Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis

Abstract Background People with Amyotrophic Lateral Sclerosis (PwALS) in the advanced phase are critically affected by an almost total loss of mobility and severe communication problems. Scanning access based on the patient’s interaction with a sensor (or switch) that intercepts even a weak body mov...

Full description

Bibliographic Details
Main Authors: M. Caligari, M. Godi, M. Giardini, R. Colombo
Format: Article
Language:English
Published: BMC 2019-11-01
Series:Journal of NeuroEngineering and Rehabilitation
Subjects:
Online Access:https://doi.org/10.1186/s12984-019-0626-5
id doaj-3ad824662994444dada88b22ad883958
record_format Article
spelling doaj-3ad824662994444dada88b22ad8839582020-11-29T12:10:32ZengBMCJournal of NeuroEngineering and Rehabilitation1743-00032019-11-0116111310.1186/s12984-019-0626-5Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosisM. Caligari0M. Godi1M. Giardini2R. Colombo3Istituti Clinici Scientifici Maugeri Spa SB (IRCCS), Institute of PaviaIstituti Clinici Scientifici Maugeri Spa SB (IRCCS), Institute of PaviaIstituti Clinici Scientifici Maugeri Spa SB (IRCCS), Institute of VerunoIstituti Clinici Scientifici Maugeri Spa SB (IRCCS), Institute of VerunoAbstract Background People with Amyotrophic Lateral Sclerosis (PwALS) in the advanced phase are critically affected by an almost total loss of mobility and severe communication problems. Scanning access based on the patient’s interaction with a sensor (or switch) that intercepts even a weak body movement is a valid communication aid. However, its use becomes limited with the progressive decline of residual movements. To overcome this problem, we designed a new sensor, the Lever Magnetic-spring Mechanical Switch (LeMMS), allowing repeated activation/release cycles requiring a very small activation force. Methods The LeMMS was applied and validated in a group of 20 PwALS in an advanced stage of disease. All subjects were regular users of communication aids employing other sensors, but which they could no longer operate their sensors (different from LeMMS). Patients were assessed at baseline (t0) and after one (t1), 6 (t2) and 12 (t3) months. Assessment at t0 included administration of standardized clinical scales, the Click-Test-30 counting the maximum number of LeMMS activations in 30 s, and thumb/fingers strength assessment with the Kendall scale. The QUEST 2.0-Dev questionnaire was administered at t1. Some use-related information and the Click-Test-30 were collected at t1, t2 and t3. Results After one training session, all patients could operate the LeMMS with minimal residual movement of one finger. At t1, they used it on average 5.45 h/day. The mean score of the QUEST 2.0-Dev was 4.63, suggesting strong satisfaction with the LeMMS. Regarding Click-Test-30 scores, no significant difference was found between t0 and t1, but performance at t2 and t3 declined significantly (p < 0.005 vs. t0). At t3, 9/20 patients were still able to use their communication aid. Conclusions This new switch sensor can enable PwALS to use their communication aids for a prolonged time even in the advanced phase of disease. It is easy to use, reliable and cheap, thus representing an intermediate alternative to more sophisticated and costly devices.https://doi.org/10.1186/s12984-019-0626-5Augmentative alternative communicationAssistive technologyAmyotrophic lateral sclerosisRehabilitationNeurodegenerative diseasesMotor neuron disease
collection DOAJ
language English
format Article
sources DOAJ
author M. Caligari
M. Godi
M. Giardini
R. Colombo
spellingShingle M. Caligari
M. Godi
M. Giardini
R. Colombo
Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
Journal of NeuroEngineering and Rehabilitation
Augmentative alternative communication
Assistive technology
Amyotrophic lateral sclerosis
Rehabilitation
Neurodegenerative diseases
Motor neuron disease
author_facet M. Caligari
M. Godi
M. Giardini
R. Colombo
author_sort M. Caligari
title Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title_short Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title_full Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title_fullStr Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title_full_unstemmed Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title_sort development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
publisher BMC
series Journal of NeuroEngineering and Rehabilitation
issn 1743-0003
publishDate 2019-11-01
description Abstract Background People with Amyotrophic Lateral Sclerosis (PwALS) in the advanced phase are critically affected by an almost total loss of mobility and severe communication problems. Scanning access based on the patient’s interaction with a sensor (or switch) that intercepts even a weak body movement is a valid communication aid. However, its use becomes limited with the progressive decline of residual movements. To overcome this problem, we designed a new sensor, the Lever Magnetic-spring Mechanical Switch (LeMMS), allowing repeated activation/release cycles requiring a very small activation force. Methods The LeMMS was applied and validated in a group of 20 PwALS in an advanced stage of disease. All subjects were regular users of communication aids employing other sensors, but which they could no longer operate their sensors (different from LeMMS). Patients were assessed at baseline (t0) and after one (t1), 6 (t2) and 12 (t3) months. Assessment at t0 included administration of standardized clinical scales, the Click-Test-30 counting the maximum number of LeMMS activations in 30 s, and thumb/fingers strength assessment with the Kendall scale. The QUEST 2.0-Dev questionnaire was administered at t1. Some use-related information and the Click-Test-30 were collected at t1, t2 and t3. Results After one training session, all patients could operate the LeMMS with minimal residual movement of one finger. At t1, they used it on average 5.45 h/day. The mean score of the QUEST 2.0-Dev was 4.63, suggesting strong satisfaction with the LeMMS. Regarding Click-Test-30 scores, no significant difference was found between t0 and t1, but performance at t2 and t3 declined significantly (p < 0.005 vs. t0). At t3, 9/20 patients were still able to use their communication aid. Conclusions This new switch sensor can enable PwALS to use their communication aids for a prolonged time even in the advanced phase of disease. It is easy to use, reliable and cheap, thus representing an intermediate alternative to more sophisticated and costly devices.
topic Augmentative alternative communication
Assistive technology
Amyotrophic lateral sclerosis
Rehabilitation
Neurodegenerative diseases
Motor neuron disease
url https://doi.org/10.1186/s12984-019-0626-5
work_keys_str_mv AT mcaligari developmentofanewhighsensitivitymechanicalswitchforaugmentativeandalternativecommunicationaccessinpeoplewithamyotrophiclateralsclerosis
AT mgodi developmentofanewhighsensitivitymechanicalswitchforaugmentativeandalternativecommunicationaccessinpeoplewithamyotrophiclateralsclerosis
AT mgiardini developmentofanewhighsensitivitymechanicalswitchforaugmentativeandalternativecommunicationaccessinpeoplewithamyotrophiclateralsclerosis
AT rcolombo developmentofanewhighsensitivitymechanicalswitchforaugmentativeandalternativecommunicationaccessinpeoplewithamyotrophiclateralsclerosis
_version_ 1724412099776479232