Results of an intercomparison for free space antenna factor measurements within the German Calibration Service (DKD)
In this paper we discuss the results of an intercomparison for free space antenna factor measurements performed within the German Calibration Service (DKD). Three different types of antennas covering the frequency range from 30 MHz to 26.5 GHz have been calibrated in five different laboratories usin...
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Language: | deu |
Published: |
Copernicus Publications
2016-09-01
|
Series: | Advances in Radio Science |
Online Access: | http://www.adv-radio-sci.net/14/11/2016/ars-14-11-2016.pdf |
id |
doaj-3b417a34ae5b423c844fec44205e7dff |
---|---|
record_format |
Article |
spelling |
doaj-3b417a34ae5b423c844fec44205e7dff2020-11-25T00:07:04ZdeuCopernicus PublicationsAdvances in Radio Science 1684-99651684-99732016-09-0114111610.5194/ars-14-11-2016Results of an intercomparison for free space antenna factor measurements within the German Calibration Service (DKD)T. Kleine-Ostmann0F. Huncke1D. Schwarzbeck2O. Martetschläger3J. Gaßner4A. Guserle5C. Römer6T. Hufnagel7M. Lehmann8U. Karsten9T. Schrader10Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, GermanyOberingenieur Berg & Lukowiak GmbH, Löhner Str. 157, 32609 Hüllhorst, GermanySchwarzbeck Messelektronik OHG, An der Klinge 29, 69250 Schönau, GermanyRohde & Schwarz Messgerätebau GmbH, Rohde-und-Schwarz-Str. 1, 87700 Memmingen, GermanyRohde & Schwarz Messgerätebau GmbH, Rohde-und-Schwarz-Str. 1, 87700 Memmingen, GermanyRohde & Schwarz Messgerätebau GmbH, Rohde-und-Schwarz-Str. 1, 87700 Memmingen, GermanyBureau Veritas CPS Germany GmbH, Thurn-und Taxis-Str. 18, 90411 Nürnberg, GermanyBureau Veritas CPS Germany GmbH, Thurn-und Taxis-Str. 18, 90411 Nürnberg, GermanyBureau Veritas CPS Germany GmbH, Thurn-und Taxis-Str. 18, 90411 Nürnberg, GermanyTESEQ GmbH, Landsberger Str. 255, 12623 Berlin, GermanyPhysikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, GermanyIn this paper we discuss the results of an intercomparison for free space antenna factor measurements performed within the German Calibration Service (DKD). Three different types of antennas covering the frequency range from 30 MHz to 26.5 GHz have been calibrated in five different laboratories using different methods and calibration sites to obtain the free space antenna factor. The results agree well within the uncertainties specified by the laboratories suggesting that different approaches and different measurement sites to obtain the free space antenna factor are well compatible.http://www.adv-radio-sci.net/14/11/2016/ars-14-11-2016.pdf |
collection |
DOAJ |
language |
deu |
format |
Article |
sources |
DOAJ |
author |
T. Kleine-Ostmann F. Huncke D. Schwarzbeck O. Martetschläger J. Gaßner A. Guserle C. Römer T. Hufnagel M. Lehmann U. Karsten T. Schrader |
spellingShingle |
T. Kleine-Ostmann F. Huncke D. Schwarzbeck O. Martetschläger J. Gaßner A. Guserle C. Römer T. Hufnagel M. Lehmann U. Karsten T. Schrader Results of an intercomparison for free space antenna factor measurements within the German Calibration Service (DKD) Advances in Radio Science |
author_facet |
T. Kleine-Ostmann F. Huncke D. Schwarzbeck O. Martetschläger J. Gaßner A. Guserle C. Römer T. Hufnagel M. Lehmann U. Karsten T. Schrader |
author_sort |
T. Kleine-Ostmann |
title |
Results of an intercomparison for free space antenna factor measurements
within the German Calibration Service (DKD) |
title_short |
Results of an intercomparison for free space antenna factor measurements
within the German Calibration Service (DKD) |
title_full |
Results of an intercomparison for free space antenna factor measurements
within the German Calibration Service (DKD) |
title_fullStr |
Results of an intercomparison for free space antenna factor measurements
within the German Calibration Service (DKD) |
title_full_unstemmed |
Results of an intercomparison for free space antenna factor measurements
within the German Calibration Service (DKD) |
title_sort |
results of an intercomparison for free space antenna factor measurements
within the german calibration service (dkd) |
publisher |
Copernicus Publications |
series |
Advances in Radio Science |
issn |
1684-9965 1684-9973 |
publishDate |
2016-09-01 |
description |
In this paper we discuss the results of an intercomparison for free space
antenna factor measurements performed within the German Calibration Service
(DKD). Three different types of antennas covering the frequency range from
30 MHz to 26.5 GHz have been calibrated in five different laboratories using
different methods and calibration sites to obtain the free space antenna
factor. The results agree well within the uncertainties specified by the
laboratories suggesting that different approaches and different measurement
sites to obtain the free space antenna factor are well compatible. |
url |
http://www.adv-radio-sci.net/14/11/2016/ars-14-11-2016.pdf |
work_keys_str_mv |
AT tkleineostmann resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd AT fhuncke resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd AT dschwarzbeck resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd AT omartetschlager resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd AT jgaßner resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd AT aguserle resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd AT cromer resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd AT thufnagel resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd AT mlehmann resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd AT ukarsten resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd AT tschrader resultsofanintercomparisonforfreespaceantennafactormeasurementswithinthegermancalibrationservicedkd |