Hanchuan People's Hospital, Hanchuan City, Hubei Province, 431600Objective: To explore the correlation of gastroesophageal reflux with ventilator-associated pneumonia (VAP). Methods: A total of 84 patients who were performed with mechanical assisted ventilation in our hospital were included in the study. The pharyngeal and tracheal secretions 2 d (T1), 4 d (T2), and 6 d (T3) after mechanical ventilation were collected, respectively. ELISA was used to detect the pepsin concentration. The clinical pulmonary infection score (CPIS) was performed to the patients in order to analyze the correlation of pepsin concentration with CPIS. Results: The positive rate of pharyngeal pepsin at T1 was 16.7%, at T2 was 54.8%, and at T3 was 78.6%. The positive rate of pepsin was increased with the extending of mechanical ventilation time. The comparison of pepsin concentration in the pharyngeal secretions at T1 between the VAP patients and non-VAP patients was not statistically significant, but the pepsin concentration in the tracheal secretions was significantly higher than that in the non-VAP patients. The pepsin concentration in the pharyngeal and tracheal secretions at T2 and T3 in the VAP patients was significantly higher than that in the non-VAP patients. The pepsin concentration in the tracheal secretions in the VAP patients was associated with CPIS. Conclusions: The positive rate of pepsin concentration in the pharyngeal and tracheal secretions in the VAP patients is increased with the extending of mechanical ventilation time. The positive rate of pepsin concentration in the tracheal secretions at each timing point in the VAP patients is significantly higher than that in the non-VAP patients. The pepsin concentration in the pharyngeal and tracheal secretions in the VAP patients is positively correlated with CPIS.http://www.jhmuweb.net/PDF/201604/3.pdfVAPGastroesophageal refluxPepsinCPIS.
collection DOAJ
language English
format Article
sources DOAJ
author Yin-Wen Xia
spellingShingle Yin-Wen Xia
Experimental study of the protective effect of autoantibodies against the β3-adrenorceptor on heart function of rat model with heart failure
Journal of Hainan Medical University
VAP
Gastroesophageal reflux
Pepsin
CPIS.
author_facet Yin-Wen Xia
author_sort Yin-Wen Xia
title Experimental study of the protective effect of autoantibodies against the β3-adrenorceptor on heart function of rat model with heart failure
title_short Experimental study of the protective effect of autoantibodies against the β3-adrenorceptor on heart function of rat model with heart failure
title_full Experimental study of the protective effect of autoantibodies against the β3-adrenorceptor on heart function of rat model with heart failure
title_fullStr Experimental study of the protective effect of autoantibodies against the β3-adrenorceptor on heart function of rat model with heart failure
title_full_unstemmed Experimental study of the protective effect of autoantibodies against the β3-adrenorceptor on heart function of rat model with heart failure
title_sort experimental study of the protective effect of autoantibodies against the β3-adrenorceptor on heart function of rat model with heart failure
publisher Editorial Board of Journal of Hainan Medical University
series Journal of Hainan Medical University
issn 1007-1237
1007-1237
publishDate 2016-02-01
description Objective: To explore the correlation of gastroesophageal reflux with ventilator-associated pneumonia (VAP). Methods: A total of 84 patients who were performed with mechanical assisted ventilation in our hospital were included in the study. The pharyngeal and tracheal secretions 2 d (T1), 4 d (T2), and 6 d (T3) after mechanical ventilation were collected, respectively. ELISA was used to detect the pepsin concentration. The clinical pulmonary infection score (CPIS) was performed to the patients in order to analyze the correlation of pepsin concentration with CPIS. Results: The positive rate of pharyngeal pepsin at T1 was 16.7%, at T2 was 54.8%, and at T3 was 78.6%. The positive rate of pepsin was increased with the extending of mechanical ventilation time. The comparison of pepsin concentration in the pharyngeal secretions at T1 between the VAP patients and non-VAP patients was not statistically significant, but the pepsin concentration in the tracheal secretions was significantly higher than that in the non-VAP patients. The pepsin concentration in the pharyngeal and tracheal secretions at T2 and T3 in the VAP patients was significantly higher than that in the non-VAP patients. The pepsin concentration in the tracheal secretions in the VAP patients was associated with CPIS. Conclusions: The positive rate of pepsin concentration in the pharyngeal and tracheal secretions in the VAP patients is increased with the extending of mechanical ventilation time. The positive rate of pepsin concentration in the tracheal secretions at each timing point in the VAP patients is significantly higher than that in the non-VAP patients. The pepsin concentration in the pharyngeal and tracheal secretions in the VAP patients is positively correlated with CPIS.
topic VAP
Gastroesophageal reflux
Pepsin
CPIS.
url http://www.jhmuweb.net/PDF/201604/3.pdf
work_keys_str_mv AT yinwenxia experimentalstudyoftheprotectiveeffectofautoantibodiesagainsttheb3adrenorceptoronheartfunctionofratmodelwithheartfailure
_version_ 1725376082017779712