Filtering the phase voltages of the frequency converter in the identification of the parameters of three-phase asynchronous motor

The expediency of application of active filters Butterworth third order to highlight the basic harmonic of the phase voltages of a two-level frequency converter in the identification of the parameters of three-phase asynchronous motor is shown. For the implementation of the identification algorithm...

Full description

Bibliographic Details
Main Authors: A. J. Afanasiev, V. G. Makarov, Y. A. Yakovlev, V. N. Khannanova
Format: Article
Language:English
Published: Kazan State Power Engineering University 2017-12-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/142
id doaj-3c639558960e45c6a44cc65745fa7735
record_format Article
spelling doaj-3c639558960e45c6a44cc65745fa77352021-07-28T13:16:28ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032017-12-0109-10526210.30724/1998-9903-2015-0-9-10-52-62142Filtering the phase voltages of the frequency converter in the identification of the parameters of three-phase asynchronous motorA. J. Afanasiev0V. G. Makarov1Y. A. Yakovlev2V. N. Khannanova3Казанский национальный исследовательский технический университет им. А.Н. ТуполеваКазанский национальный исследовательский технологический университетКазанский национальный исследовательский технологический университетКазанский национальный исследовательский технологический университетThe expediency of application of active filters Butterworth third order to highlight the basic harmonic of the phase voltages of a two-level frequency converter in the identification of the parameters of three-phase asynchronous motor is shown. For the implementation of the identification algorithm it is necessary to convert the output voltages of the filters in the voltage phases of the stator winding of the generalized electric machine. It is experimentally determined that the presence offilters low frequency does not introduce significant distortion and allows to obtain the necessary shape of the phase voltages of the generalized electric machine.https://www.energyret.ru/jour/article/view/142identification of parametersgeneralised electric machinecoordinate transformationfrequency converterasynchronous three-phase motorthe butterworth filterpulse width modulation
collection DOAJ
language English
format Article
sources DOAJ
author A. J. Afanasiev
V. G. Makarov
Y. A. Yakovlev
V. N. Khannanova
spellingShingle A. J. Afanasiev
V. G. Makarov
Y. A. Yakovlev
V. N. Khannanova
Filtering the phase voltages of the frequency converter in the identification of the parameters of three-phase asynchronous motor
Известия высших учебных заведений: Проблемы энергетики
identification of parameters
generalised electric machine
coordinate transformation
frequency converter
asynchronous three-phase motor
the butterworth filter
pulse width modulation
author_facet A. J. Afanasiev
V. G. Makarov
Y. A. Yakovlev
V. N. Khannanova
author_sort A. J. Afanasiev
title Filtering the phase voltages of the frequency converter in the identification of the parameters of three-phase asynchronous motor
title_short Filtering the phase voltages of the frequency converter in the identification of the parameters of three-phase asynchronous motor
title_full Filtering the phase voltages of the frequency converter in the identification of the parameters of three-phase asynchronous motor
title_fullStr Filtering the phase voltages of the frequency converter in the identification of the parameters of three-phase asynchronous motor
title_full_unstemmed Filtering the phase voltages of the frequency converter in the identification of the parameters of three-phase asynchronous motor
title_sort filtering the phase voltages of the frequency converter in the identification of the parameters of three-phase asynchronous motor
publisher Kazan State Power Engineering University
series Известия высших учебных заведений: Проблемы энергетики
issn 1998-9903
publishDate 2017-12-01
description The expediency of application of active filters Butterworth third order to highlight the basic harmonic of the phase voltages of a two-level frequency converter in the identification of the parameters of three-phase asynchronous motor is shown. For the implementation of the identification algorithm it is necessary to convert the output voltages of the filters in the voltage phases of the stator winding of the generalized electric machine. It is experimentally determined that the presence offilters low frequency does not introduce significant distortion and allows to obtain the necessary shape of the phase voltages of the generalized electric machine.
topic identification of parameters
generalised electric machine
coordinate transformation
frequency converter
asynchronous three-phase motor
the butterworth filter
pulse width modulation
url https://www.energyret.ru/jour/article/view/142
work_keys_str_mv AT ajafanasiev filteringthephasevoltagesofthefrequencyconverterintheidentificationoftheparametersofthreephaseasynchronousmotor
AT vgmakarov filteringthephasevoltagesofthefrequencyconverterintheidentificationoftheparametersofthreephaseasynchronousmotor
AT yayakovlev filteringthephasevoltagesofthefrequencyconverterintheidentificationoftheparametersofthreephaseasynchronousmotor
AT vnkhannanova filteringthephasevoltagesofthefrequencyconverterintheidentificationoftheparametersofthreephaseasynchronousmotor
_version_ 1721275837365354496