Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-Up

Purpose. To evaluate long-term outcomes and complications of sutured scleral-fixated foldable intraocular lens (IOL) implantation. Design. Retrospective study. Methods. Patients who underwent sutured scleral-fixated foldable IOL implantation using 10-0 polypropylene suture were followed up for at le...

Full description

Bibliographic Details
Main Authors: Ting Yu, Mengting Yu, Wenjie Wu, Xinna Wu, Suzhen Xiao, Jialiang Mao, Yanling Wang
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2021/5525064
id doaj-3cdeca5ce9504d1594c5cbccdb861074
record_format Article
spelling doaj-3cdeca5ce9504d1594c5cbccdb8610742021-07-26T00:34:53ZengHindawi LimitedJournal of Ophthalmology2090-00582021-01-01202110.1155/2021/5525064Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-UpTing Yu0Mengting Yu1Wenjie Wu2Xinna Wu3Suzhen Xiao4Jialiang Mao5Yanling Wang6Ophthalmology DepartmentOphthalmology DepartmentOphthalmology DepartmentOphthalmology DepartmentOphthalmology DepartmentOphthalmology DepartmentOphthalmology DepartmentPurpose. To evaluate long-term outcomes and complications of sutured scleral-fixated foldable intraocular lens (IOL) implantation. Design. Retrospective study. Methods. Patients who underwent sutured scleral-fixated foldable IOL implantation using 10-0 polypropylene suture were followed up for at least 5 years at one Chinese tertiary hospital and two primary hospitals. Results. 52 eyes among 48 patients (35 male and 13 female) were evaluated. The mean age (years) was 50.27 ± 20.08 (range: 6 to 81). The mean postoperative follow-up time (months) was 79.70 ± 18.84 (range: 60 to 121). The mean best-corrected visual acuity (BCVA) improved from 0.83 ± 0.69 logarithm of the minimum angle of resolution (logMAR) at baseline to 0.50 ± 0.45 logMAR at the last follow-up visit. There was improved or unchanged BCVA in 44 eyes (84.62%) and reduced BCVA in 8 eyes (15.38%). Mild intraoperative intravitreal hemorrhage was observed in 3 eyes (5.77%). Early postoperative complications included transient elevated intraocular pressure (IOP) in 5 eyes (9.62%) and hypotony in 1 eye (1.92%). Secondary epimacular membrane occurred in 5 eyes (9.62%) and retinal detachment (RD; 3 years postsurgery), subconjunctival suture knot exposure (5 years postsurgery), and persistent elevated IOP (in a GRAVES patient) occurred in 1 eye (1.92%) each. No suture erosion or breakage nor IOL dislocation was observed. No visually threatening IOL tilt or decentration was reported in any patient. Conclusion. Sutured scleral-fixated foldable IOL implantation demonstrated satisfactory long-term outcomes and rare suture-related complications. This technology was safe and did not require complicated equipment and is of considerable interest in the setting of aphakia without adequate capsule support.http://dx.doi.org/10.1155/2021/5525064
collection DOAJ
language English
format Article
sources DOAJ
author Ting Yu
Mengting Yu
Wenjie Wu
Xinna Wu
Suzhen Xiao
Jialiang Mao
Yanling Wang
spellingShingle Ting Yu
Mengting Yu
Wenjie Wu
Xinna Wu
Suzhen Xiao
Jialiang Mao
Yanling Wang
Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-Up
Journal of Ophthalmology
author_facet Ting Yu
Mengting Yu
Wenjie Wu
Xinna Wu
Suzhen Xiao
Jialiang Mao
Yanling Wang
author_sort Ting Yu
title Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-Up
title_short Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-Up
title_full Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-Up
title_fullStr Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-Up
title_full_unstemmed Outcomes and Complications of Sutured Scleral-Fixated Foldable Intraocular Lens Implantation: A Retrospective Study of 5-Year Follow-Up
title_sort outcomes and complications of sutured scleral-fixated foldable intraocular lens implantation: a retrospective study of 5-year follow-up
publisher Hindawi Limited
series Journal of Ophthalmology
issn 2090-0058
publishDate 2021-01-01
description Purpose. To evaluate long-term outcomes and complications of sutured scleral-fixated foldable intraocular lens (IOL) implantation. Design. Retrospective study. Methods. Patients who underwent sutured scleral-fixated foldable IOL implantation using 10-0 polypropylene suture were followed up for at least 5 years at one Chinese tertiary hospital and two primary hospitals. Results. 52 eyes among 48 patients (35 male and 13 female) were evaluated. The mean age (years) was 50.27 ± 20.08 (range: 6 to 81). The mean postoperative follow-up time (months) was 79.70 ± 18.84 (range: 60 to 121). The mean best-corrected visual acuity (BCVA) improved from 0.83 ± 0.69 logarithm of the minimum angle of resolution (logMAR) at baseline to 0.50 ± 0.45 logMAR at the last follow-up visit. There was improved or unchanged BCVA in 44 eyes (84.62%) and reduced BCVA in 8 eyes (15.38%). Mild intraoperative intravitreal hemorrhage was observed in 3 eyes (5.77%). Early postoperative complications included transient elevated intraocular pressure (IOP) in 5 eyes (9.62%) and hypotony in 1 eye (1.92%). Secondary epimacular membrane occurred in 5 eyes (9.62%) and retinal detachment (RD; 3 years postsurgery), subconjunctival suture knot exposure (5 years postsurgery), and persistent elevated IOP (in a GRAVES patient) occurred in 1 eye (1.92%) each. No suture erosion or breakage nor IOL dislocation was observed. No visually threatening IOL tilt or decentration was reported in any patient. Conclusion. Sutured scleral-fixated foldable IOL implantation demonstrated satisfactory long-term outcomes and rare suture-related complications. This technology was safe and did not require complicated equipment and is of considerable interest in the setting of aphakia without adequate capsule support.
url http://dx.doi.org/10.1155/2021/5525064
work_keys_str_mv AT tingyu outcomesandcomplicationsofsuturedscleralfixatedfoldableintraocularlensimplantationaretrospectivestudyof5yearfollowup
AT mengtingyu outcomesandcomplicationsofsuturedscleralfixatedfoldableintraocularlensimplantationaretrospectivestudyof5yearfollowup
AT wenjiewu outcomesandcomplicationsofsuturedscleralfixatedfoldableintraocularlensimplantationaretrospectivestudyof5yearfollowup
AT xinnawu outcomesandcomplicationsofsuturedscleralfixatedfoldableintraocularlensimplantationaretrospectivestudyof5yearfollowup
AT suzhenxiao outcomesandcomplicationsofsuturedscleralfixatedfoldableintraocularlensimplantationaretrospectivestudyof5yearfollowup
AT jialiangmao outcomesandcomplicationsofsuturedscleralfixatedfoldableintraocularlensimplantationaretrospectivestudyof5yearfollowup
AT yanlingwang outcomesandcomplicationsofsuturedscleralfixatedfoldableintraocularlensimplantationaretrospectivestudyof5yearfollowup
_version_ 1721282300222636032