Optimization of fall height setting for drop weight tested polypropylene
This study deals with polypropylene (PP) which was subjected the drop-weight test. PP is a semicrystalline thermoplastic polymer which is commonly used in many indoor applications and also in the automotive industry in the car interiors. The injection moulded PP samples were subjected the penetratio...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2017-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://doi.org/10.1051/matecconf/201712502049 |
id |
doaj-3cf0e9d05c8f4abc999d0bfb89da6f7e |
---|---|
record_format |
Article |
spelling |
doaj-3cf0e9d05c8f4abc999d0bfb89da6f7e2021-02-02T00:52:45ZengEDP SciencesMATEC Web of Conferences2261-236X2017-01-011250204910.1051/matecconf/201712502049matecconf_cscc2017_02049Optimization of fall height setting for drop weight tested polypropyleneHylova Lenka0Manas Miroslav1Tomas Bata University in ZlinTomas Bata University in ZlinThis study deals with polypropylene (PP) which was subjected the drop-weight test. PP is a semicrystalline thermoplastic polymer which is commonly used in many indoor applications and also in the automotive industry in the car interiors. The injection moulded PP samples were subjected the penetration test at different fall heights and the results were subsequently evaluated and discussed. It was found out that the fall heights from 100 to 230 J are suitable for PP penetration, but the optimal one is 100 J. Higher heights are not needed because of increasing power consumption of the test device.https://doi.org/10.1051/matecconf/201712502049 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Hylova Lenka Manas Miroslav |
spellingShingle |
Hylova Lenka Manas Miroslav Optimization of fall height setting for drop weight tested polypropylene MATEC Web of Conferences |
author_facet |
Hylova Lenka Manas Miroslav |
author_sort |
Hylova Lenka |
title |
Optimization of fall height setting for drop weight tested polypropylene |
title_short |
Optimization of fall height setting for drop weight tested polypropylene |
title_full |
Optimization of fall height setting for drop weight tested polypropylene |
title_fullStr |
Optimization of fall height setting for drop weight tested polypropylene |
title_full_unstemmed |
Optimization of fall height setting for drop weight tested polypropylene |
title_sort |
optimization of fall height setting for drop weight tested polypropylene |
publisher |
EDP Sciences |
series |
MATEC Web of Conferences |
issn |
2261-236X |
publishDate |
2017-01-01 |
description |
This study deals with polypropylene (PP) which was subjected the drop-weight test. PP is a semicrystalline thermoplastic polymer which is commonly used in many indoor applications and also in the automotive industry in the car interiors. The injection moulded PP samples were subjected the penetration test at different fall heights and the results were subsequently evaluated and discussed. It was found out that the fall heights from 100 to 230 J are suitable for PP penetration, but the optimal one is 100 J. Higher heights are not needed because of increasing power consumption of the test device. |
url |
https://doi.org/10.1051/matecconf/201712502049 |
work_keys_str_mv |
AT hylovalenka optimizationoffallheightsettingfordropweighttestedpolypropylene AT manasmiroslav optimizationoffallheightsettingfordropweighttestedpolypropylene |
_version_ |
1724312696589910016 |