Kinetics and seroprevalence of SARS-CoV-2 antibodies: a comparison of 3 different assays

Abstract Comparing seroprevalence and antibody kinetics in three different commercially available assays for SARS-CoV-2. Serostatus of COVID-19 patients was analyzed 5 months and 10 months after their infection, using three different assays: Diasorin LIAISON, Euroimmun, Abbott Diagnostics ARCHITECT....

Full description

Bibliographic Details
Main Authors: Elisabeth Kahre, Lukas Galow, Manja Unrath, Luise Haag, Judith Blankenburg, Alexander H. Dalpke, Christian Lück, Reinhard Berner, Jakob P. Armann
Format: Article
Language:English
Published: Nature Publishing Group 2021-07-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-021-94453-5
id doaj-3ad06cb755d9481f99002db848a9c614
record_format Article
spelling doaj-3ad06cb755d9481f99002db848a9c6142021-07-25T11:27:24ZengNature Publishing GroupScientific Reports2045-23222021-07-011111610.1038/s41598-021-94453-5Kinetics and seroprevalence of SARS-CoV-2 antibodies: a comparison of 3 different assaysElisabeth Kahre0Lukas Galow1Manja Unrath2Luise Haag3Judith Blankenburg4Alexander H. Dalpke5Christian Lück6Reinhard Berner7Jakob P. Armann8Department of Pediatrics, University Hospital and Medical Faculty Carl Gustav Carus, Technische Universität DresdenDepartment of Pediatrics, University Hospital and Medical Faculty Carl Gustav Carus, Technische Universität DresdenDepartment of Pediatrics, University Hospital and Medical Faculty Carl Gustav Carus, Technische Universität DresdenDepartment of Pediatrics, University Hospital and Medical Faculty Carl Gustav Carus, Technische Universität DresdenDepartment of Pediatrics, University Hospital and Medical Faculty Carl Gustav Carus, Technische Universität DresdenMedical Faculty Carl Gustav Carus, Institute for Medical Microbiology and Virology, Technische Universität DresdenMedical Faculty Carl Gustav Carus, Institute for Medical Microbiology and Virology, Technische Universität DresdenDepartment of Pediatrics, University Hospital and Medical Faculty Carl Gustav Carus, Technische Universität DresdenDepartment of Pediatrics, University Hospital and Medical Faculty Carl Gustav Carus, Technische Universität DresdenAbstract Comparing seroprevalence and antibody kinetics in three different commercially available assays for SARS-CoV-2. Serostatus of COVID-19 patients was analyzed 5 months and 10 months after their infection, using three different assays: Diasorin LIAISON, Euroimmun, Abbott Diagnostics ARCHITECT. Seropositivity at baseline differed significantly depending on the assay (Diasorin 81%, Euroimmun 83%, Abbott 59%). At follow-up antibody levels detected in the Diasorin assay were stable, while there was a significant loss in seropositivity in the Euroimmun and Abbott assays. There are significant differences in SARS-CoV-2 antibody kinetics based on the specific assay used.https://doi.org/10.1038/s41598-021-94453-5
collection DOAJ
language English
format Article
sources DOAJ
author Elisabeth Kahre
Lukas Galow
Manja Unrath
Luise Haag
Judith Blankenburg
Alexander H. Dalpke
Christian Lück
Reinhard Berner
Jakob P. Armann
spellingShingle Elisabeth Kahre
Lukas Galow
Manja Unrath
Luise Haag
Judith Blankenburg
Alexander H. Dalpke
Christian Lück
Reinhard Berner
Jakob P. Armann
Kinetics and seroprevalence of SARS-CoV-2 antibodies: a comparison of 3 different assays
Scientific Reports
author_facet Elisabeth Kahre
Lukas Galow
Manja Unrath
Luise Haag
Judith Blankenburg
Alexander H. Dalpke
Christian Lück
Reinhard Berner
Jakob P. Armann
author_sort Elisabeth Kahre
title Kinetics and seroprevalence of SARS-CoV-2 antibodies: a comparison of 3 different assays
title_short Kinetics and seroprevalence of SARS-CoV-2 antibodies: a comparison of 3 different assays
title_full Kinetics and seroprevalence of SARS-CoV-2 antibodies: a comparison of 3 different assays
title_fullStr Kinetics and seroprevalence of SARS-CoV-2 antibodies: a comparison of 3 different assays
title_full_unstemmed Kinetics and seroprevalence of SARS-CoV-2 antibodies: a comparison of 3 different assays
title_sort kinetics and seroprevalence of sars-cov-2 antibodies: a comparison of 3 different assays
publisher Nature Publishing Group
series Scientific Reports
issn 2045-2322
publishDate 2021-07-01
description Abstract Comparing seroprevalence and antibody kinetics in three different commercially available assays for SARS-CoV-2. Serostatus of COVID-19 patients was analyzed 5 months and 10 months after their infection, using three different assays: Diasorin LIAISON, Euroimmun, Abbott Diagnostics ARCHITECT. Seropositivity at baseline differed significantly depending on the assay (Diasorin 81%, Euroimmun 83%, Abbott 59%). At follow-up antibody levels detected in the Diasorin assay were stable, while there was a significant loss in seropositivity in the Euroimmun and Abbott assays. There are significant differences in SARS-CoV-2 antibody kinetics based on the specific assay used.
url https://doi.org/10.1038/s41598-021-94453-5
work_keys_str_mv AT elisabethkahre kineticsandseroprevalenceofsarscov2antibodiesacomparisonof3differentassays
AT lukasgalow kineticsandseroprevalenceofsarscov2antibodiesacomparisonof3differentassays
AT manjaunrath kineticsandseroprevalenceofsarscov2antibodiesacomparisonof3differentassays
AT luisehaag kineticsandseroprevalenceofsarscov2antibodiesacomparisonof3differentassays
AT judithblankenburg kineticsandseroprevalenceofsarscov2antibodiesacomparisonof3differentassays
AT alexanderhdalpke kineticsandseroprevalenceofsarscov2antibodiesacomparisonof3differentassays
AT christianluck kineticsandseroprevalenceofsarscov2antibodiesacomparisonof3differentassays
AT reinhardberner kineticsandseroprevalenceofsarscov2antibodiesacomparisonof3differentassays
AT jakobparmann kineticsandseroprevalenceofsarscov2antibodiesacomparisonof3differentassays
_version_ 1721283167393939456