Comparison of automatic airway analysis function of Invivo5 and Romexis software

Background Visualization and calculation of the airway dimensions are important because an increase of airway resistance may lead to life-threatening emergencies. The visualization and calculation of the airway are possible using radiography technique with their advance software. The aim of this stu...

Full description

Bibliographic Details
Main Authors: Noorshaida Kamaruddin, Firdaus Daud, Asilah Yusof, Mohd Ezane Aziz, Zainul A. Rajion
Format: Article
Language:English
Published: PeerJ Inc. 2019-01-01
Series:PeerJ
Subjects:
Online Access:https://peerj.com/articles/6319.pdf
id doaj-3cd074ea480d4038a6c9f0f492ae654e
record_format Article
spelling doaj-3cd074ea480d4038a6c9f0f492ae654e2020-11-24T21:47:59ZengPeerJ Inc.PeerJ2167-83592019-01-017e631910.7717/peerj.6319Comparison of automatic airway analysis function of Invivo5 and Romexis softwareNoorshaida Kamaruddin0Firdaus Daud1Asilah Yusof2Mohd Ezane Aziz3Zainul A. Rajion4School of Dental Sciences, Universiti Sains Malaysia, Health Campus, Kota Bharu, Kelantan, MalaysiaSchool of Dental Sciences, Universiti Sains Malaysia, Health Campus, Kota Bharu, Kelantan, MalaysiaSchool of Dental Sciences, Universiti Sains Malaysia, Health Campus, Kota Bharu, Kelantan, MalaysiaSchool of Medical Sciences, Universiti Sains Malaysia Health Campus, Kota Bharu, Kelantan, MalaysiaSchool of Dental Sciences, Universiti Sains Malaysia, Health Campus, Kota Bharu, Kelantan, MalaysiaBackground Visualization and calculation of the airway dimensions are important because an increase of airway resistance may lead to life-threatening emergencies. The visualization and calculation of the airway are possible using radiography technique with their advance software. The aim of this study was to compare and to test the reliability of the measurement of the upper airway volume and minimum area using airway analysis function in two software. Methods The sample consisted of 11 cone-beam computed tomography (CBCT) scans data, evaluated using the Invivo5 (Anatomage) and Romexis (version 3.8.2.R, Planmeca) software which afford image reconstruction, and airway analysis. The measurements were done twice with one week gap between the two measurements. The measurement obtained was analyzed with t-tests and intraclass correlation coefficient (ICC), with confidence intervals (CI) was set at 95%. Results From the analysis, the mean reading of volume and minimum area is not significantly different between Invivo5 and Romexis. Excellent intrarater reliability values were found for the both measurement on both software, with ICC values ranging from 0.940 to 0.998. Discussion The results suggested that both software can be used in further studies to investigate upper airway, thereby contributing to the diagnosis of upper airway obstructions.https://peerj.com/articles/6319.pdfCone-beam computed tomographyAutomatic airway analysisAirway volumeMinimum area
collection DOAJ
language English
format Article
sources DOAJ
author Noorshaida Kamaruddin
Firdaus Daud
Asilah Yusof
Mohd Ezane Aziz
Zainul A. Rajion
spellingShingle Noorshaida Kamaruddin
Firdaus Daud
Asilah Yusof
Mohd Ezane Aziz
Zainul A. Rajion
Comparison of automatic airway analysis function of Invivo5 and Romexis software
PeerJ
Cone-beam computed tomography
Automatic airway analysis
Airway volume
Minimum area
author_facet Noorshaida Kamaruddin
Firdaus Daud
Asilah Yusof
Mohd Ezane Aziz
Zainul A. Rajion
author_sort Noorshaida Kamaruddin
title Comparison of automatic airway analysis function of Invivo5 and Romexis software
title_short Comparison of automatic airway analysis function of Invivo5 and Romexis software
title_full Comparison of automatic airway analysis function of Invivo5 and Romexis software
title_fullStr Comparison of automatic airway analysis function of Invivo5 and Romexis software
title_full_unstemmed Comparison of automatic airway analysis function of Invivo5 and Romexis software
title_sort comparison of automatic airway analysis function of invivo5 and romexis software
publisher PeerJ Inc.
series PeerJ
issn 2167-8359
publishDate 2019-01-01
description Background Visualization and calculation of the airway dimensions are important because an increase of airway resistance may lead to life-threatening emergencies. The visualization and calculation of the airway are possible using radiography technique with their advance software. The aim of this study was to compare and to test the reliability of the measurement of the upper airway volume and minimum area using airway analysis function in two software. Methods The sample consisted of 11 cone-beam computed tomography (CBCT) scans data, evaluated using the Invivo5 (Anatomage) and Romexis (version 3.8.2.R, Planmeca) software which afford image reconstruction, and airway analysis. The measurements were done twice with one week gap between the two measurements. The measurement obtained was analyzed with t-tests and intraclass correlation coefficient (ICC), with confidence intervals (CI) was set at 95%. Results From the analysis, the mean reading of volume and minimum area is not significantly different between Invivo5 and Romexis. Excellent intrarater reliability values were found for the both measurement on both software, with ICC values ranging from 0.940 to 0.998. Discussion The results suggested that both software can be used in further studies to investigate upper airway, thereby contributing to the diagnosis of upper airway obstructions.
topic Cone-beam computed tomography
Automatic airway analysis
Airway volume
Minimum area
url https://peerj.com/articles/6319.pdf
work_keys_str_mv AT noorshaidakamaruddin comparisonofautomaticairwayanalysisfunctionofinvivo5andromexissoftware
AT firdausdaud comparisonofautomaticairwayanalysisfunctionofinvivo5andromexissoftware
AT asilahyusof comparisonofautomaticairwayanalysisfunctionofinvivo5andromexissoftware
AT mohdezaneaziz comparisonofautomaticairwayanalysisfunctionofinvivo5andromexissoftware
AT zainularajion comparisonofautomaticairwayanalysisfunctionofinvivo5andromexissoftware
_version_ 1725894215726006272