Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate
Purpose: This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostatebrachytherapy, biopsy and other interventional procedures. Further...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Termedia Publishing House
2011-12-01
|
Series: | Journal of Contemporary Brachytherapy |
Subjects: | |
Online Access: | http://www.termedia.pl/Physics-Contributions-Effect-of-using-different-U-S-probe-Standoff-materials-in-image-geometry-for-interventional-procedures-the-example-of-prostate,54,17926,1,1.html |
id |
doaj-3e5e00a4191d4b16ad4ba78b8076b028 |
---|---|
record_format |
Article |
spelling |
doaj-3e5e00a4191d4b16ad4ba78b8076b0282020-11-24T20:46:23ZengTermedia Publishing HouseJournal of Contemporary Brachytherapy1689-832X2081-28412011-12-0134209219Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostateDimos BaltasGeorge SakasPawel ZogalVasiliki KefalaZaira KatsilieriSaeed ButtNatasa MilickovicStefanos DiamantopoulosPurpose: This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostatebrachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation of currently established waterbathbased quality assurance (QA) procedures is presented. Material and methods: Image acquisitions of an ultrasound QA setup were carried out at 5 MHz and 7 MHz. The U/Sprobe was covered by EA 4015 Silicone Standoff kit, or UA0059 Endocavity balloon filled either with water or one ofthe following: 40 ml of Endosgel®, Instillagel®, Ultraschall gel or Space OAR™ gel. The differences between imageswere recorded. Consequently, the dosimetric impact of the observed image distortion was investigated, using a tissueequivalent ultrasound prostate phantom – Model number 053 (CIRS Inc., Norfolk, VA, USA). Results: By using the EA 4015 Silicone Standoff kit in normal water with sound speed of 1525 m/s, a 3 mm needleshift was observed. The expansion of objects appeared in radial direction. The shift deforms also the PTV (prostate inour case) and other organs at risk (OARs) in the same way leading to overestimation of volume and underestimationof the dose. On the other hand, Instillagel® and Space OAR™ “shrinks” objects in an ultrasound image for 0.65 mm and0.40 mm, respectively. Conclusions: The use of EA 4015 Silicone Standoff kit for image acquisition, leads to erroneous contouring of PTVand OARs and reconstruction and placement of catheters, which results to incorrect dose calculation during prostatebrachytherapy. Moreover, the reliability of QA procedures lies mostly in the right temperature of the water used foraccurate simulation of real conditions of transrectal ultrasound imaging.http://www.termedia.pl/Physics-Contributions-Effect-of-using-different-U-S-probe-Standoff-materials-in-image-geometry-for-interventional-procedures-the-example-of-prostate,54,17926,1,1.htmlultrasoundneedle displacementimage distortionprostate brachytherapy |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Dimos Baltas George Sakas Pawel Zogal Vasiliki Kefala Zaira Katsilieri Saeed Butt Natasa Milickovic Stefanos Diamantopoulos |
spellingShingle |
Dimos Baltas George Sakas Pawel Zogal Vasiliki Kefala Zaira Katsilieri Saeed Butt Natasa Milickovic Stefanos Diamantopoulos Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate Journal of Contemporary Brachytherapy ultrasound needle displacement image distortion prostate brachytherapy |
author_facet |
Dimos Baltas George Sakas Pawel Zogal Vasiliki Kefala Zaira Katsilieri Saeed Butt Natasa Milickovic Stefanos Diamantopoulos |
author_sort |
Dimos Baltas |
title |
Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate |
title_short |
Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate |
title_full |
Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate |
title_fullStr |
Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate |
title_full_unstemmed |
Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate |
title_sort |
effect of using different u/s probe standoff materials in image geometry for interventional procedures: the example of prostate |
publisher |
Termedia Publishing House |
series |
Journal of Contemporary Brachytherapy |
issn |
1689-832X 2081-2841 |
publishDate |
2011-12-01 |
description |
Purpose: This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostatebrachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation of currently established waterbathbased quality assurance (QA) procedures is presented. Material and methods: Image acquisitions of an ultrasound QA setup were carried out at 5 MHz and 7 MHz. The U/Sprobe was covered by EA 4015 Silicone Standoff kit, or UA0059 Endocavity balloon filled either with water or one ofthe following: 40 ml of Endosgel®, Instillagel®, Ultraschall gel or Space OAR™ gel. The differences between imageswere recorded. Consequently, the dosimetric impact of the observed image distortion was investigated, using a tissueequivalent ultrasound prostate phantom – Model number 053 (CIRS Inc., Norfolk, VA, USA). Results: By using the EA 4015 Silicone Standoff kit in normal water with sound speed of 1525 m/s, a 3 mm needleshift was observed. The expansion of objects appeared in radial direction. The shift deforms also the PTV (prostate inour case) and other organs at risk (OARs) in the same way leading to overestimation of volume and underestimationof the dose. On the other hand, Instillagel® and Space OAR™ “shrinks” objects in an ultrasound image for 0.65 mm and0.40 mm, respectively. Conclusions: The use of EA 4015 Silicone Standoff kit for image acquisition, leads to erroneous contouring of PTVand OARs and reconstruction and placement of catheters, which results to incorrect dose calculation during prostatebrachytherapy. Moreover, the reliability of QA procedures lies mostly in the right temperature of the water used foraccurate simulation of real conditions of transrectal ultrasound imaging. |
topic |
ultrasound needle displacement image distortion prostate brachytherapy |
url |
http://www.termedia.pl/Physics-Contributions-Effect-of-using-different-U-S-probe-Standoff-materials-in-image-geometry-for-interventional-procedures-the-example-of-prostate,54,17926,1,1.html |
work_keys_str_mv |
AT dimosbaltas effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate AT georgesakas effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate AT pawelzogal effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate AT vasilikikefala effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate AT zairakatsilieri effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate AT saeedbutt effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate AT natasamilickovic effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate AT stefanosdiamantopoulos effectofusingdifferentusprobestandoffmaterialsinimagegeometryforinterventionalprocedurestheexampleofprostate |
_version_ |
1716812826382696448 |