Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate

Purpose: This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostatebrachytherapy, biopsy and other interventional procedures. Further...

Full description

Bibliographic Details
Main Authors: Dimos Baltas, George Sakas, Pawel Zogal, Vasiliki Kefala, Zaira Katsilieri, Saeed Butt, Natasa Milickovic, Stefanos Diamantopoulos
Format: Article
Language:English
Published: Termedia Publishing House 2011-12-01
Series:Journal of Contemporary Brachytherapy
Subjects:
Online Access:http://www.termedia.pl/Physics-Contributions-Effect-of-using-different-U-S-probe-Standoff-materials-in-image-geometry-for-interventional-procedures-the-example-of-prostate,54,17926,1,1.html
id doaj-3e5e00a4191d4b16ad4ba78b8076b028
record_format Article
spelling doaj-3e5e00a4191d4b16ad4ba78b8076b0282020-11-24T20:46:23ZengTermedia Publishing HouseJournal of Contemporary Brachytherapy1689-832X2081-28412011-12-0134209219Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostateDimos BaltasGeorge SakasPawel ZogalVasiliki KefalaZaira KatsilieriSaeed ButtNatasa MilickovicStefanos DiamantopoulosPurpose: This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostatebrachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation of currently established waterbathbased quality assurance (QA) procedures is presented. Material and methods: Image acquisitions of an ultrasound QA setup were carried out at 5 MHz and 7 MHz. The U/Sprobe was covered by EA 4015 Silicone Standoff kit, or UA0059 Endocavity balloon filled either with water or one ofthe following: 40 ml of Endosgel®, Instillagel®, Ultraschall gel or Space OAR™ gel. The differences between imageswere recorded. Consequently, the dosimetric impact of the observed image distortion was investigated, using a tissueequivalent ultrasound prostate phantom – Model number 053 (CIRS Inc., Norfolk, VA, USA). Results: By using the EA 4015 Silicone Standoff kit in normal water with sound speed of 1525 m/s, a 3 mm needleshift was observed. The expansion of objects appeared in radial direction. The shift deforms also the PTV (prostate inour case) and other organs at risk (OARs) in the same way leading to overestimation of volume and underestimationof the dose. On the other hand, Instillagel® and Space OAR™ “shrinks” objects in an ultrasound image for 0.65 mm and0.40 mm, respectively. Conclusions: The use of EA 4015 Silicone Standoff kit for image acquisition, leads to erroneous contouring of PTVand OARs and reconstruction and placement of catheters, which results to incorrect dose calculation during prostatebrachytherapy. Moreover, the reliability of QA procedures lies mostly in the right temperature of the water used foraccurate simulation of real conditions of transrectal ultrasound imaging.http://www.termedia.pl/Physics-Contributions-Effect-of-using-different-U-S-probe-Standoff-materials-in-image-geometry-for-interventional-procedures-the-example-of-prostate,54,17926,1,1.htmlultrasoundneedle displacementimage distortionprostate brachytherapy
collection DOAJ
language English
format Article
sources DOAJ
author Dimos Baltas
George Sakas
Pawel Zogal
Vasiliki Kefala
Zaira Katsilieri
Saeed Butt
Natasa Milickovic
Stefanos Diamantopoulos
spellingShingle Dimos Baltas
George Sakas
Pawel Zogal
Vasiliki Kefala
Zaira Katsilieri
Saeed Butt
Natasa Milickovic
Stefanos Diamantopoulos
Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate
Journal of Contemporary Brachytherapy
ultrasound
needle displacement
image distortion
prostate brachytherapy
author_facet Dimos Baltas
George Sakas
Pawel Zogal
Vasiliki Kefala
Zaira Katsilieri
Saeed Butt
Natasa Milickovic
Stefanos Diamantopoulos
author_sort Dimos Baltas
title Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate
title_short Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate
title_full Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate
title_fullStr Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate
title_full_unstemmed Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate
title_sort effect of using different u/s probe standoff materials in image geometry for interventional procedures: the example of prostate
publisher Termedia Publishing House
series Journal of Contemporary Brachytherapy
issn 1689-832X
2081-2841
publishDate 2011-12-01
description Purpose: This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostatebrachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation of currently established waterbathbased quality assurance (QA) procedures is presented. Material and methods: Image acquisitions of an ultrasound QA setup were carried out at 5 MHz and 7 MHz. The U/Sprobe was covered by EA 4015 Silicone Standoff kit, or UA0059 Endocavity balloon filled either with water or one ofthe following: 40 ml of Endosgel®, Instillagel®, Ultraschall gel or Space OAR™ gel. The differences between imageswere recorded. Consequently, the dosimetric impact of the observed image distortion was investigated, using a tissueequivalent ultrasound prostate phantom – Model number 053 (CIRS Inc., Norfolk, VA, USA). Results: By using the EA 4015 Silicone Standoff kit in normal water with sound speed of 1525 m/s, a 3 mm needleshift was observed. The expansion of objects appeared in radial direction. The shift deforms also the PTV (prostate inour case) and other organs at risk (OARs) in the same way leading to overestimation of volume and underestimationof the dose. On the other hand, Instillagel® and Space OAR™ “shrinks” objects in an ultrasound image for 0.65 mm and0.40 mm, respectively. Conclusions: The use of EA 4015 Silicone Standoff kit for image acquisition, leads to erroneous contouring of PTVand OARs and reconstruction and placement of catheters, which results to incorrect dose calculation during prostatebrachytherapy. Moreover, the reliability of QA procedures lies mostly in the right temperature of the water used foraccurate simulation of real conditions of transrectal ultrasound imaging.
topic ultrasound
needle displacement
image distortion
prostate brachytherapy
url http://www.termedia.pl/Physics-Contributions-Effect-of-using-different-U-S-probe-Standoff-materials-in-image-geometry-for-interventional-procedures-the-example-of-prostate,54,17926,1,1.html
work_keys_str_mv AT dimosbaltas effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate
AT georgesakas effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate
AT pawelzogal effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate
AT vasilikikefala effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate
AT zairakatsilieri effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate
AT saeedbutt effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate
AT natasamilickovic effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate
AT stefanosdiamantopoulos effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate
_version_ 1716812826382696448