Comparison of Heat Recovery Ventilator Frost Control Techniques in the Canadian Arctic: Preheat and Recirculation

Air-to-air heat/energy recovery ventilators can effectively reduce the cost associated with ventilating a home. However, high indoor moisture levels, in conjunction with extreme temperature differences between the outdoor and indoor air can cause frost accumulation in the mechanical equipment, leadi...

Full description

Bibliographic Details
Main Authors: Berquist Justin, Banister Carsen, Pellissier Mathieu
Format: Article
Language:English
Published: EDP Sciences 2021-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/22/e3sconf_hvac2021_11010.pdf
id doaj-3df4952fd1b34a63aef69ef8d32469b6
record_format Article
spelling doaj-3df4952fd1b34a63aef69ef8d32469b62021-04-06T13:49:55ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012461101010.1051/e3sconf/202124611010e3sconf_hvac2021_11010Comparison of Heat Recovery Ventilator Frost Control Techniques in the Canadian Arctic: Preheat and RecirculationBerquist JustinBanister CarsenPellissier MathieuAir-to-air heat/energy recovery ventilators can effectively reduce the cost associated with ventilating a home. However, high indoor moisture levels, in conjunction with extreme temperature differences between the outdoor and indoor air can cause frost accumulation in the mechanical equipment, leading to performance degradation or failure. In this research, a demonstration house using a heat recovery ventilation system in Iqaluit, Nunavut, Canada was used to compare the performance of two frost control techniques: recirculation and electrical preheat. The advantages and disadvantages of each method are outlined to highlight the need to adapt southern strategies to ensure system functionality in the Arctic. The system was equipped with a heat recovery ventilator (HRV) with built-in recirculation technology to defrost the HRV, as well as two electric preheaters that can be used instead of recirculation and prevent frost formation. Between December 2018 and April 2019 the ventilation system’s performance was monitored for seven weeks while using either recirculation or electrical preheat. The experiments showed the ventilation system equipment consumed more absolute energy with electrical preheat than with recirculation as the frost control technique. However, when using recirculation, the ventilation system experienced more losses throughout the ventilation system, causing the whole building to consume more energy due to an increase in energy consumption by the home’s heating system. Moreover, the quantity of outdoor air that was restricted while using recirculation made electrical preheat the superior option for this ventilation system design. The energy use of the ventilation system with electric preheat enabled was 35% lower on a per volume of outdoor air basis. Contrary to some belief that preheating is a poor approach for frost control in heat/energy recovery ventilators, this research finds that preheating can be a more energy efficient method to provide ventilation if controlled well.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/22/e3sconf_hvac2021_11010.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Berquist Justin
Banister Carsen
Pellissier Mathieu
spellingShingle Berquist Justin
Banister Carsen
Pellissier Mathieu
Comparison of Heat Recovery Ventilator Frost Control Techniques in the Canadian Arctic: Preheat and Recirculation
E3S Web of Conferences
author_facet Berquist Justin
Banister Carsen
Pellissier Mathieu
author_sort Berquist Justin
title Comparison of Heat Recovery Ventilator Frost Control Techniques in the Canadian Arctic: Preheat and Recirculation
title_short Comparison of Heat Recovery Ventilator Frost Control Techniques in the Canadian Arctic: Preheat and Recirculation
title_full Comparison of Heat Recovery Ventilator Frost Control Techniques in the Canadian Arctic: Preheat and Recirculation
title_fullStr Comparison of Heat Recovery Ventilator Frost Control Techniques in the Canadian Arctic: Preheat and Recirculation
title_full_unstemmed Comparison of Heat Recovery Ventilator Frost Control Techniques in the Canadian Arctic: Preheat and Recirculation
title_sort comparison of heat recovery ventilator frost control techniques in the canadian arctic: preheat and recirculation
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2021-01-01
description Air-to-air heat/energy recovery ventilators can effectively reduce the cost associated with ventilating a home. However, high indoor moisture levels, in conjunction with extreme temperature differences between the outdoor and indoor air can cause frost accumulation in the mechanical equipment, leading to performance degradation or failure. In this research, a demonstration house using a heat recovery ventilation system in Iqaluit, Nunavut, Canada was used to compare the performance of two frost control techniques: recirculation and electrical preheat. The advantages and disadvantages of each method are outlined to highlight the need to adapt southern strategies to ensure system functionality in the Arctic. The system was equipped with a heat recovery ventilator (HRV) with built-in recirculation technology to defrost the HRV, as well as two electric preheaters that can be used instead of recirculation and prevent frost formation. Between December 2018 and April 2019 the ventilation system’s performance was monitored for seven weeks while using either recirculation or electrical preheat. The experiments showed the ventilation system equipment consumed more absolute energy with electrical preheat than with recirculation as the frost control technique. However, when using recirculation, the ventilation system experienced more losses throughout the ventilation system, causing the whole building to consume more energy due to an increase in energy consumption by the home’s heating system. Moreover, the quantity of outdoor air that was restricted while using recirculation made electrical preheat the superior option for this ventilation system design. The energy use of the ventilation system with electric preheat enabled was 35% lower on a per volume of outdoor air basis. Contrary to some belief that preheating is a poor approach for frost control in heat/energy recovery ventilators, this research finds that preheating can be a more energy efficient method to provide ventilation if controlled well.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/22/e3sconf_hvac2021_11010.pdf
work_keys_str_mv AT berquistjustin comparisonofheatrecoveryventilatorfrostcontroltechniquesinthecanadianarcticpreheatandrecirculation
AT banistercarsen comparisonofheatrecoveryventilatorfrostcontroltechniquesinthecanadianarcticpreheatandrecirculation
AT pellissiermathieu comparisonofheatrecoveryventilatorfrostcontroltechniquesinthecanadianarcticpreheatandrecirculation
_version_ 1721537872995024896