Automatic computerized measurement of retinal blood vessels with adaptive tracking algorithm and association with blood pressure

<p><strong>Background:</strong> To validate an automatic computer-based method for measuring the caliber of retinal blood vessels and use it to determine the effects of arterial hypertension on the calibers of these vessels and on their ratio.</p><p><strong>Method...

Full description

Bibliographic Details
Main Authors: Andrej Ikica, Uroš Prelesnik, Branko Ikica
Format: Article
Language:English
Published: Slovenian Medical Association 2007-05-01
Series:Zdravniški Vestnik
Subjects:
Online Access:http://vestnik.szd.si/index.php/ZdravVest/article/view/1733
id doaj-3d299620e36f4aadb50d1c578cca40d2
record_format Article
spelling doaj-3d299620e36f4aadb50d1c578cca40d22020-11-24T22:51:24ZengSlovenian Medical AssociationZdravniški Vestnik1318-03471581-02242007-05-017651246Automatic computerized measurement of retinal blood vessels with adaptive tracking algorithm and association with blood pressureAndrej IkicaUroš PrelesnikBranko Ikica<p><strong>Background:</strong> To validate an automatic computer-based method for measuring the caliber of retinal blood vessels and use it to determine the effects of arterial hypertension on the calibers of these vessels and on their ratio.</p><p><strong>Methods:</strong> 295 patients with increased blood pressure were analyzed. All arterioles and venules located in the area between one half and one disc diameter from the optic disc margin were measured with the computer based program. These measurements were combined to provide the average diameters of retinal arterioles and venules and the association with blood pressure was analyzed. The arteriole-to-venule ratio (AVR) was also calculated.</p><p><strong>Results:</strong> The average arteriolar diameter of patients who had hypertension from 5 to 15 years was 89.311 μm. Patients with hypertension for more than 15 years they had value of 79.276 μm. Average venular diameters were very similar in both groups (103.319 μm vs. 101.392 μm). We noticed differences in average arteriolar diameter between control group and hypertonic patients who had hypertension for more than 15 years (92.083 μm vs. 79.276 μm). Venular differences were minimal. The average of retinal venules in control group was 106.029 μm, in patients with hypertension for more than 15 years it was 101.392 μm.</p><p><strong>Conclusions:</strong> Using a computer-assisted method to measure retinal vessel diameter we found out that the diameter of retinal arterioles narrowed with blood pressure level. Our findings demonstrate a relation between presence and severity of hypertension and retinal diameter. Diameter of retinal venules hardly changed. Such relationship was similar with men and women. Fully automated system for analyzing retinal vessels is simple to use, quick and reliable.</p>http://vestnik.szd.si/index.php/ZdravVest/article/view/1733blood pressurefundus imagesautomatic measurement of retinal vessels diameter
collection DOAJ
language English
format Article
sources DOAJ
author Andrej Ikica
Uroš Prelesnik
Branko Ikica
spellingShingle Andrej Ikica
Uroš Prelesnik
Branko Ikica
Automatic computerized measurement of retinal blood vessels with adaptive tracking algorithm and association with blood pressure
Zdravniški Vestnik
blood pressure
fundus images
automatic measurement of retinal vessels diameter
author_facet Andrej Ikica
Uroš Prelesnik
Branko Ikica
author_sort Andrej Ikica
title Automatic computerized measurement of retinal blood vessels with adaptive tracking algorithm and association with blood pressure
title_short Automatic computerized measurement of retinal blood vessels with adaptive tracking algorithm and association with blood pressure
title_full Automatic computerized measurement of retinal blood vessels with adaptive tracking algorithm and association with blood pressure
title_fullStr Automatic computerized measurement of retinal blood vessels with adaptive tracking algorithm and association with blood pressure
title_full_unstemmed Automatic computerized measurement of retinal blood vessels with adaptive tracking algorithm and association with blood pressure
title_sort automatic computerized measurement of retinal blood vessels with adaptive tracking algorithm and association with blood pressure
publisher Slovenian Medical Association
series Zdravniški Vestnik
issn 1318-0347
1581-0224
publishDate 2007-05-01
description <p><strong>Background:</strong> To validate an automatic computer-based method for measuring the caliber of retinal blood vessels and use it to determine the effects of arterial hypertension on the calibers of these vessels and on their ratio.</p><p><strong>Methods:</strong> 295 patients with increased blood pressure were analyzed. All arterioles and venules located in the area between one half and one disc diameter from the optic disc margin were measured with the computer based program. These measurements were combined to provide the average diameters of retinal arterioles and venules and the association with blood pressure was analyzed. The arteriole-to-venule ratio (AVR) was also calculated.</p><p><strong>Results:</strong> The average arteriolar diameter of patients who had hypertension from 5 to 15 years was 89.311 μm. Patients with hypertension for more than 15 years they had value of 79.276 μm. Average venular diameters were very similar in both groups (103.319 μm vs. 101.392 μm). We noticed differences in average arteriolar diameter between control group and hypertonic patients who had hypertension for more than 15 years (92.083 μm vs. 79.276 μm). Venular differences were minimal. The average of retinal venules in control group was 106.029 μm, in patients with hypertension for more than 15 years it was 101.392 μm.</p><p><strong>Conclusions:</strong> Using a computer-assisted method to measure retinal vessel diameter we found out that the diameter of retinal arterioles narrowed with blood pressure level. Our findings demonstrate a relation between presence and severity of hypertension and retinal diameter. Diameter of retinal venules hardly changed. Such relationship was similar with men and women. Fully automated system for analyzing retinal vessels is simple to use, quick and reliable.</p>
topic blood pressure
fundus images
automatic measurement of retinal vessels diameter
url http://vestnik.szd.si/index.php/ZdravVest/article/view/1733
work_keys_str_mv AT andrejikica automaticcomputerizedmeasurementofretinalbloodvesselswithadaptivetrackingalgorithmandassociationwithbloodpressure
AT urosprelesnik automaticcomputerizedmeasurementofretinalbloodvesselswithadaptivetrackingalgorithmandassociationwithbloodpressure
AT brankoikica automaticcomputerizedmeasurementofretinalbloodvesselswithadaptivetrackingalgorithmandassociationwithbloodpressure
_version_ 1725669769003139072