Simultaneous estimation of silodosin and silodosin β-D-glucuronide in human plasma using LC-MS/MS for a pharmacokinetic study
A rapid, simple, sensitive and selective LC-MS/MS method has been developed and validated for simultaneous quantification of silodosin and silodosin β-D-glucuronide human plasma using stable labelled isotopes as internal standards. Solid phase extraction technique (SPE) was used for the extraction a...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Taylor & Francis Group
2018-07-01
|
Series: | Journal of Taibah University for Science |
Subjects: | |
Online Access: | http://dx.doi.org/10.1080/16583655.2018.1490562 |
id |
doaj-3be6288313e6464ca5494fce2aa35a97 |
---|---|
record_format |
Article |
spelling |
doaj-3be6288313e6464ca5494fce2aa35a972020-11-25T00:56:45ZengTaylor & Francis GroupJournal of Taibah University for Science1658-36552018-07-0112439340010.1080/16583655.2018.14905621490562Simultaneous estimation of silodosin and silodosin β-D-glucuronide in human plasma using LC-MS/MS for a pharmacokinetic studySiva Sankara Rao Yadlapalli0Naresh Kumar Katari1Surendra Babu Manabolu2Vasu Babu Ravi3GITAM UniversityGITAM UniversityGITAM UniversityAnaCipher Clinical Research OrganizationA rapid, simple, sensitive and selective LC-MS/MS method has been developed and validated for simultaneous quantification of silodosin and silodosin β-D-glucuronide human plasma using stable labelled isotopes as internal standards. Solid phase extraction technique (SPE) was used for the extraction and the method validated over a range of 0.20 ng/mL to 100.56 ng/mL for silidisin and 0.20 ng/mL to 101.63 ng/mL for silodosin β-D-glucuronide. The chromatographic separation was achieved on Cosmicsil Adze C18 (4.6 × 100 mm, 3 µm) column using a mobile phase consisting of acetonitrile, methanol and 10 mM ammonium acetate buffer 50:20:30 (v/v/v) at a flow rate of 1.000 mL/min with run time of 4 min. The API-4500 LC-MS/MS was operated under the multiple-reaction monitoring mode using electrospray ionization. The developed assay method was successfully applied to a pharmacokinetic study in humans.http://dx.doi.org/10.1080/16583655.2018.1490562Silodosinsilodosin β-D-glucuronidehuman plasmaLC–MS/MSmethod developmentpharmacokineticsquantification |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Siva Sankara Rao Yadlapalli Naresh Kumar Katari Surendra Babu Manabolu Vasu Babu Ravi |
spellingShingle |
Siva Sankara Rao Yadlapalli Naresh Kumar Katari Surendra Babu Manabolu Vasu Babu Ravi Simultaneous estimation of silodosin and silodosin β-D-glucuronide in human plasma using LC-MS/MS for a pharmacokinetic study Journal of Taibah University for Science Silodosin silodosin β-D-glucuronide human plasma LC–MS/MS method development pharmacokinetics quantification |
author_facet |
Siva Sankara Rao Yadlapalli Naresh Kumar Katari Surendra Babu Manabolu Vasu Babu Ravi |
author_sort |
Siva Sankara Rao Yadlapalli |
title |
Simultaneous estimation of silodosin and silodosin β-D-glucuronide in human plasma using LC-MS/MS for a pharmacokinetic study |
title_short |
Simultaneous estimation of silodosin and silodosin β-D-glucuronide in human plasma using LC-MS/MS for a pharmacokinetic study |
title_full |
Simultaneous estimation of silodosin and silodosin β-D-glucuronide in human plasma using LC-MS/MS for a pharmacokinetic study |
title_fullStr |
Simultaneous estimation of silodosin and silodosin β-D-glucuronide in human plasma using LC-MS/MS for a pharmacokinetic study |
title_full_unstemmed |
Simultaneous estimation of silodosin and silodosin β-D-glucuronide in human plasma using LC-MS/MS for a pharmacokinetic study |
title_sort |
simultaneous estimation of silodosin and silodosin β-d-glucuronide in human plasma using lc-ms/ms for a pharmacokinetic study |
publisher |
Taylor & Francis Group |
series |
Journal of Taibah University for Science |
issn |
1658-3655 |
publishDate |
2018-07-01 |
description |
A rapid, simple, sensitive and selective LC-MS/MS method has been developed and validated for simultaneous quantification of silodosin and silodosin β-D-glucuronide human plasma using stable labelled isotopes as internal standards. Solid phase extraction technique (SPE) was used for the extraction and the method validated over a range of 0.20 ng/mL to 100.56 ng/mL for silidisin and 0.20 ng/mL to 101.63 ng/mL for silodosin β-D-glucuronide. The chromatographic separation was achieved on Cosmicsil Adze C18 (4.6 × 100 mm, 3 µm) column using a mobile phase consisting of acetonitrile, methanol and 10 mM ammonium acetate buffer 50:20:30 (v/v/v) at a flow rate of 1.000 mL/min with run time of 4 min. The API-4500 LC-MS/MS was operated under the multiple-reaction monitoring mode using electrospray ionization. The developed assay method was successfully applied to a pharmacokinetic study in humans. |
topic |
Silodosin silodosin β-D-glucuronide human plasma LC–MS/MS method development pharmacokinetics quantification |
url |
http://dx.doi.org/10.1080/16583655.2018.1490562 |
work_keys_str_mv |
AT sivasankararaoyadlapalli simultaneousestimationofsilodosinandsilodosinbdglucuronideinhumanplasmausinglcmsmsforapharmacokineticstudy AT nareshkumarkatari simultaneousestimationofsilodosinandsilodosinbdglucuronideinhumanplasmausinglcmsmsforapharmacokineticstudy AT surendrababumanabolu simultaneousestimationofsilodosinandsilodosinbdglucuronideinhumanplasmausinglcmsmsforapharmacokineticstudy AT vasubaburavi simultaneousestimationofsilodosinandsilodosinbdglucuronideinhumanplasmausinglcmsmsforapharmacokineticstudy |
_version_ |
1725225663360663552 |