Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches

Introduction. Blood pressure (BP) has been a potential risk factor for cardiovascular diseases. BP measurement is one of the most useful parameters for early diagnosis, prevention, and treatment of cardiovascular diseases. At present, BP measurement mainly relies on cuff-based techniques that cause...

Full description

Bibliographic Details
Main Authors: Syed Ghufran Khalid, Jufen Zhang, Fei Chen, Dingchang Zheng
Format: Article
Language:English
Published: Hindawi Limited 2018-01-01
Series:Journal of Healthcare Engineering
Online Access:http://dx.doi.org/10.1155/2018/1548647
id doaj-3a280c0f9d3b4b04975ec84ad81d585a
record_format Article
spelling doaj-3a280c0f9d3b4b04975ec84ad81d585a2020-11-25T01:31:18ZengHindawi LimitedJournal of Healthcare Engineering2040-22952040-23092018-01-01201810.1155/2018/15486471548647Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning ApproachesSyed Ghufran Khalid0Jufen Zhang1Fei Chen2Dingchang Zheng3Faculty of Medical Science, Anglia Ruskin University, Bishop Hall Ln, Chelmsford CM11SQ, UKFaculty of Medical Science, Anglia Ruskin University, Bishop Hall Ln, Chelmsford CM11SQ, UKDepartment of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen 518055, ChinaFaculty of Medical Science, Anglia Ruskin University, Bishop Hall Ln, Chelmsford CM11SQ, UKIntroduction. Blood pressure (BP) has been a potential risk factor for cardiovascular diseases. BP measurement is one of the most useful parameters for early diagnosis, prevention, and treatment of cardiovascular diseases. At present, BP measurement mainly relies on cuff-based techniques that cause inconvenience and discomfort to users. Although some of the present prototype cuffless BP measurement techniques are able to reach overall acceptable accuracies, they require an electrocardiogram (ECG) and a photoplethysmograph (PPG) that make them unsuitable for true wearable applications. Therefore, developing a single PPG-based cuffless BP estimation algorithm with enough accuracy would be clinically and practically useful. Methods. The University of Queensland vital sign dataset (online database) was accessed to extract raw PPG signals and its corresponding reference BPs (systolic BP and diastolic BP). The online database consisted of PPG waveforms of 32 cases from whom 8133 (good quality) signal segments (5 s for each) were extracted, preprocessed, and normalised in both width and amplitude. Three most significant pulse features (pulse area, pulse rising time, and width 25%) with their corresponding reference BPs were used to train and test three machine learning algorithms (regression tree, multiple linear regression (MLR), and support vector machine (SVM)). A 10-fold cross-validation was applied to obtain overall BP estimation accuracy, separately for the three machine learning algorithms. Their estimation accuracies were further analysed separately for three clinical BP categories (normotensive, hypertensive, and hypotensive). Finally, they were compared with the ISO standard for noninvasive BP device validation (average difference no greater than 5 mmHg and SD no greater than 8 mmHg). Results. In terms of overall estimation accuracy, the regression tree achieved the best overall accuracy for SBP (mean and SD of difference: −0.1 ± 6.5 mmHg) and DBP (mean and SD of difference: −0.6 ± 5.2 mmHg). MLR and SVM achieved the overall mean difference less than 5 mmHg for both SBP and DBP, but their SD of difference was >8 mmHg. Regarding the estimation accuracy in each BP categories, only the regression tree achieved acceptable ISO standard for SBP (−1.1 ± 5.7 mmHg) and DBP (−0.03 ± 5.6 mmHg) in the normotensive category. MLR and SVM did not achieve acceptable accuracies in any BP categories. Conclusion. This study developed and compared three machine learning algorithms to estimate BPs using PPG only and revealed that the regression tree algorithm was the best approach with overall acceptable accuracy to ISO standard for BP device validation. Furthermore, this study demonstrated that the regression tree algorithm achieved acceptable measurement accuracy only in the normotensive category, suggesting that future algorithm development for BP estimation should be more specific for different BP categories.http://dx.doi.org/10.1155/2018/1548647
collection DOAJ
language English
format Article
sources DOAJ
author Syed Ghufran Khalid
Jufen Zhang
Fei Chen
Dingchang Zheng
spellingShingle Syed Ghufran Khalid
Jufen Zhang
Fei Chen
Dingchang Zheng
Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
Journal of Healthcare Engineering
author_facet Syed Ghufran Khalid
Jufen Zhang
Fei Chen
Dingchang Zheng
author_sort Syed Ghufran Khalid
title Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title_short Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title_full Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title_fullStr Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title_full_unstemmed Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title_sort blood pressure estimation using photoplethysmography only: comparison between different machine learning approaches
publisher Hindawi Limited
series Journal of Healthcare Engineering
issn 2040-2295
2040-2309
publishDate 2018-01-01
description Introduction. Blood pressure (BP) has been a potential risk factor for cardiovascular diseases. BP measurement is one of the most useful parameters for early diagnosis, prevention, and treatment of cardiovascular diseases. At present, BP measurement mainly relies on cuff-based techniques that cause inconvenience and discomfort to users. Although some of the present prototype cuffless BP measurement techniques are able to reach overall acceptable accuracies, they require an electrocardiogram (ECG) and a photoplethysmograph (PPG) that make them unsuitable for true wearable applications. Therefore, developing a single PPG-based cuffless BP estimation algorithm with enough accuracy would be clinically and practically useful. Methods. The University of Queensland vital sign dataset (online database) was accessed to extract raw PPG signals and its corresponding reference BPs (systolic BP and diastolic BP). The online database consisted of PPG waveforms of 32 cases from whom 8133 (good quality) signal segments (5 s for each) were extracted, preprocessed, and normalised in both width and amplitude. Three most significant pulse features (pulse area, pulse rising time, and width 25%) with their corresponding reference BPs were used to train and test three machine learning algorithms (regression tree, multiple linear regression (MLR), and support vector machine (SVM)). A 10-fold cross-validation was applied to obtain overall BP estimation accuracy, separately for the three machine learning algorithms. Their estimation accuracies were further analysed separately for three clinical BP categories (normotensive, hypertensive, and hypotensive). Finally, they were compared with the ISO standard for noninvasive BP device validation (average difference no greater than 5 mmHg and SD no greater than 8 mmHg). Results. In terms of overall estimation accuracy, the regression tree achieved the best overall accuracy for SBP (mean and SD of difference: −0.1 ± 6.5 mmHg) and DBP (mean and SD of difference: −0.6 ± 5.2 mmHg). MLR and SVM achieved the overall mean difference less than 5 mmHg for both SBP and DBP, but their SD of difference was >8 mmHg. Regarding the estimation accuracy in each BP categories, only the regression tree achieved acceptable ISO standard for SBP (−1.1 ± 5.7 mmHg) and DBP (−0.03 ± 5.6 mmHg) in the normotensive category. MLR and SVM did not achieve acceptable accuracies in any BP categories. Conclusion. This study developed and compared three machine learning algorithms to estimate BPs using PPG only and revealed that the regression tree algorithm was the best approach with overall acceptable accuracy to ISO standard for BP device validation. Furthermore, this study demonstrated that the regression tree algorithm achieved acceptable measurement accuracy only in the normotensive category, suggesting that future algorithm development for BP estimation should be more specific for different BP categories.
url http://dx.doi.org/10.1155/2018/1548647
work_keys_str_mv AT syedghufrankhalid bloodpressureestimationusingphotoplethysmographyonlycomparisonbetweendifferentmachinelearningapproaches
AT jufenzhang bloodpressureestimationusingphotoplethysmographyonlycomparisonbetweendifferentmachinelearningapproaches
AT feichen bloodpressureestimationusingphotoplethysmographyonlycomparisonbetweendifferentmachinelearningapproaches
AT dingchangzheng bloodpressureestimationusingphotoplethysmographyonlycomparisonbetweendifferentmachinelearningapproaches
_version_ 1725087447375675392