Determination of Type and Concentration of Electrolyte Solution on the Basis of Analysis of Potentiodynamic Curves

The paper shows the results of experimental investigation of non-stable regimes of excitation of electrode system of conductivity measuring cell. The analysis of experimental data based on existing theory of electrode processes has been made. The interpretation of non-conventional results concerning...

Full description

Bibliographic Details
Main Authors: R. I. Vorobey, O. K. Gusev, V. P. Kiryeenko, A. K. Tyavlovsky, K. L. Tyavlovsky, V. B. Yarzhembitsky
Format: Article
Language:Russian
Published: Belarusian National Technical University 2003-04-01
Series:Nauka i Tehnika
Online Access:https://sat.bntu.by/jour/article/view/1594
id doaj-3c5a7b2ac0874068ab97c551134d8c7c
record_format Article
spelling doaj-3c5a7b2ac0874068ab97c551134d8c7c2021-07-29T08:29:21ZrusBelarusian National Technical UniversityNauka i Tehnika2227-10312414-03922003-04-0102485310.21122/2227-1031-2003-0-2-48-531494Determination of Type and Concentration of Electrolyte Solution on the Basis of Analysis of Potentiodynamic CurvesR. I. Vorobey0O. K. Gusev1V. P. Kiryeenko2A. K. Tyavlovsky3K. L. Tyavlovsky4V. B. Yarzhembitsky5Belarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityThe paper shows the results of experimental investigation of non-stable regimes of excitation of electrode system of conductivity measuring cell. The analysis of experimental data based on existing theory of electrode processes has been made. The interpretation of non-conventional results concerning the dependence of conductivity measuring cell current on voltage excitation has been given. It has been shown that with certain parameters of excitation potentiodynamic curves significantly differ for various types of solutions (in particular for acid and alkali media) that makes it possible to use the regime of analysis of these curves for determination of type and concentration of a solution. Operational diagram of the device using the detected effect is given in the paper.https://sat.bntu.by/jour/article/view/1594
collection DOAJ
language Russian
format Article
sources DOAJ
author R. I. Vorobey
O. K. Gusev
V. P. Kiryeenko
A. K. Tyavlovsky
K. L. Tyavlovsky
V. B. Yarzhembitsky
spellingShingle R. I. Vorobey
O. K. Gusev
V. P. Kiryeenko
A. K. Tyavlovsky
K. L. Tyavlovsky
V. B. Yarzhembitsky
Determination of Type and Concentration of Electrolyte Solution on the Basis of Analysis of Potentiodynamic Curves
Nauka i Tehnika
author_facet R. I. Vorobey
O. K. Gusev
V. P. Kiryeenko
A. K. Tyavlovsky
K. L. Tyavlovsky
V. B. Yarzhembitsky
author_sort R. I. Vorobey
title Determination of Type and Concentration of Electrolyte Solution on the Basis of Analysis of Potentiodynamic Curves
title_short Determination of Type and Concentration of Electrolyte Solution on the Basis of Analysis of Potentiodynamic Curves
title_full Determination of Type and Concentration of Electrolyte Solution on the Basis of Analysis of Potentiodynamic Curves
title_fullStr Determination of Type and Concentration of Electrolyte Solution on the Basis of Analysis of Potentiodynamic Curves
title_full_unstemmed Determination of Type and Concentration of Electrolyte Solution on the Basis of Analysis of Potentiodynamic Curves
title_sort determination of type and concentration of electrolyte solution on the basis of analysis of potentiodynamic curves
publisher Belarusian National Technical University
series Nauka i Tehnika
issn 2227-1031
2414-0392
publishDate 2003-04-01
description The paper shows the results of experimental investigation of non-stable regimes of excitation of electrode system of conductivity measuring cell. The analysis of experimental data based on existing theory of electrode processes has been made. The interpretation of non-conventional results concerning the dependence of conductivity measuring cell current on voltage excitation has been given. It has been shown that with certain parameters of excitation potentiodynamic curves significantly differ for various types of solutions (in particular for acid and alkali media) that makes it possible to use the regime of analysis of these curves for determination of type and concentration of a solution. Operational diagram of the device using the detected effect is given in the paper.
url https://sat.bntu.by/jour/article/view/1594
work_keys_str_mv AT rivorobey determinationoftypeandconcentrationofelectrolytesolutiononthebasisofanalysisofpotentiodynamiccurves
AT okgusev determinationoftypeandconcentrationofelectrolytesolutiononthebasisofanalysisofpotentiodynamiccurves
AT vpkiryeenko determinationoftypeandconcentrationofelectrolytesolutiononthebasisofanalysisofpotentiodynamiccurves
AT aktyavlovsky determinationoftypeandconcentrationofelectrolytesolutiononthebasisofanalysisofpotentiodynamiccurves
AT kltyavlovsky determinationoftypeandconcentrationofelectrolytesolutiononthebasisofanalysisofpotentiodynamiccurves
AT vbyarzhembitsky determinationoftypeandconcentrationofelectrolytesolutiononthebasisofanalysisofpotentiodynamiccurves
_version_ 1721255976675311616