Poor glycemic control attributable to insulin antibody in a fulminant type 1 diabetes patient under hemodialysis: successful treatment with double filtration plasmapheresis and prednisolone

Abstract Background Insulin antibody appears in approximately 40% of insulin users using human insulin and insulin analog formulations. Insulin antibody, characterized by high affinity and low insulin antibody binding capacity (% bound), rarely causes clinical problems including poor glycemic contro...

Full description

Bibliographic Details
Main Authors: Kentaro Wada, Haruhito A. Uchida, Yuko Wada
Format: Article
Language:English
Published: BMC 2017-04-01
Series:Renal Replacement Therapy
Subjects:
Online Access:http://link.springer.com/article/10.1186/s41100-017-0096-9
id doaj-3a4ae5ca12cc46c69db96f0135da1a3f
record_format Article
spelling doaj-3a4ae5ca12cc46c69db96f0135da1a3f2020-11-25T00:35:18ZengBMCRenal Replacement Therapy2059-13812017-04-01311710.1186/s41100-017-0096-9Poor glycemic control attributable to insulin antibody in a fulminant type 1 diabetes patient under hemodialysis: successful treatment with double filtration plasmapheresis and prednisoloneKentaro Wada0Haruhito A. Uchida1Yuko Wada2Division of Nephrology and Dialysis, Department of Internal Medicine, Nippon Kokan Fukuyama HospitalDepartment of Chronic Kidney Disease and Cardiovascular Disease, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical SciencesDivision of Nephrology and Dialysis, Department of Internal Medicine, Central HospitalAbstract Background Insulin antibody appears in approximately 40% of insulin users using human insulin and insulin analog formulations. Insulin antibody, characterized by high affinity and low insulin antibody binding capacity (% bound), rarely causes clinical problems including poor glycemic control. Recently, the insulin antibody against human insulin causing deterioration of glycemic control, characterized by low affinity and high insulin antibody binding capacity similar to those observed in insulin autoimmune syndrome, has been reported. Case presentation A 62-year-old male developing fulminant type 1 diabetes showing rapid hyperglycemia (602 mg/dL) and normal range of glycoalbumin (GA) (18.4%) in the introductory stage of hemodialysis (HD) was transferred to our hospital 3 weeks after the onset of diabetes. He had been administered insulin intensification therapy in other medical clinic; however, his glycemic control remained poor, showing ketoacidosis. After hospitalization, he was initially administered intravenous insulin for 2 days and then switched to subcutaneous intensification therapy (24 U/day); the dose was gradually increased maximum of 72 U/day within 2 months. His glycemic control deteriorated despite high-dose insulin administration and change in the insulin type. Insulin antibody was detected, insulin antibody binding capacity (% bound) was of a high value (89.5%), GA was 32.9%, and casual blood glucose widely changed in continuous glucose monitor, suggesting that unstable blood glucose fluctuations caused by insulin antibody; therefore, treatment with double filtration plasmapheresis (DFPP) and prednisolone (PSL) was performed. The insulin dose reduced, and glycemic control improved from 1 month after the commencement of treatment. Subsequently, insulin antibody level remained high; however, after 6 months, % bound declined (20.9%), and glycemic control improved (GA 23.7%) by PSL (gradually reduced to 5 mg/day). The Scatchard plots also indicated the effectiveness with DFPP and PSL therapy. Conclusions The authors present a unique case of fulminant type 1 diabetes developing during the HD introduction period. Although this is a rare complication, physicians specializing in dialysis therapy should also keep in mind that this is a life-threatening complication if the treatment is delayed and that concomitant therapy with apheresis such as DFPP and long-term steroids is effective in some cases when glycemic control deteriorates attributable to insulin antibody.http://link.springer.com/article/10.1186/s41100-017-0096-9Insulin antibodyInsulin antibody binding capacityFulminant type 1 diabetesHemodialysisDouble filtration plasmapheresisPrednisolone
collection DOAJ
language English
format Article
sources DOAJ
author Kentaro Wada
Haruhito A. Uchida
Yuko Wada
spellingShingle Kentaro Wada
Haruhito A. Uchida
Yuko Wada
Poor glycemic control attributable to insulin antibody in a fulminant type 1 diabetes patient under hemodialysis: successful treatment with double filtration plasmapheresis and prednisolone
Renal Replacement Therapy
Insulin antibody
Insulin antibody binding capacity
Fulminant type 1 diabetes
Hemodialysis
Double filtration plasmapheresis
Prednisolone
author_facet Kentaro Wada
Haruhito A. Uchida
Yuko Wada
author_sort Kentaro Wada
title Poor glycemic control attributable to insulin antibody in a fulminant type 1 diabetes patient under hemodialysis: successful treatment with double filtration plasmapheresis and prednisolone
title_short Poor glycemic control attributable to insulin antibody in a fulminant type 1 diabetes patient under hemodialysis: successful treatment with double filtration plasmapheresis and prednisolone
title_full Poor glycemic control attributable to insulin antibody in a fulminant type 1 diabetes patient under hemodialysis: successful treatment with double filtration plasmapheresis and prednisolone
title_fullStr Poor glycemic control attributable to insulin antibody in a fulminant type 1 diabetes patient under hemodialysis: successful treatment with double filtration plasmapheresis and prednisolone
title_full_unstemmed Poor glycemic control attributable to insulin antibody in a fulminant type 1 diabetes patient under hemodialysis: successful treatment with double filtration plasmapheresis and prednisolone
title_sort poor glycemic control attributable to insulin antibody in a fulminant type 1 diabetes patient under hemodialysis: successful treatment with double filtration plasmapheresis and prednisolone
publisher BMC
series Renal Replacement Therapy
issn 2059-1381
publishDate 2017-04-01
description Abstract Background Insulin antibody appears in approximately 40% of insulin users using human insulin and insulin analog formulations. Insulin antibody, characterized by high affinity and low insulin antibody binding capacity (% bound), rarely causes clinical problems including poor glycemic control. Recently, the insulin antibody against human insulin causing deterioration of glycemic control, characterized by low affinity and high insulin antibody binding capacity similar to those observed in insulin autoimmune syndrome, has been reported. Case presentation A 62-year-old male developing fulminant type 1 diabetes showing rapid hyperglycemia (602 mg/dL) and normal range of glycoalbumin (GA) (18.4%) in the introductory stage of hemodialysis (HD) was transferred to our hospital 3 weeks after the onset of diabetes. He had been administered insulin intensification therapy in other medical clinic; however, his glycemic control remained poor, showing ketoacidosis. After hospitalization, he was initially administered intravenous insulin for 2 days and then switched to subcutaneous intensification therapy (24 U/day); the dose was gradually increased maximum of 72 U/day within 2 months. His glycemic control deteriorated despite high-dose insulin administration and change in the insulin type. Insulin antibody was detected, insulin antibody binding capacity (% bound) was of a high value (89.5%), GA was 32.9%, and casual blood glucose widely changed in continuous glucose monitor, suggesting that unstable blood glucose fluctuations caused by insulin antibody; therefore, treatment with double filtration plasmapheresis (DFPP) and prednisolone (PSL) was performed. The insulin dose reduced, and glycemic control improved from 1 month after the commencement of treatment. Subsequently, insulin antibody level remained high; however, after 6 months, % bound declined (20.9%), and glycemic control improved (GA 23.7%) by PSL (gradually reduced to 5 mg/day). The Scatchard plots also indicated the effectiveness with DFPP and PSL therapy. Conclusions The authors present a unique case of fulminant type 1 diabetes developing during the HD introduction period. Although this is a rare complication, physicians specializing in dialysis therapy should also keep in mind that this is a life-threatening complication if the treatment is delayed and that concomitant therapy with apheresis such as DFPP and long-term steroids is effective in some cases when glycemic control deteriorates attributable to insulin antibody.
topic Insulin antibody
Insulin antibody binding capacity
Fulminant type 1 diabetes
Hemodialysis
Double filtration plasmapheresis
Prednisolone
url http://link.springer.com/article/10.1186/s41100-017-0096-9
work_keys_str_mv AT kentarowada poorglycemiccontrolattributabletoinsulinantibodyinafulminanttype1diabetespatientunderhemodialysissuccessfultreatmentwithdoublefiltrationplasmapheresisandprednisolone
AT haruhitoauchida poorglycemiccontrolattributabletoinsulinantibodyinafulminanttype1diabetespatientunderhemodialysissuccessfultreatmentwithdoublefiltrationplasmapheresisandprednisolone
AT yukowada poorglycemiccontrolattributabletoinsulinantibodyinafulminanttype1diabetespatientunderhemodialysissuccessfultreatmentwithdoublefiltrationplasmapheresisandprednisolone
_version_ 1725309117370728448