Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status
Cochlear implants (CI) are the treatment of choice in profoundly deaf patients. Measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the function of the spiral ganglion neurons (SGN), which are the target cells of the CI stimulation. ECAP meas...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-03-01
|
Series: | Life |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-1729/11/3/203 |
id |
doaj-3b131865d0074c25be955f8447603144 |
---|---|
record_format |
Article |
spelling |
doaj-3b131865d0074c25be955f84476031442021-03-06T00:03:06ZengMDPI AGLife2075-17292021-03-011120320310.3390/life11030203Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health StatusLutz Gärtner0Katharina Klötzer1Thomas Lenarz2Verena Scheper3Department of Otolaryngology, Hannover Medical School, 30625 Hannover, GermanyDepartment of Otolaryngology, Hannover Medical School, 30625 Hannover, GermanyDepartment of Otolaryngology, Hannover Medical School, 30625 Hannover, GermanyDepartment of Otolaryngology, Hannover Medical School, 30625 Hannover, GermanyCochlear implants (CI) are the treatment of choice in profoundly deaf patients. Measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the function of the spiral ganglion neurons (SGN), which are the target cells of the CI stimulation. ECAP measurement is only possible after electrode insertion. No information about the neuronal health status is available before cochlear implantation. We investigated possible correlations between the ECAP amplitude growth function (AGF) slope and anamnestic parameters to identify possible predictors for SGN health status and therefore for CI outcome. The study included patients being implanted with various electrode array lengths. Correlation analysis was performed for the mean AGF slope of the whole array, for separate electrodes as well as for grouped electrodes of the apical, medial, and basal region, with duration of deafness, age at implantation, residual hearing (grouped for electrode length), and etiology. The mean ECAP AGF slopes decreased from apical to basal. They were not correlated to the length of the electrode array or any etiology. For the mean of the full array or when grouped for the apical, middle, and basal part, the ECAP AGF slope was negatively correlated to the duration of hearing loss and the age at implantation. Since a significant negative correlation of the ECAP AGF slope and age at cochlear implantation and duration of deafness was observed, this study supports the statement that early implantation of a CI is recommended for sensorineural hearing loss. Additional factors such as the cochlear coverage and insertion angle influence the ECAP AGF slope and performance of the patient and should be included in future multifactorial analysis to study predictive parameters for the CI outcome.https://www.mdpi.com/2075-1729/11/3/203ECAP AGF slopeprognostic factorsneuronal functionspiral ganglion neurons |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Lutz Gärtner Katharina Klötzer Thomas Lenarz Verena Scheper |
spellingShingle |
Lutz Gärtner Katharina Klötzer Thomas Lenarz Verena Scheper Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status Life ECAP AGF slope prognostic factors neuronal function spiral ganglion neurons |
author_facet |
Lutz Gärtner Katharina Klötzer Thomas Lenarz Verena Scheper |
author_sort |
Lutz Gärtner |
title |
Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status |
title_short |
Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status |
title_full |
Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status |
title_fullStr |
Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status |
title_full_unstemmed |
Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status |
title_sort |
correlation of electrically evoked compound action potential amplitude growth function slope and anamnestic parameters in cochlear implant patients—identification of predictors for the neuronal health status |
publisher |
MDPI AG |
series |
Life |
issn |
2075-1729 |
publishDate |
2021-03-01 |
description |
Cochlear implants (CI) are the treatment of choice in profoundly deaf patients. Measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the function of the spiral ganglion neurons (SGN), which are the target cells of the CI stimulation. ECAP measurement is only possible after electrode insertion. No information about the neuronal health status is available before cochlear implantation. We investigated possible correlations between the ECAP amplitude growth function (AGF) slope and anamnestic parameters to identify possible predictors for SGN health status and therefore for CI outcome. The study included patients being implanted with various electrode array lengths. Correlation analysis was performed for the mean AGF slope of the whole array, for separate electrodes as well as for grouped electrodes of the apical, medial, and basal region, with duration of deafness, age at implantation, residual hearing (grouped for electrode length), and etiology. The mean ECAP AGF slopes decreased from apical to basal. They were not correlated to the length of the electrode array or any etiology. For the mean of the full array or when grouped for the apical, middle, and basal part, the ECAP AGF slope was negatively correlated to the duration of hearing loss and the age at implantation. Since a significant negative correlation of the ECAP AGF slope and age at cochlear implantation and duration of deafness was observed, this study supports the statement that early implantation of a CI is recommended for sensorineural hearing loss. Additional factors such as the cochlear coverage and insertion angle influence the ECAP AGF slope and performance of the patient and should be included in future multifactorial analysis to study predictive parameters for the CI outcome. |
topic |
ECAP AGF slope prognostic factors neuronal function spiral ganglion neurons |
url |
https://www.mdpi.com/2075-1729/11/3/203 |
work_keys_str_mv |
AT lutzgartner correlationofelectricallyevokedcompoundactionpotentialamplitudegrowthfunctionslopeandanamnesticparametersincochlearimplantpatientsidentificationofpredictorsfortheneuronalhealthstatus AT katharinaklotzer correlationofelectricallyevokedcompoundactionpotentialamplitudegrowthfunctionslopeandanamnesticparametersincochlearimplantpatientsidentificationofpredictorsfortheneuronalhealthstatus AT thomaslenarz correlationofelectricallyevokedcompoundactionpotentialamplitudegrowthfunctionslopeandanamnesticparametersincochlearimplantpatientsidentificationofpredictorsfortheneuronalhealthstatus AT verenascheper correlationofelectricallyevokedcompoundactionpotentialamplitudegrowthfunctionslopeandanamnesticparametersincochlearimplantpatientsidentificationofpredictorsfortheneuronalhealthstatus |
_version_ |
1724230055016529920 |